JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1986; 65:777-780
© 1986 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Petring, O. U.
Right arrow Articles by Lomholt, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Petring, O. U.
Right arrow Articles by Lomholt, N.

Prevention of Silent Aspiration Due to Leaks around Cuffs of Endotracheal Tubes

Oscar U. Petring, MD, Benny Adelhøj, MD, Birgitte N. Jensen, MD, Niels O. Pedersen, MD, and Niels Lomholt, MD

Department of Anaesthesia, Kommunehospitalet, and the Department of Pharmacology, University of Copenhagen, Copenhagen, Denmark.

Abstract

Significant aspiration may occur around correctly inflated high volume, low pressure endotracheal tube cuffs. The prevention of silent aspiration due to leaks around cuffs of endotracheal tubes was investigated during general anesthesia for hip replacement in 47 patients. The patients were randomly assigned to one of three groups, in which one of three endotracheal tubes of different designs were used for intubation. The following three tubes were used: the red rubber Rüsch tube with low residual volume cuff, inflated to minimum occluding volume; the Mallinckrodt Hi-Lo tube with high residual volume cuff; the NL tube with high residual volume cuff and automatic cuff pressure regulation. The cuffs on the Mallinckrodt and the NL tubes were inflated to 29–31 cm H2O. One hour before termination of the surgical procedure, 1 ml methylene blue dye was injected into the trachea just above the cuff through a thin channel built into the tubes. At termination of the operation, the trachea below the cuff was inspected with a fiberoptic bronchoscope. Aspiration was found in 12.5% with the Rüsch tube, in 31.2% with the Mallinckrodt tube, and in 0% with the NL tube. Our resuts show that silent aspiration is still a problem with standard endotracheal tubes, but that it may be minimized by use of appropiate tubes, cuffs, and control of cuff inflation.

Key Words: EQUIPMENT, TUBES—tracheal • INTUBATION—tracheal • LUNG—aspiration




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
L. Lorente, M. Lecuona, A. Jimenez, M. L. Mora, and A. Sierra
Influence of an Endotracheal Tube with Polyurethane Cuff and Subglottic Secretion Drainage on Pneumonia
Am. J. Respir. Crit. Care Med., December 1, 2007; 176(11): 1079 - 1083.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. Efrati, Y. Leonov, A. Oron, Y. Siman-Tov, M. Averbukh, A. Lavrushevich, and A. Golik
Optimization of Endotracheal Tube Cuff Filling by Continuous Upper Airway Carbon Dioxide Monitoring
Anesth. Analg., October 1, 2005; 101(4): 1081 - 1088.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
D. A. Mark
Protection from aspiration with the LMA-ProSealTM after vomiting: a case report: [La protection contre l'aspiration avec le ML-ProSealTM apres des vomissements : une etude de cas]
Can J Anesth, January 1, 2003; 50(1): 78 - 80.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R. Farre, M. Rotger, M. Ferrer, A. Torres, and D. Navajas
Automatic regulation of the cuff pressure in endotracheally-intubated patients
Eur. Respir. J., October 1, 2002; 20(4): 1010 - 1013.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
R. S. Morehead and S. J. Pinto
Ventilator-Associated Pneumonia
Arch Intern Med, July 10, 2000; 160(13): 1926 - 1936.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1986 by the International Anesthesia Research Society.