JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhang, L.
Right arrow Articles by Liu, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhang, L.
Right arrow Articles by Liu, J.
Related Collections
Right arrow Cardiovascular
Right arrow Surgery
Right arrow Technology

Anesth Analg 2007;105:700-703
© 2007 International Anesthesia Research Society
doi: 10.1213/01.ane.0000278135.85206.4e


TECHNOLOGY, COMPUTING, AND SIMULATION

Control of Blood Loss During Sacral Surgery by Aortic Balloon Occlusion

Lan Zhang, MM*, Quan Gong, MM{dagger}, Hong Xiao, MM*, Chongqi Tu, MM{dagger}, and Jin Liu, MD*

From the Departments of *Anesthesiology and {dagger}Orthopedics, West China Hospital, Sichuan University, Sichuan, People's Republic of China.

Address correspondence to Quan Gong, MM, Department of Orthopedics, West China Hospital, Sichuan University, No. 37, Guo-xue-xiang, Chengdu, Sichuan 610041, People's Republic of China. Address e-mail to quan_gong{at}163.com.

Radical sacral surgery can be associated with life-threatening blood loss. Effective and safe methods for controlling this blood loss remain elusive. We here report the use of an inflatable sizing balloon to intermittently occlude the distal abdominal aorta and control blood loss during sacral tumor resections. The balloon catheter was introduced into the abdominal aorta via the femoral artery. Pulse oxygen saturation signals from bilateral toes and ultrasonography were used to guide and confirm the location of the balloon in the abdominal aorta and distal to the renal arteries. The balloon was deflated for 10 min after each 60 min occlusion period. In five patients undergoing sacral tumor resection, the estimated blood loss when using balloon occlusion was <300 mL, and surgical duration was <2 h. No significant change in kidney, pelvic organ, and lower extremity function was found after the surgeries. Percutaneous aortic balloon occlusion can provide safe and effective control of blood loss during sacrococcygeal tumor resection.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2007 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press