Anesth Analg 1999;89:1257
© 1999 International Anesthesia Research Society
OBSTETRIC ANESTHESIA
Comparison of 9 mg of Intrathecal Plain and Hyperbaric Bupivacaine Both with Fentanyl for Cesarean Delivery
P. Johanna Sarvela, MD, PhD,
Pekka M. Halonen, MD, and
Kari T. Korttila, MD, PhD, Professor in Anesthesia and Intensive Care
Anesthesia Research Group, Department of Obstetrics and Gynaecology, Helsinki University Central Hospital, Helsinki, Finland
Address correspondence and reprint requests to Johanna Sarvela, MD, PhD, Anesthesia Research Group, Department of Obstetrics and Gynaecology, Helsinki University Central Hospital, PO Box 140, FIN-00029 HYKS. Address e-mail to johanna.sarvela{at}huch.fi
We randomized 76 parturients to a double-blinded trial to receive spinal anesthesia with either hyperbaric or plain bupivacaine 9 mg with fentanyl 20 µg for elective cesarean delivery. A combined spinal-epidural technique was used. The onset and duration of anesthesia (absence of pinprick sensation), analgesia (absence of sharp sensation to pinprick), and absence of cold sensation and motor block were measured until recovery from the motor block. No major differences were seen in onset or duration of anesthesia between the groups. Motor block, however, vanished faster when hyperbaric bupivacaine was used (P < 0.05). The level of anesthesia (no pinprick sensation) required for painless operation was at dermatome T5. At this time, the absence of cold sensation ranged from dermatome T1 to C3. The median time for the anesthesia to reach dermatome T5 was 10 min. Cervical spread of pinprick anesthesia was noted in six patients, and five needed supplementary analgesics during surgery (not significant between the groups). Maternal satisfaction was good. Nine milligrams of either plain or hyperbaric bupivacaine with fentanyl intrathecally provided similar onset, depth, and duration of sensory anesthesia for cesarean delivery with good maternal satisfaction. Motor block developed and diminished faster with the hyperbaric solution.
Implications: Nine milligrams of either plain or hyperbaric bupivacaine with fentanyl intrathecally provided similar onset, depth, and duration of sensory anesthesia for cesarean delivery with good maternal satisfaction. Motor block developed and diminished faster with the hyperbaric solution.
This article has been cited by other articles:

|
 |

|
 |
 
M. Van de Velde, D. Van Schoubroeck, J. Jani, A. Teunkens, C. Missant, and J. Deprest
Combined spinal-epidural anesthesia for cesarean delivery: dose-dependent effects of hyperbaric bupivacaine on maternal hemodynamics.
Anesth. Analg.,
July 1, 2006;
103(1):
187 - 190.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. Lew, S.-W. Yeo, and E. Thomas
Combined Spinal-Epidural Anesthesia Using Epidural Volume Extension Leads to Faster Motor Recovery After Elective Cesarean Delivery: A Prospective, Randomized, Double-Blind Study
Anesth. Analg.,
March 1, 2004;
98(3):
810 - 814.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. C. S. Law, K. K. Lam, and M. G. Irwin
The Effect of Right Versus Left Lateral Decubitus Positions on Induction of Spinal Anesthesia for Cesarean Delivery
Anesth. Analg.,
December 1, 2003;
97(6):
1795 - 1799.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Sarvela, P. Halonen, A. Soikkeli, and K. Korttila
A Double-Blinded, Randomized Comparison of Intrathecal and Epidural Morphine for Elective Cesarean Delivery
Anesth. Analg.,
August 1, 2002;
95(2):
436 - 440.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. S. Khaw, W. D. Ngan Kee, M. Wong, F. Ng, and A. Lee
Spinal Ropivacaine for Cesarean Delivery: A Comparison of Hyperbaric and Plain Solutions
Anesth. Analg.,
March 1, 2002;
94(3):
680 - 685.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|