JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 2008; 107:1646-1651
© 2008 International Anesthesia Research Society
doi: 10.1213/ane.0b013e318184ec14
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cappiello, E.
Right arrow Articles by Tsen, L. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cappiello, E.
Right arrow Articles by Tsen, L. C.
Related Collections
Right arrow Obstetrics
Right arrow Anesthetic Techniques
Right arrow Regional Anesthesia


OBSTETRIC ANESTHESIOLOGY

A Randomized Trial of Dural Puncture Epidural Technique Compared with the Standard Epidural Technique for Labor Analgesia

Eric Cappiello, MD, Nollag O'Rourke, FFARCSI, Scott Segal, MD, and Lawrence C. Tsen, MD

From the Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.

Address correspondence and reprint requests to Lawrence C. Tsen, MD, Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, 75, Francis St., CWN-L1 Harvard Medical School, Boston, MA 02115. Address e-mail to ltsen{at}zeus.bwh.harvard.edu.

Abstract

BACKGROUND: We designed this prospective, double-blind, randomized study to examine whether a dural puncture without intrathecal drug administration immediately before epidural drug administration would improve labor analgesia when compared to a traditional epidural technique without prior dural puncture.

METHODS: Eighty nulliparous parturients with cervical dilation less than 5 cm were randomly assigned to receive a standardized epidural technique, with or without a single dural puncture with a 25-gauge (G) Whitacre spinal needle. After successful placement of the needle(s) and the epidural catheter, 12 mL of bupivacaine 2.5 mg/mL was administered through the epidural catheter and a patient-controlled epidural infusion of bupivacaine 1.25 mg/mL + fentanyl 2 µg/mL was initiated. The presence of sacral analgesia (S1) and pain scores were compared between groups.

RESULTS: In demographically similar groups, parturients with prior dural puncture had more frequent blockade of the S1 dermatome (absolute risk difference [95% confidence interval] 22% [6–39]), more frequent visual analog scale scores <10/100 at 20 min (absolute risk difference 20% [1–38]), and reduced one-sided analgesia (absolute risk difference [95% CI] 17% [2–330]). The highest median sensory level (T10) was no different between groups.

CONCLUSIONS: Dural puncture with a 25-G spinal needle immediately before the initiation of epidural analgesia improves the sacral spread, onset, and bilateral pain relief produced by analgesic concentrations of bupivacaine with fentanyl in laboring nulliparous patients.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2008 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2008 by the International Anesthesia Research Society.