JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goldmann, K.
Right arrow Articles by Wulf, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldmann, K.
Right arrow Articles by Wulf, H.

Anesth Analg 2006;102:405-410
© 2006 International Anesthesia Research Society
doi: 10.1213/01.ane.0000194300.56739.1a


PEDIATRIC ANESTHESIA

The Size 11/2 ProSealTM Laryngeal Mask Airway in Infants: A Randomized, Crossover Investigation with the ClassicTM Laryngeal Mask Airway

Kai Goldmann, MD, DEAA, Christine Roettger, FW, and Hinnerk Wulf, MD

Department of Anaesthesia and Intensive Care Therapy, Philipps University Marburg, Germany

Address correspondence and reprint requests to Kai Goldmann, MD, DEAA, Attending Anesthesiologist, Department of Anaesthesia and Intensive Care Therapy, Philipps University Marburg, 35033 Marburg, Germany. Address e-mail to Kaigoldmann1{at}aol.com.

Many problems with the ClassicTM laryngeal mask airway (CLMA) in infants are believed to be related to its inadequate cuff design. One of the main limitations of the CLMA is that the resulting low-pressure seal can be inadequate for positive pressure ventilation (PPV). The ProSealTM LMA (PLMA), a new laryngeal mask airway with a modified cuff, has been shown to form a more effective seal than the CLMA in children. The first infant size PLMA, size 11/2, became available recently. We studied 30 anesthetized, nonparalyzed infants aged 15 mo (2–30 mo) and weighing 9 kg (5–12 kg). The CLMA and PLMA were inserted in random order into each patient. Airway leak pressure and maximum tidal volume were measured. Ease of insertion, quality of initial airway, and fiberoptic position were also determined. Gastric tube placement was assessed for the PLMA. The mean airway leak pressure in neutral head position (26.7 versus 18.9 cm H2O), maximum flexion (35.6 versus 28.2 cm H2O), and the mean maximum tidal volume (312 versus 260 mL) were significantly higher for the PLMA (P < 0.01). Air entered the stomach in eight patients with the CLMA but did not with the PLMA. Gastric tube placement was possible in all but one patient. In three patients, the use of the PLMA led to some degree of clinically relevant compression of the larynx. The size 11/2 PLMA seems to be a more suitable device for airway maintenance in infants than the same size CLMA. The ability to insert a gastric tube at the same time, and a significantly higher airway leak pressure than with the CLMA, may have important implications for its use for PPV in infants.




This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
D. R. R. Lardner, R. G. Cox, A. Ewen, and D. Dickinson
Comparison of laryngeal mask airway (LMA)- ProsealTM and the LMA-ClassicTM in ventilated children receiving neuromuscular blockade: [Comparaison entre les masques larynges (LMA)-ProSealTM et LMA-ClassicTM chez les enfants ventiles lors d'un bloc neuromusculaire]
Can J Anesth, January 1, 2008; 55(1): 29 - 35.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Micaglio, M. Parotto, D. Trevisanuto, and V. Zanardo
Size 1 ProSealTM Laryngeal Mask Airway in Neonates
Anesth. Analg., October 1, 2006; 103(4): 1044 - 1045.
[Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2006 by the International Anesthesia Research Society.