JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 2007; 105:933-939
© 2007 International Anesthesia Research Society
doi: 10.1213/01.ane.0000278868.23814.3b
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tanaka, K. A.
Right arrow Articles by Levy, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tanaka, K. A.
Right arrow Articles by Levy, J. H.


CARDIOVASCULAR ANESTHESIOLOGY

Thrombin Generation Assay and Viscoelastic Coagulation Monitors Demonstrate Differences in the Mode of Thrombin Inhibition Between Unfractionated Heparin and Bivalirudin

Kenichi A. Tanaka, MD, MSc, Fania Szlam, MMSc, He Ying Sun, PhD, Taro Taketomi, MD, and Jerrold H. Levy, MD

From the Department of Anesthesiology, Emory University School of Medicine, Atlanta, Georgia.

Address correspondence and reprint requests to Kenichi A. Tanaka, MD, MSc, Emory University Hospital, 1364 Clifton Road, NE, Atlanta, GA. Address e-mail to kenichi.tanaka{at}emoryhealthcare.org.

Abstract

BACKGROUND: Coagulation tests, such as activated partial thromboplastin time and activated clotting time, are used to monitor the effects of unfractionated heparin and the direct thrombin inhibitor, bivalirudin. These tests reflect only the initial phase of blood clotting, when <5% of thrombin has been formed. In this study, we sought to determine if similar increases in activated partial thromboplastin time or activated clotting time due to heparin or bivalirudin would reflect the same degree of inhibition of thrombin formation.

METHODS: Thrombin formation was evaluated in platelet-poor plasma activated in the presence of heparin (0–5 U/mL) or bivalirudin (0–30 µg/mL) using a thrombin generation assay (ThrombinoscopeTM). Prothrombin activation was measured by prothrombin fragment 1.2 (F1.2) formation. Thrombus formation was further evaluated in kaolin-activated whole blood samples containing heparin (1.5 or 2.5 U/mL) or bivalirudin (12.5 or 25 µg/mL) using SonoclotTM and thromboelastography.

RESULTS: Based on the Thrombinoscope results, increasing concentrations of bivalirudin and heparin progressively delayed the onset of thrombin formation, but only heparin dose-dependently decreased the amount of thrombin generated. Heparin and bivalirudin delayed the onset of F1.2 formation, but there was no difference in peak F1.2 levels between bivalirudin and non-anticoagulated samples (206 ± 28.2 vs 182 ± 23.9 nmol/L, P = 0.09). In heparinized samples, F1.2 levels were significantly lower (75.7 ± 29.8 nmol/L, P < 0.05) than controls. Heparin and bivalirudin prolonged the onset of clotting on viscoelastic monitors, but only heparin decreased the rate of thrombus formation.

CONCLUSION: Thrombus formation kinetics differs between heparin and bivalirudin despite similar prolongation of clotting test values.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
D. Dirkmann, A. A. Hanke, K. Gorlinger, and J. Peters
Hypothermia and Acidosis Synergistically Impair Coagulation in Human Whole Blood
Anesth. Analg., June 1, 2008; 106(6): 1627 - 1632.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. T. Ganter and C. K. Hofer
Coagulation Monitoring: Current Techniques and Clinical Use of Viscoelastic Point-of-Care Coagulation Devices
Anesth. Analg., May 1, 2008; 106(5): 1366 - 1375.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press