JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1985; 64:688-692
© 1985 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Drummond, J. C.
Right arrow Articles by Scheller, M. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Drummond, J. C.
Right arrow Articles by Scheller, M. S.

A Comparison of the Sensitivity of Pulmonary Artery Pressure, End-Tidal Carbon Dioxide, and End-Tidal Nitrogen in the Detection of Venous Air Embolism in the Dog

John C. Drummond, MD, FRCP(C), Richard J. Prutow, PhD, MD, and Mark S. Scheller, MD

Received from the Neuroanesthesia Research Laboratory, Department of Anesthesiology, University of California at San Diego, La Jolla, California and the Department of Anesthesiology, Veterans' Administration Medical Center, San Diego, California.

Abstract

The authors sought to define the relative sensitivities of endtidal carbon dioxide analysis (ETco2), end-tidal nitrogen analysis (ETN2), and pulmonary artery pressure (PAP) monitoring in the detection of venous air embolism (VAE). Serial injections of air (0.25, 0.5, 0.75, 1.0, arid 1.5 ml/kg) were performed in six mongrel dogs. The frequency with which positive responses (PAP increase > 2 mm Hg; ETCO2 decrease > 0.2%; ETN2 increase > 0.04%) were observed following VAE was not different for the three methods. The response time (time to maximum change following VAE) was significantly more rapid for PAP and ETN2 than for ETCO2; although the range for the three methods was narrow, e.g., for 1.5 ml/kg—PAP, 0.92 ± 0.7 (SD) min; ETN2, 1.20 ± 0.5 min; ETCO2, 1.85 ± 0.7 min. The time from injection of air to return to baseline levels was significantly more rapid for ETN2 than for ETCO2 which was in turn significantly significantly faster than PAP, e.g., for 1.5 ml/kg—ETN2, 8.0 ± 4.3 min; ETCO2, 19.4 ± 6.0 min; PAP, 23.8 ± 6.1 min. The results indicate that, where the capacity to identify increases in expired nitrogen on the order of 0.04% can be achieved, ETN2 monitoring mill identify VAE events with a sensitivity similar to that of PAP and ETCO2. However, the difficulties inherent in achieving this level of nitrogen detection sensitivity probably represent a current major limitation in the application of this method. Furthermore, the data indicate that, after VAE, ETN2 will return to preinjection levels although PAP and ETCO2 remain abnormal. This observation suggests that ETN2 may not be a reliable indicator of recovery from the physiologic impact of VAE, and may therefore not be the optimum method to base decisions regarding resumption of the head-up posture and continuation of surgery during procedures in which VAE bas occurred.

Key Words: EMBOLISM—air • MONITORING—endtidal gases




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. T. Schafer, J. Lindemann, P. Brendt, G. Kaiser, and J. Peters
Intracardiac Transvenous Echocardiography Is Superior to Both Precordial Doppler and Transesophageal Echocardiography Techniques for Detecting Venous Air Embolism and Catheter-Guided Air Aspiration
Anesth. Analg., January 1, 2008; 106(1): 45 - 54.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
H. A. Zar and W. W. Wu
The Inability to Detect Expired Carbon Dioxide After Endotracheal Intubation as a Result of One-Way Valve Obstruction of the Endotracheal Tube
Anesth. Analg., October 1, 2001; 93(4): 971 - 972.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
R. T. Hegde and R. N. Avatgere
Air embolism during anaesthesia for shoulder arthroscopy
Br. J. Anaesth., December 1, 2000; 85(6): 926 - 927.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press