JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1981; 60:579-583
© 1981 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McCammon, R. L.
Right arrow Articles by Stoelting, R. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McCammon, R. L.
Right arrow Articles by Stoelting, R. K.

Effect of Propranolol on Circulatory Responses to Induction of Diazepam-Nitrous Oxide Anesthesia and to Endotracheal Intubation

Richard L. McCammon, MD*, John C. Hilgenberg, MD*, and Robert K. Stoelting, MD{dagger}

*Assistant Professor. {dagger}Professor and Chairman. Received from the Department of Anesthesia, Indiana University School of Medicine, 1100 West Michigan Street, Indianapolis, Indiana 46223.

Abstract

The present study evaluated the hemodynamic effects produced by the intravenous infusion of diazepam (0.5 mg/kg over 10 minutes) and the simultaneous inhalation of 50% nitrous oxide in oxygen administered to 19 patients with coronary artery disease who were receiving chronic propranolol therapy (106 ± 67 mg/day). In addition, hemodynamic changes produced by direct laryngoscopy and intubation of the trachea were measured. Data during the induction of anesthesia were compared to measurements obtained in a previously reported group of similar patients anesthetized in the same manner but not receiving propranolol. In the present study, as in previously observed patients not receiving propranolol, induction of anesthesia with diazepam-nitrous oxide did not result in any significant change from awake measurements with respect to heart rate (HR), mean arterial pressure (MAP), or rate-pressure product (RPP). Cardiovascular responses were similar in patients with awake resting heart rates greater than 70 beats per minute (nine patients) and less than 70 beats per minute (10 patients). This suggests that propranolol does not alter the benign hemodynamic effects produced by this type of induction of anesthesia. Laryngoscopy and tracheal intubation significantly (p < 0.01) increased MAP at 1 minute and HR and RPP at 1 and 2 minutes after the start of laryngoscopy. These changes were transient, returning to control values within 3 minutes after intubation. Patients with awake resting HR less than 70 beats per minute had greater increases in HR and RPP at 1 minute than did patients with resting HR greater than 70 beats per minute (p < 0.05). This suggests that propranolol even in doses adequate to produce significant slowing of HR in awake Patients does not ensure protection against increases in HR and MAP associated with laryngoscopy and intubation of the trachea.

Key Words: SYMPATHETIC NERVOUS SYSTEM: sympathetic agents, propranolol • ANESTHESIA: cardiovascular • SURGERY: cardiovascular.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1981 by the International Anesthesia Research Society.