JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 2007; 105:1629-1638
© 2007 International Anesthesia Research Society
doi: 10.1213/01.ane.0000287269.06170.0f
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by De Smet, T.
Right arrow Articles by Shafer, S. L.
Right arrow Search for Related Content
PubMed
Right arrow Articles by De Smet, T.
Right arrow Articles by Shafer, S. L.
Related Collections
Right arrow Drug Delivery
Right arrow Clinical Pharmacology
Right arrow Technology
Right arrow Pharmacology


ANESTHETIC PHARMACOLOGY

Estimation of Optimal Modeling Weights for a Bayesian-Based Closed-Loop System for Propofol Administration Using the Bispectral Index as a Controlled Variable: A Simulation Study

Tom De Smet, MSc*, Michel M. R. F. Struys, MD, PhD{dagger}{ddagger}, Scott Greenwald, PhD§, Eric P. Mortier, MD, DSc{dagger}, and Steven L. Shafer, PhD||¶

From *Demed Engineering, Temse, Belgium; {dagger}Department of Anesthesia, Ghent University Hospital, Gent, Belgium; {ddagger}Heymans Institute of Pharmacology, Ghent University, Gent, Belgium; §Aspect Medical Systems, Inc., Newton, Massachusetts; ||Stanford University School of Medicine, Stanford, California; and ¶University of California at San Francisco, San Francisco, California.

Address correspondence and reprint requests to Michel M.R.F Struys, Department of Anesthesia, Ghent University Hospital, Gent, Belgium. Address e-mail to michel.struys{at}UGent.be.

BACKGROUND: Implementing Bayesian methods in a model-based closed-loop system requires the integration of a standard response model with a patient-specific response model. This process makes use of specific modeling weights, called Bayesian variances, which determine how the specific model can deviate from the standard model. In this study we applied simulations to select the Bayesian variances yielding the optimal controller for a Bayesian-based closed-loop system for propofol administration using the Bispectral Index (BIS) as a controlled variable.

METHODS: The relevant Bayesian variances determining the modeling process were identified. Each set of such Bayesian variances represents a potential controller. The set, which will result in optimal control, was estimated using calculations on a simulated population.

We selected 625 candidate sets. Similar to our previous closed-loop performance study, we applied a simulation protocol to evaluate controller performance. Our population consisted of 416 virtual patients, generated using population characteristics from previous work. A BIS offset trajectory similar to a surgical case was used.

RESULTS: We were able to develop, describe, and optimize the parameter setting for a patient-individualized model-based closed-loop controller using Bayesian optimization. Selection of the optimal set yields a controller performing with the following median absolute prediction errors at BIS targets 30, 50, and 70: 12.9 ± 2.87, 7.59 ± 0.74, and 5.76 ± 1.03 respectively.

CONCLUSIONS: We believe this system can be introduced safely into clinical testing for both induction and maintenance of anesthesia under direct observation of an anesthesiologist.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
T. D. Smet, M. M. R. F. Struys, M. M. Neckebroek, K. V. den Hauwe, S. Bonte, and E. P. Mortier
The Accuracy and Clinical Feasibility of a New Bayesian-Based Closed-Loop Control System for Propofol Administration Using the Bispectral Index as a Controlled Variable
Anesth. Analg., October 1, 2008; 107(4): 1200 - 1210.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2007 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2007 by the International Anesthesia Research Society.