Anesth Analg 2009; 108:345-350
© 2009 International Anesthesia Research Society
doi: 10.1213/ane.0b013e31818c7da5
ANALGESIA
The Effects of Local Anesthetic Concentration and Dose on Continuous Infraclavicular Nerve Blocks: A Multicenter, Randomized, Observer-Masked, Controlled Study
Brian M. Ilfeld, MD, MS*,
Linda T. Le, MD ,
Joanne Ramjohn, MD ,
Vanessa J. Loland, MD*,
Anupama N. Wadhwa, MD ,
J. C. Gerancher, MD ,
Elizabeth M. Renehan, MSc, MD||,
Daniel I. Sessler, MD¶,
Jonathan J. Shuster, PhD#**,
Douglas W. Theriaque, MS**,
Rosalita C. Maldonado, BS*,
Edward R. Mariano, MD* For the PAINfRETM Investigators,
Section Editor Terese T. Horlocker
From the *Department of Anesthesiology, University of California San Diego, San Diego, California; Department of Anesthesiology, University of Florida, Gainesville, Florida; Department of Anesthesiology, University of Louisville, Louisville, Kentucky; Department of Anesthesiology, Wake Forest Medical Center, Winston-Salem, North Carolina; ||Department of Anesthesiology, University of Ottawa, Ottawa, Ontario, Canada; ¶Department of Outcomes Research, Cleveland Clinic, Cleveland, Ohio; #Department of Epidemiology and Health Policy Research, University of Florida, Gainesville, Florida; and **General Clinical Research Center, University of Florida, Gainesville, Florida.
Address correspondence to Brian M. Ilfeld, MD, MS, Department of Anesthesiology, UCSD Center for Pain Medicine, 9300 Campus Point Dr., MC 7651, La Jolla, CA 92037-7651. Address e-mail to bilfeld{at}ucsd.edu or www.or.org.
Abstract
BACKGROUND: It remains unclear whether local anesthetic concentration or total drug dose is the primary determinant of continuous peripheral nerve block effects. The only previous investigation, involving continuous popliteal-sciatic nerve blocks, specifically addressing this issue reported that insensate limbs were far more common with higher volumes of relatively dilute ropivacaine compared with lower volumes of relatively concentrated ropivacaine. However, it remains unknown if this relationship is specific to the sciatic nerve in the popliteal fossa or whether it varies depending on anatomic location. We therefore tested the null hypothesis that providing ropivacaine at different concentrations and rates, but at an equal total basal dose, produces comparable effects when used in a continuous infraclavicular brachial plexus block.
METHODS: Preoperatively, an infraclavicular catheter was inserted using the coracoid approach in patients undergoing moderately painful orthopedic surgery distal to the elbow. Patients were randomly assigned to receive a postoperative perineural ropivacaine infusion of either 0.2% (basal 8 mL/h, bolus 4 mL) or 0.4% (basal 4 mL/h, bolus 2 mL) through the second postoperative day. Both groups, therefore, received 16 mg of ropivacaine each hour with a possible addition of 8 mg every 30 min via a patient-controlled bolus dose. Our primary end point was the incidence of an insensate limb during the 24-h period beginning the morning after surgery. Secondary end points included analgesia and patient satisfaction.
RESULTS: Patients given 0.4% ropivacaine (n = 27) experienced an insensate limb, a mean (sd) of 1.8 (1.6) times, compared with 0.6 (0.9) times for subjects receiving 0.2% ropivacaine (n = 23; estimated difference = 1.2 episodes, 95% confidence interval, 0.5–1.9 episodes; P = 0.001). Satisfaction with postoperative analgesia (scale 0–10, 10 = highest) was scored a median (25th–75th percentiles) of 10.0 (8.0–10.0) in Group 0.2% and 7.0 (5.3–8.9) in Group 0.4% (P = 0.018). Analgesia was similar in each group.
CONCLUSIONS: For continuous infraclavicular nerve blocks, local anesthetic concentration and volume influence perineural infusion effects in addition to the total mass of local anesthetic administered. Insensate limbs were far more common with smaller volumes of relatively concentrated ropivacaine. This is the opposite of the relationship previously reported for continuous popliteal-sciatic nerve blocks. The interaction between local anesthetic concentration and volume is thus complex and varies among catheter locations.
This article has been cited by other articles:

|
 |

|
 |
 
E. R. Mariano, V. J. Loland, N. S. Sandhu, R. H. Bellars, M. L. Bishop, R. Afra, S. T. Ball, R. S. Meyer, R. C. Maldonado, and B. M. Ilfeld
Ultrasound Guidance Versus Electrical Stimulation for Femoral Perineural Catheter Insertion
J. Ultrasound Med.,
November 1, 2009;
28(11):
1453 - 1460.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. M. Ilfeld, E. R. Mariano, V. J. Loland, and D. I. Sessler
In Response:
Anesth. Analg.,
October 1, 2009;
109(4):
1348 - 1349.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. J. Chin, A. Perlas, V. Chan, and R. Brull
Continuous Infraclavicular Plexus Blockade
Anesth. Analg.,
October 1, 2009;
109(4):
1347 - 1348.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. R. Mariano, V. J. Loland, R. H. Bellars, N. S. Sandhu, M. L. Bishop, R. A. Abrams, M. J. Meunier, R. C. Maldonado, E. J. Ferguson, and B. M. Ilfeld
Ultrasound Guidance Versus Electrical Stimulation for Infraclavicular Brachial Plexus Perineural Catheter Insertion
J. Ultrasound Med.,
September 1, 2009;
28(9):
1211 - 1218.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|