JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sawai, T.
Right arrow Articles by Kuro, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sawai, T.
Right arrow Articles by Kuro, M.
Related Collections
Right arrow Cardiovascular
Right arrow Heart
Right arrow Monitoring (Cardiac)

Anesth Analg 2005;101:1597-1601
© 2005 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000180765.39501.42


CARDIOVASCULAR ANESTHESIA

Cardiac Output Measurement Using the Transesophageal Doppler Method Is Less Accurate Than the Thermodilution Method When Changing Paco2

Toshiyuki Sawai, MD, Toshihiro Nohmi, MD, Yoshihiko Ohnishi, MD, Yuji Takauchi, MD, and Masakazu Kuro, MD, PhD

Department of Anesthesiology, Osaka Medical College, Takatsuki, Japan; Department of Anesthesia, National Cardiovascular Center, Suita, Japan

Address correspondence and reprint requests to Toshiyuki Sawai, MD, Department of Anesthesiology, Osaka Medical College, 2–7 Daigaku-machi, Takatsuki 569–8686, Japan. Address e-mail to ane026{at}poh.osaka-med.ac.jp.

Cardiac output (CO) determination using transesophageal Doppler is based on the measurement of descending aortic blood flow. Because cerebral blood flow is dependent on Paco2, an increase in Paco2 would result in an increase of CO because of the increase in cerebral blood flow and vice versa. We enrolled 30 patients undergoing off-pump coronary artery graft surgery in the study. The CO was determined by both transesophageal Doppler and thermodilution while Paco2 was maintained at either 30 mm Hg or 40 mm Hg in random order. The CO by thermodilution was significantly higher at Paco2 of 40 mm Hg (4.17 ± 0.94 L/min) than at 30 mm Hg (3.78 ± 0.85 L/min). On the other hand, there were no significant differences in CO by transesophageal Doppler: 3.85 ± 0.76 L/min at Paco2 of 40 mm Hg and 3.77 ± 0.74 at 30 mm Hg. Bland-Altman analysis yielded bias and precision of –0.32 and 0.49 L/min at Paco2 of 40 mm Hg, and –0.01 and 0.34 L/min at 30 mm Hg. These results indicate that both methods of CO measurement are in agreement at 30 mm Hg of Paco2, but the thermodilution method provides higher values at 40 mm Hg of Paco2.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press