the Department of Anesthesiology, Emory University School of Medicine, and the Department of Pathology and Laboratory Medicine, Emory University Hospital, Atlanta, Georgia.
Abstract
Contaminated breathing systems have been responsible for nosocomial upper respiratory tract and pulmonary infections in patients undergoing general anesthesia. The current infection control guidelines for anesthesia breathing circuits require single-patient use or high-level disinfection of breathing tubes, y-connector, and reservoir bag. An alternative infection control strategy has been suggested that incorporates placement of a microbial filter downstream from the y-connector between the circuit and the patient. This laboratory study assessed the capacity of the Pall HME Filter as a bidirectional barrier to transmission of bacteria between the y-connector of an anesthesia circle breathing system and a test lung. The investigators modified a sterile circle system to allow aerosolization of a suspension of 109 Micrococcus luteus over 5 h into the inspiratory limb proximal to the y-connector or downstream from the filter into the test lung. Cultures indicated that the Pall HME filter placed between the y-connector and the test lung completely prevented transmission of bacteria in both directions. The results of this study suggest that the Pall HME Filter could be used as an effective microbial barrier between the anesthesia circle breathing system and the patient as part of an alternative strategy for infection control.
Key Words: EQUIPMENT, ANESTHESIA CIRCUITS—filters. INFECTION, PREVENTION—anesthesia circuit filters.
This article has been cited by other articles:
![]() |
R. G. Masterton, A. Galloway, G. French, M. Street, J. Armstrong, E. Brown, J. Cleverley, P. Dilworth, C. Fry, A. D. Gascoigne, et al. Guidelines for the management of hospital-acquired pneumonia in the UK: Report of the Working Party on Hospital-Acquired Pneumonia of the British Society for Antimicrobial Chemotherapy J. Antimicrob. Chemother., July 1, 2008; 62(1): 5 - 34. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. G. Lawes Hidden hazards and dangers associated with the use of HME/filters in breathing circuits. Their effect on toxic metabolite production, pulse oximetry and airway resistance Br. J. Anaesth., August 1, 2003; 91(2): 249 - 264. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. R. Demers Bacterial/Viral Filtration : Let the Breather Beware! Chest, October 1, 2001; 120(4): 1377 - 1389. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. B. Langevin, K. H. Rand, and A. J. Layon The Potential for Dissemination of Mycobacterium tuberculosis Through the Anesthesia Breathing Circuit Chest, April 1, 1999; 115(4): 1107 - 1114. [Abstract] [Full Text] [PDF] |
||||
|