JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 2007; 105:1858-1860
© 2007 International Anesthesia Research Society
doi: 10.1213/01.ane.0000286814.79988.0a
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Klein, S. M.
Right arrow Articles by Smith, S. W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Klein, S. M.
Right arrow Articles by Smith, S. W.
Related Collections
Right arrow Regional Anesthesia
Right arrow Technology


ANALGESIA

Piezoelectric Vibrating Needle and Catheter for Enhancing Ultrasound-Guided Peripheral Nerve Blocks

Stephen M. Klein, MD*, Matthew P. Fronheiser, BS{dagger}, John Reach, MD{ddagger}, Karen C. Nielsen, MD*, and Stephen W. Smith, PhD{dagger}

From the Departments of *Anesthesiology and {dagger}Biomedical Engineering; {ddagger}Division of Orthopedics, Department of Surgery, Duke University Medical Center, Durham, North Carolina.

Address correspondence to Stephen M. Klein, MD, Department of Anesthesiology, Box 3094, Duke University Medical Center, Durham, NC 27710. Address e-mail to klein006{at}mc.duke.edu.

Abstract

Ultrasound imaging has been used for performing single-injection peripheral nerve blocks and continuous catheters. One limitation with current technology is the inability to confirm the location of the needle or catheter tip. We describe a new needle and catheter design that permits distal tip visualization using color flow Doppler. An 18-gauge 100-mm insulated Tuohy needle and a 20-gauge 50-mm polyamide catheter (open tip) with a Teflon-coated steel stylet (B. Braun, Bethlehem, PA) were customized by adhering in place two piezoelectric actuators. These created 1–8 kHz vibrations when coupled to a function generator (FG502, Tektronix, Richardson, TX) and a 100 W audio amplifier (R3000, KLH, Sun Valley, CA). Mimicking a lateral popliteal fossa block, the needle and catheter were inserted into the leg of an unembalmed cadaver. When activated, the tip of each was highlighted in color when scanned in the short axis using the color Doppler mode of a two-dimensional ultrasound and a 12 MHz L38 probe (MicroMaxx, Sonosite, Bothell, WA). Vibration technology may be a useful adjunct while performing ultrasound-guided regional anesthesia. Further study evaluating its usefulness and safety in live tissue is warranted.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2007 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2007 by the International Anesthesia Research Society.