JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 2009; 108:1546-1552
© 2009 International Anesthesia Research Society
doi: 10.1213/ane.0b013e31819bdfbb
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Görges, M.
Right arrow Articles by Westenskow, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Görges, M.
Right arrow Articles by Westenskow, D. R.
Related Collections
Right arrow Trauma
Right arrow Equipment
Right arrow Patient Safety
Right arrow Technology


TECHNOLOGY, COMPUTING, AND SIMULATION

Improving Alarm Performance in the Medical Intensive Care Unit Using Delays and Clinical Context

Matthias Görges, MS*, Boaz A. Markewitz, MD{dagger}, and Dwayne R. Westenskow, PhD*

From the *Department of Anesthesiology, University of Utah; and {dagger}Division of Respiratory, Critical Care, and Occupational Pulmonary Medicine, Department of Internal Medicine, University of Utah, Salt Lake City, Utah.

Address correspondence and reprint requests to Matthias Görges, MS, Department of Anesthesiology, University of Utah, 30 N. 1900 E., SOM 3C444, Salt Lake City, UT 84132. Address e-mail to matthias{at}abl.med.utah.edu.

INTRODUCTION: In an intensive care unit, alarms are used to call attention to a patient, to alert a change in the patient's physiology, or to warn of a failure in a medical device; however, up to 94% of the alarms are false. Our purpose in this study was to identify a means of reducing the number of false alarms.

METHODS: An observer recorded time-stamped information of alarms and the presence of health care team members in the patient room; each alarm response was classified as effective (action taken within 5 min), ineffective (no response to the alarm), and ignored (alarm consciously ignored or actively silenced).

RESULTS: During the 200-h study period, 1271 separate entries by an individual to the room being observed were recorded, 1214 alarms occurred and 2344 tasks were performed. On average, alarms occurred 6.07 times per hour and were active for 3.28 min per hour; 23% were effective, 36% were ineffective, and 41% were ignored. The median alarm duration was 17 s. A 14-s delay before alarm presentation would remove 50% of the ignored and ineffective alarms, and a 19-s delay would remove 67%. Suctioning, washing, repositioning, and oral care caused 152 ignored or ineffective ventilator alarms.

DISCUSSION: Introducing a 19-s alarm delay and automatically detecting suctioning, repositioning, oral care, and washing could reduce the number of ineffective and ignored alarms from 934 to 274. More reliable alarms could elicit more timely response, reduce workload, reduce noise pollution, and potentially improve patient safety.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
M. Imhoff and R. Fried
The Crying Wolf: Still Crying?
Anesth. Analg., May 1, 2009; 108(5): 1382 - 1383.
[Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2009 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2009 by the International Anesthesia Research Society.