JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsui, B. C. H.
Right arrow Articles by Sze, C. K. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsui, B. C. H.
Right arrow Articles by Sze, C. K. C.
Related Collections
Right arrow Equipment
Right arrow Anesthetic Techniques
Right arrow Regional Anesthesia
Right arrow Pharmacology

Anesth Analg 2005;101:1528-1530
© 2005 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000181006.36917.3E


REGIONAL ANESTHESIA

An In Vitro Comparison of the Electrical Conducting Properties of Multiport Versus Single-Port Epidural Catheters for the Epidural Stimulation Test

Ban C. H. Tsui, MD, MSc, FRCP*, and Corey K. C. Sze{dagger}

*Department of Anesthesiology and Pain Medicine, University of Alberta, Edmonton, Alberta, Canada; {dagger}Faculty of Engineering, University of Alberta, Edmonton, Alberta, Canada

Address correspondence and reprint requests to Ban C.H. Tsui, MSC, MD, FRCP(C), Department of Anesthesiology and Pain Medicine, 8–120 Clinical Sciences Building, University of Alberta, Edmonton, Alberta, Canada T6G 2G3. Address electronic mail to btsui{at}ualberta.ca.

Effective conduction of electricity through a catheter is essential for the success of the epidural stimulation test. In this in vitro study we examined the electrical conductivity of single and multiport epidural catheters (with and without embedded metal elements) after being primed with normal saline. Seven different types of 19-gauge catheters (n = 5), either single-port or multiport catheters, with or without embedded metal elements, were studied. The proximal end of each epidural catheter was connected to the cathode of a nerve stimulator via an electrode adapter. The catheter, primed with normal saline, was placed at the bottom of a syringe filled with 5 different volumes of saline (1, 2, 3, 4 and 5 mL) and attached to an electrode adapter. The voltage of the peripheral nerve stimulator was measured using an oscilloscope. The electrical resistance between the proximal and distal end of the catheter was calculated using Ohm’s Law. In catheters without metal elements the electrical resistances were too high to be measured. In catheters that had metal elements, the mean electrical resistances of the same catheter design (single-port or multiport) were similar. However, the electrical resistances of the multiport metal reinforced epidural catheters were significantly lower (P < 0.05) than the single-port metal coil reinforced epidural catheters. The volume of saline in the syringe had no impact on the measured electrical resistances. This study suggests that multiport metal reinforced epidural catheters have low electrical resistances and, thus, are a reasonable alternative to single-port catheters for transmitting sufficient current for performing the epidural stimulation test. On the other hand, epidural catheters without metal elements (single-port or multiport) are not suitable for performing the stimulation test.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2005 by the International Anesthesia Research Society.