JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grenier, B.
Right arrow Articles by Maurette, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grenier, B.
Right arrow Articles by Maurette, P.
Anesth Analg 1999;88:43-48
© 1999 International Anesthesia Research Society


NEUROSURGICAL ANESTHESIA

Capnography Monitoring During Neurosurgery: Reliability in Relation to Various Intraoperative Positions

Bruno Grenier, MD*, Eric Verchère, MD*, Abdelghani Mesli, MD*, Marc Dubreuil, MD{dagger}, Daniel Siao, MD*, Monique Vandendriessche, MD*, Jacques Calès, MD*, and Pierre Maurette, MD*

Departments of *Anesthesiology 3 and {dagger}Anesthesiology 4, University Hospital, Bordeaux, France

Address correspondence and reprint requests to B. Grenier, DAR 3, Hôpital Pellegrin, 33076 Bordeaux Cedex, France. Address e-mail to bruno.grenier{at}chu-aquitaine.fr

In neurosurgery, estimation of PaCO2 from PETCO2 has been questioned. The aim of this study was to reevaluate the accuracy of PETCO2 in estimating PaCO2 during neurosurgical procedures lasting >3 h and to measure the effect of surgical positioning on arterial to end-tidal CO2 gradient (P[a-ET]CO2) over time. One hundred four neurosurgical patients classified into four groups (supine [SP], lateral [LT], prone [PR], sitting [ST]) were included in a prospective study. PaCO2, PETCO2, and P(a-ET)CO2 were measured after induction of anesthesia (T0), after positioning (T1), each following hour (T2, T3, T4), and at the end of the procedure after return to the SP position (T5). Data are expressed as the mean ± SD, and statistical analysis used linear regression, the Bland-Altman method, and analysis of variance. The mean durations of positioning and surgery were 4.1 ± 1 h and 3.7 ± 1.3 h, respectively. We performed 624 simultaneous measurements of PaCO2 (33 ± 5 mm Hg) and PETCO2 (27 ± 4 mm Hg), leading to a mean P(a-ET)CO2 of 6 ± 4 mm Hg. P(a-ET)CO2 of the LT group (7 ± 3 mm Hg) was larger (compared with the SP, PR, and ST groups) because of a lower PETCO2 (26 ± 4 mm Hg). Negative P(a-ET)CO2 (PETCO2 > PaCO2) occurred 22 times, only in the SP (n = 9) and ST groups (n = 13). Changes in opposite directions of PETCO2 and PaCO2 between two successive measurements were found in 26% of the cases. Correlation coefficients in the four groups (PaCO2 versus PETCO2) were not in good agreement (0.46 to 0.62; P < 0.001). The mean bias was between 5 and 7 mm Hg. The superior (13–15 mm Hg) and inferior (-5 to 0 mm Hg) limits of agreement were too large to expect PETCO2 to replace PaCO2. In conclusion, during neurosurgical procedures of >3 h, capnography should be performed with regular analysis of arterial blood gases for optimal ventilator adjustment.

Implications: This study, which aimed to reevaluate the ability of PETCO2 to estimate PaCO2 during neurosurgical procedures according to surgical position, indicates that PETCO2 cannot replace PaCO2 for the following reasons: scattering of individual values; occurrence of negative arterial to end-tidal CO2 gradient (P[a-ET]CO2; PaCO2 and PETCO2 variations in opposite directions; large changes in P(a-ET)CO2 between two samples; and instability of P(a-ET)CO2 over time.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
A. Kober, B. Schubert, P. Bertalanffy, L. Gorove, T. Puskas, B. Gustorff, A. Joldzo, and K. Hoerauf
Capnography in Non-Tracheally Intubated Emergency Patients as an Additional Tool in Pulse Oximetry for Prehospital Monitoring of Respiration
Anesth. Analg., January 1, 2004; 98(1): 206 - 210.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
J. Griffin, B. E. Terry, R. K. Burton, T. L. Ray, B. P. Keller, A. L. Landrum, J. O. Johnson, and J. D. Tobias
Comparison of end-tidal and transcutaneous measures of carbon dioxide during general anaesthesia in severely obese adults
Br. J. Anaesth., October 1, 2003; 91(4): 498 - 501.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Oshibuchi, S. Cho, T. Hara, S. Tomiyasu, T. Makita, and K. Sumikawa
A Comparative Evaluation of Transcutaneous and End-Tidal Measurements of CO2 in Thoracic Anesthesia
Anesth. Analg., September 1, 2003; 97(3): 776 - 779.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press