JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 2009; 108:1592-1598
© 2009 International Anesthesia Research Society
doi: 10.1213/ane.0b013e31819e016d
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Teoh, W. H. L.
Right arrow Articles by Sia, A. T. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Teoh, W. H. L.
Right arrow Articles by Sia, A. T. H.
Related Collections
Right arrow Obstetrics
Right arrow Physiology


OBSTETRIC ANESTHESIOLOGY

Colloid Preload Versus Coload for Spinal Anesthesia for Cesarean Delivery: The Effects on Maternal Cardiac Output

Wendy H. L. Teoh, FANZCA, and Alex T. H. Sia, M.MED

From the Department of Women’s Anesthesia, KK Women’s and Children’s Hospital, Singapore.

Address correspondence and reprint requests to Dr. Wendy H.L. Teoh, Department of Women’s Anesthesia, KK Women’s and Children’s Hospital, 100 Bukit Timah Rd., Singapore 229899. Address e-mail to teohwendy{at}yahoo.com.

Abstract

BACKGROUND: Spinal anesthesia for cesarean delivery may cause severe maternal hypotension, and a decrease in cardiac output (CO) and blood flow to the placenta. Fluid preloading with crystalloid is ineffective due to rapid redistribution. A "coload" given at the time of cerebrospinal fluid identification may be more effective. Our null hypothesis was that there would be no difference between the effect of a colloid preload (15 mL/kg hydroxyethyl starch (HES) 130/0.4 [Voluven® 6%]) and an identical coload on maternal CO and the incidence of hypotension after spinal anesthesia for cesarean delivery. Secondary outcomes studied were neonatal acid- base status and predelivery vasopressor requirements.

METHODS: Forty ASA PS I and II women scheduled for elective cesarean delivery were recruited. Patients were randomized to Group P (preload of 15 mL/kg HES) or Group C (coload, given when cerebrospinal fluid identified). Heart rate, arterial blood pressure, stroke volume and CO measurements were recorded at baseline, every minute for 10 min, and every 2.5 min interval for 10 min with the USCOMTM ultrasonic CO monitor. Spinal anesthesia was performed at the L3/4 interspace in the right lateral position. Arterial blood pressure was maintained at 90%–100% of baseline values using IV phenylephrine boluses.

RESULTS: Demographic, anesthetic, and surgical characteristics were similar. There were no between-group differences in baseline systolic blood pressure, heart rate, and colloid volume. CO and stroke volume were significantly increased in Group P (P = 0.01) in the 5 min after spinal anesthesia. This increase in CO was not sustained at 10 min. There were no significant between-group differences in the incidence of hypotension, absolute arterial blood pressure values (P = 0.73), predelivery median (range) phenylephrine requirements (300[0–1000] in Group P versus 150 [0–850]µg in Group C, P = 0.24), or neonatal outcome as measured by Apgar scores and umbilical arterial and venous blood gas values.

CONCLUSION: Intravascular volume expansion with 15 mL/kg HES 130/0.4 given as a preload, but not coload, significantly increased maternal CO for the first 5 min after spinal anesthesia for cesarean delivery, however, maternal and neonatal outcomes were not different.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2009 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press