JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


Anesth Analg 1992; 75:495-498
© 1992 International Anesthesia Research Society
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'Leary, R. J.
Right arrow Articles by Benumof, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by O'Leary, R. J., Jr.
Right arrow Articles by Benumof, J. L.

Buccal Pulse Oximeter Is More Accurate Than Finger Pulse Oximeter in Measuring Oxygen Saturation

Richard J. O'Leary, Jr., BA, Mark Landon, MD, and Jonathan L. Benumof, MD

Department of Anesthesiology, University of California—San Diego, School of Medicine, San Diego, California

Abstract

Although there have been several anecdotal reports of the use of buccal pulse oximeter monitoring (Spo2) when digital Spo2 monitoring cannot be used, there have been no objective evaluations of the accuracy of buccal Spo2 monitoring. The purpose of this study was to systematically compare buccal Spo2 monitoring to both digital Spo2 and arterial 02 saturation monitoring (Sao2) in both generally anesthetized patients in the operating room (n = 31) and critically ill patients in the intensive care unit (n = 23). Buccal Spo2 probes were prepared by taping a malleable metal bar securely over the back of a Nellcor Oxisen-sor D-25 probe and bending the metal bar and buccal probe firmly around the corner of the patient's mouth. All buccal and finger Spo2 and Sao2 measurements were made simultaneously during hemodynamic stability. We found that buccal Spo2 was higher than finger Spo2 and agreed more closely with Sao2 for both patient groups (98.1% ± 2.6%, 96.8% ± 3.5%, 98.5% ± 2.5%, respectively [mean ± SD]). The operating room patients had higher buccal and finger Spo2 and Sao2 (99.3% ± 1.5%, 98.9% ± 1.4%, 99.5% ± 0.7%, respectively) than the intensive care unit patients (96.4% ± 2.9%, 94.1% ± 3.5%, 96.6% ± 3.5%, respectively). Although buccal Spo2 monitoring has several disadvantages (i.e., the probe requires preparation, can be more difficult to place, may be less readily accepted in awake patients, and is often mechanically dislodged during airway maneuvers), we conclude that buccal Spo2 monitoring is a more than adequate oximetry alternative when digital Spo2 monitoring is not an option (digits are unavailable or available digits are mechanically interfered with).




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
P. D. Mannheimer
The Light Tissue Interaction of Pulse Oximetry
Anesth. Analg., December 1, 2007; 105(6S_Suppl): S10 - S17.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
W. Wei, Z. Zhu, L. Liu, Y. Zuo, M. Gong, F. Xue, and J. Liu
A Pilot Study of Continuous Transtracheal Mixed Venous Oxygen Saturation Monitoring
Anesth. Analg., August 1, 2005; 101(2): 440 - 443.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Margreiter, C. Keller, and J. Brimacombe
The Feasibility of Transesophageal Echocardiograph-Guided Right and Left Ventricular Oximetry in Hemodynamically Stable Patients Undergoing Coronary Artery Bypass Grafting
Anesth. Analg., April 1, 2002; 94(4): 794 - 798.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Brimacombe, C. Keller, and J. Margreiter
A Pilot Study of Left Tracheal Pulse Oximetry
Anesth. Analg., October 1, 2000; 91(4): 1003 - 1006.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
C. Keller, J. Brimacombe, F. Agro, and J. Margreiter
A Pilot Study of Pharyngeal Pulse Oximetry with the Laryngeal Mask Airway: A Comparison with Finger Oximetry and Arterial Saturation Measurements in Healthy Anesthetized Patients
Anesth. Analg., February 1, 2000; 90(2): 440 - 440.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 1992 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 1992 by the International Anesthesia Research Society.