JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hallworth, S. P.
Right arrow Articles by Stocks, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hallworth, S. P.
Right arrow Articles by Stocks, G. M.
Related Collections
Right arrow Obstetrics
Right arrow Regional Anesthesia

Anesth Analg 2005;100:1159-1165
© 2005 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000149548.88029.A2


OBSTETRIC ANESTHESIA

The Effect of Posture and Baricity on the Spread of Intrathecal Bupivacaine for Elective Cesarean Delivery

Stephen P. Hallworth, FRCA*, Roshan Fernando, FRCA*, Malachy O. Columb, FRCA{dagger}, and Gary M. Stocks, FRCA*

*Department of Anesthetics, Royal Free Hospital, London, and {dagger}Department of Anesthesia and Intensive Medicine, South Manchester University Hospital, Wythenshawe, United Kingdom

Address correspondence and reprint requests to Roshan Fernando, FRCA, Department of Anesthetics, Royal Free Hospital, Pond Street, London NW3 2QG, United Kingdom. Address e-mail to r.fernando{at}btinternet.com.

Posture and baricity during induction of spinal anesthesia with intrathecal drugs are believed to be important in determining spread within the cerebrospinal fluid. In this double-blind prospective study, 150 patients undergoing elective cesarean delivery were randomized to receive a hyperbaric, isobaric, or hypobaric intrathecal solution of 10 mg bupivacaine during spinal anesthesia induced in either the sitting or right lateral position. After an intrathecal injection using a combined-spinal technique patients were placed in the supine wedged position. We determined the densities of the three intrathecal solutions from a previously validated formula and measured using a DMA-450 density meter. Data collection included sensory level, motor block, episodes of hypotension, and ephedrine use. Statistical analysis included analysis of variance and Cuzick’s trend. In the lateral position, baricity had no effect on the spread of sensory levels for bupivacaine compared to the sitting position, where there was a statistically significant difference in spread with the hypobaric solution producing higher levels of analgesia than the hyperbaric solution (P = 0.002). However, the overall differences in maximal spread only differed by one dermatome, with the hyperbaric solution achieving a median maximum sensory level to T3 compared with T2 for the isobaric and hypobaric solutions. Motor block was significantly (P = 0.029) reduced with increasing baricity and this trend was significant (P = 0.033) for the lateral position only. Hypotension incidence and ephedrine use increased with decreasing baricity (P = 0.003 and 0.004 respectively), with the hypobaric sitting group having the most frequent incidence of hypotension (76%) as well as cervical blocks (24%; P = 0.032).







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2005 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2005 by the International Anesthesia Research Society.