JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lovich, M. A.
Right arrow Articles by Peterfreund, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lovich, M. A.
Right arrow Articles by Peterfreund, R. A.
Related Collections
Right arrow Technology
Right arrow Pharmacology

Anesth Analg 2006;102:1147-1153
© 2006 International Anesthesia Research Society
doi: 10.1213/01.ane.0000198670.02481.6b


TECHNOLOGY, COMPUTING, AND SIMULATION

The Delivery of Drugs to Patients by Continuous Intravenous Infusion: Modeling Predicts Potential Dose Fluctuations Depending on Flow Rates and Infusion System Dead Volume

Mark A. Lovich, MD, PhD*, M. Ellen Kinnealley, RN{dagger}, Nathanial M. Sims, MD*{dagger}, and Robert A. Peterfreund, MD, PhD*

Departments of *Anesthesia and Critical Care and {dagger}Biomedical Engineering, Massachusetts General Hospital, Boston

Address correspondence and reprint requests to Mark A. Lovich, MD, PhD, Department of Anesthesia and Critical Care, Massachusetts General Hospital, 55 Fruit St., Boston, MA 02114. Address e-mail to mlovich{at}partners.org.

IV drug infusion has the potential for dosing errors, which arise from complex interactions between carrier flows and the infusion set dead volume. We computed the steady-state mass of drug stored in the infusion set dead volume, using phenylephrine as a model compound. The mass of drug in the dead volume increases with stock drug concentration and desired dose but decreases with carrier flow rate. We also modeled the dynamic perturbations in drug delivery when a carrier is abruptly stopped. Rapid initial carrier flow rates lead to greater depression in drug delivery rate after carrier flow ceases. Rapid drug infusion rates lead to faster restoration of desired drug delivery. Finally, the time to reach a new steady-state after a change in drug delivery or carrier rate was computed. This time is longest for large stock-drug concentrations, larger dead volumes, and slower final carrier rates. These computations illustrate that (a) the dead volume may contain a large mass of drug available for inadvertent bolus, (b) cessation of carrier flow can profoundly reduce drug delivery, and (c) after a change in carrier flow or drug dosing, a significant lag is possible before drug delivery achieves steady state. Although computed for phenylephrine, the concepts are generic and valid for any drug administered by IV infusion.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press