Anesth Analg 2009; 109:441-446
© 2009 International Anesthesia Research Society
doi: 10.1213/ane.0b013e3181a8d81f
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Reekers, M.
Right arrow Articles by Vuyk, J.
PubMed
Right arrow Articles by Reekers, M.
Right arrow Articles by Vuyk, J.
Related Collections
Right arrow Physiology
Right arrow Technology


TECHNOLOGY, COMPUTING, AND SIMULATION

Cardiovascular Monitoring by Pulse Dye Densitometry or Arterial Indocyanine Green Dilution

Marije Reekers, MD, Mischa J. G. Simon, MD, PhD, Fred Boer, MD, PhD, René A. G. Mooren, BSc, Jack W. van Kleef, MD, PhD, Albert Dahan, MD, PhD, and Jaap Vuyk, MD, PhD

From the Department of Anesthesiology, Leiden University Medical Centre, Leiden, The Netherlands.

Address correspondence to Marije Reekers, MD, Department of Anesthesiology, Leiden University Medical Centre, PO Box 9600, 2300 RC, Leiden, The Netherlands. Address e-mail to m.reekers{at}lumc.nl.

BACKGROUND: Noninvasive cardiac output (CO) monitoring is possible by indocyanine green (ICG) dilution measured by pulse dye densitometry (PDD). To validate the precision of this method, we compared hemodynamic variables derived from PDD (DDG-2001, Nihon Kohden, Japan) with those derived from simultaneously taken arterial blood ICG concentrations.

METHODS: In 20 patients (6 M/14 F), ASA I or II, 36 sessions were performed (n = 24 with the PDD-finger probe, n = 10 with the PDD-nose probe). After IV administration of 10 mg ICG, 34 arterial blood samples were taken during each session, with 20 samples taken during the first 2 min. CO, central blood volume (CBV), and total blood volume (TBV) were calculated independently from ICG and PDD and the results compared between methods using Bland-Altman analysis. The results are reported as mean difference (bias) and limits of agreement (LOA = ± 2 sd).

RESULTS: PDD using the finger probe underestimated CO (LOA) by 5% (–56% and 47%); overestimated CBV by 21% (–54% and 96%) and underestimated TBV by –15% (–38% and 8%). PDD using the nose probe overestimated CO (LOA) by 30% (–67% and 127%); CBV by 48% (–98% and 193%) and underestimated TBV by –10% (–47% and 27%).

CONCLUSION: Despite the permissible bias, the wide LOA of the PDD-derived hemodynamic variables CO and CBV, compared with those simultaneously obtained by invasive arterial ICG measurements, suggest that PDD is unsuitable for evaluation of cardiovascular variables in the individual patient. Hence, the reliability and clinical use of this method seem limited.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2009 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press