JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Doneley, S.
Right arrow Articles by von Goedecke, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Doneley, S.
Right arrow Articles by von Goedecke, A.

Anesth Analg 2005;100:590-593
© 2005 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000144068.26632.B7


GENERAL ARTICLES

The ProSealTM Has a Shorter Life-Span than the ClassicTM Laryngeal Mask Airway

Sarah Doneley, MB BS*, Joseph Brimacombe, MB ChB, FRCA, MD{dagger}, Christian Keller, MD{ddagger}, and Achim von Goedecke, MD{ddagger}

*Department of Anaesthesia and Intensive Care, Cairns Base Hospital, Australia; {dagger}James Cook University, Department of Anaesthesia and Intensive Care, Cairns Base Hospital, Australia; {ddagger}Department of Anaesthesia and Intensive Care Medicine, Leopold-Franzens University, Innsbruck, Austria

We tested the hypothesis that the life-span of the ProSealTM laryngeal mask airway (LMA) is shorter than the ClassicTM LMA. We also compared residual cuff volumes and changes in elastance and permeability with use. Six new size 4 ProSealTM LMAs and 6 new size 4 ClassicTM LMAs were tested. Each LMA underwent a simulated clinical use cycle until it failed the pre-use check tests. The simulated clinical use cycle comprised: i) inflating the cuff to the maximum recommended volume for 1 h; ii) immersion in an enzymatic solution for 3 min; iii) washing the external and internal surfaces; iv) automatic washing for 14 min (≤85°C); v) drying for 30 min (≤75°C); and vi) autoclaving at 134°C for 4 min at 206 kPa. Before the first cycle and every 10 subsequent cycles, the cuff was inflated with 40 mL air and the intracuff pressure was measured immediately and 3 h later. The initial intracuff pressure was taken to be an inverse measure of the elastance or resistance to deformation, and the intracuff pressure change were taken as a measure of the permeability. The residual cuff volume was determined for 10 ClassicTM and 10 ProSealTM size 4 LMAs using a gas dilution technique. The mean ± sd (range) longevity for the ProSealTM LMA and ClassicTM LMA was 82 ± 23 (45–109) uses and 133 ± 35 (76–176) uses, respectively. The ProSealTM LMA has a shorter life-span than the ClassicTM LMA (P = 0.01). For the ProSealTM LMA, there was no change in elastance or permeability with use. For the ClassicTM LMA, there was a decrease in elastance (P < 0.0001) and an increase in permeability (P < 0.0001) with use. The residual cuff volume was higher for the ProSealTM LMA (2.6 ± 1.3 mL versus 1.5 ± 0.9, P = 0.04). We conclude that the life-span of the ProSealTM LMA is shorter than the ClassicTM LMA, but both exceed the manufacturer’s recommendations of 40 uses. We recommend that reusable LMA devices be discarded when they fail the pre-use check tests, rather than after a specific number of uses.




This article has been cited by other articles:


Home page
Br J AnaesthHome page
T. M. Cook
Editorial I: The classic laryngeal mask airway: a tried and tested airway. What now?
Br. J. Anaesth., February 1, 2006; 96(2): 149 - 152.
[Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2005 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press