JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1986; 65:1161-1169
© 1986 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Breen, P. H.
Right arrow Articles by Craig, D. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Breen, P. H.
Right arrow Articles by Craig, D. B.

Constant Flow Ventilation in Anesthetized Patients

Efficacy and Safety

Peter H. Breen, MD, J. Iasha Sznajder, MD, Paulette Morrison, RRT, Don Hatch, Larry D. H. Wood, MD, and Douglas B. Craig, MD

Department of Anesthesia, University of Manitoba, Winnipeg, MB, and the Section of Pulmonary and Critical Care Medicine and the Department of Anesthesia and Critical Care, University of Chicago, Chicago, Illinois.

Abstract

Constant flow ventilation (CFV) maintains normal gas exchange in apneic dogs and has potential clinical application during thoracic surgery or pulmonary edema. We compared CFV and intermittent positive pressure ventilation (IPPV) in five healthy, anesthetized, (fentanyl, diazepam, and nitrous oxide) and paralyzed patients undergoing nonthoracic operations. Constant flow ventilation was delivered at a total flow of 0.9–1.6 L·kg 1·min–1 (nitrous oxide-oxygen of 1:1) into two tubes of 2.5–3.5 mm inner diameter attached to each side of an 8–9 mm inner diameter orotracheal tube (OTT). Under brochoscopic guidance, the CFV-OTT was advanced to position each ventilating tube at a mainstem bronchial orifice. Gas exhausted through the OTT lumen. If intrathoracic pressure exceeded a preset limit, a solenoid valve automatically interrupted gas flow to the patient to prevent barotraumas. Compared to IPPV, during CFV for up to 30 min average PaCO2 increased to 69.2 ± 14.5 from 35.9 ± 2.9 mil Hg, reflecting a calculated alveolar ventilation (VA) of 46 ± 22% of the eucapnic level. We suggest that a technique combining CFV at lower flow rates with IPPV may prom clinically useful by allowing decreased tidal volume and inspiratory pressure while maintaining normal VA.

Key Words: VENTILATION—constant flow







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1986 by the International Anesthesia Research Society.