JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cuignet, O. Y.
Right arrow Articles by Spiess, B. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cuignet, O. Y.
Right arrow Articles by Spiess, B. D.
Anesth Analg 2000;90:517-522
© 2000 International Anesthesia Research Society


CARDIOVASCULAR ANESTHESIA

A Second-Generation Blood Substitute (Perfluorodichlorooctane Emulsion) Generates Spurious Elevations in Platelet Counts from Automated Hematology Analyzers

Olivier Y. Cuignet, MD*,{ddagger}, Brent L. Wood, MD, PhD{dagger}, Wayne L. Chandler, MD{dagger}, and Bruce D. Spiess, MD*

Departments of *Anesthesiology and {dagger}Laboratory Medicine, University of Washington, Seattle, Washington; and {ddagger}Department of Anesthesiology, Cliniques Universitaires Saint Luc, Université Catholique de Louvain, Brussels, Belgium

Address correspondence and reprint requests to Olivier Y. Cuignet, MD, Departement d’Anesthesiologie, Université Catholique de Louvain, Cliniques Universitaires Saint Luc, Avenue Hippocrate 10, 1200 Brussels, Belgium.

Perfluorocarbon emulsions (PFEs) appear as platelets in automated cell counters, which may affect samples from thrombocytopenic patients (less than 100,000/µL). Therefore, we mixed clinically relevant concentrations of perfluorodichlorooctane (Oxyfluor®; Hemagen, Inc., St. Louis, MO) in vitro with whole blood samples ranging from 0 to 150,000 platelets/µL and compared a new counter that uses optical platelet recognition (Abbott CellDyn 3200; Santa Clara, CA) with conventional electroimpedance-based counters (Abbott CellDyn 3500 and CellDyn 1700). We found that emulsion particles appear as small-sized platelets either in diluent or in blood. The emulsion results in a reproducible overestimate of the platelet counts, of greater importance as PFE concentration increases, and as the actual platelet count of the blood samples decreases. The new optical technology yields smaller overestimates but, even at low PFE concentrations, gives an unacceptable relative error at platelet counts near the transfusion thresholds recommended by the American Society of Anesthesiologists guidelines for blood component therapy. Unexpected interference in the leukocyte and erythrocyte channels is also reported. Experimental limitations preclude extrapolation of these findings to other automated cell counters, because differences in technology or software may affect their capacity to separate PFE particles from platelets.

Implications: Perfluorocarbons are being investigated under conditions in which thrombocytopenia is likely to occur. In this in vitro study, we demonstrate significant overestimates in platelet counts from automated cell counters at clinically relevant perfluorocarbon concentrations in thrombocytopenic blood samples.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
A. A. Ali, G. S. Ali, J. M. Steinke, and A. P. Shepherd
Co-Oximetry Interference by Hemoglobin-Based Blood Substitutes
Anesth. Analg., April 1, 2001; 92(4): 863 - 869.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2000 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2000 by the International Anesthesia Research Society.