JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1990; 71:181-184
© 1990 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Watcha, M. F.
Right arrow Articles by Forestner, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Watcha, M. F.
Right arrow Articles by Forestner, J. E.

Effects of Halothane on Intraocular Pressure in Anesthetized Children

Mehernoor F. Watcha, MD, Fred C. Chu, MD, Julia L. Stevens, MD, and John E. Forestner, MD

Departments of Anesthesiology and Ophthalmology, Washington University School of Medicine, St. Louis, Missouri.

Abstract

Intraocular pressure (IOP) measurements in children are usually performed under nitrous oxide and halothane anesthesia. We studied the effects of both time and end-tidal halothane concentration on IOP in 80 children (mean age ± SD = 4.5 ± 2.9 yr), to determine the most optimal time to make such measurements in anesthetized children. In 30 children the end-tidal halothane and nitrous oxide concentrations were kept constant while IOP was measured at 1-min intervals after the induction of anesthesia. Intraocular pressure did not change with time. In another 50 children 10P was measured immediately after induction, after 10 min of steady-state end-tidal halothane concentrations of both 0.5% and 1.0% in 66% nitrous oxide, and immediately after tracheal intubation. Intraocular pressure did not differ significantly at either halothane concentration but increased after tracheal intubation. We conclude that in patients anesthetized with halothane and nitrous oxide, IOP after induction remains constant over time and is not affected by end-tidal halothane concentrations up to 1.0% but is affected by tracheal intubation. Thus, the optimal time to measure IOP in children receiving up to 1% halothane in 66% nitrous oxide is during the first 10 min after induction, but before tracheal intubation.

Key Words: ANESTHESIA, PEDIATRIC-intraocular pressure • EYE, INTRAOCULAR PRESSURE • ANESTHETICS, VOLATILE-halothane







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 1990 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1990 by the International Anesthesia Research Society.