JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tanaka, M.
Right arrow Articles by Nishikawa, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tanaka, M.
Right arrow Articles by Nishikawa, T.
Related Collections
Right arrow Regional Anesthesia
Right arrow Pharmacology
Anesth Analg 2001;93:1612-1617
© 2001 International Anesthesia Research Society


REGIONAL ANESTHESIA

The Efficacy of Simulated Intravascular Test Dose in Sedated Patients

Makoto Tanaka, MD, Masayoshi Sato, MD, Tetsu Kimura, MD, and Toshiaki Nishikawa, MD

Department of Anesthesia, Akita University School of Medicine, Akita-City, Japan

Address correspondence and reprint requests to Makoto Tanaka, MD, Department of Anesthesia, Akita University School of Medicine, Hondo 1-1-1, Akita-City, Akita 010-8543, Japan. Address e-mail to mtanaka{at}med.akita-u.ac.jp

Sedation usually decreases the reliability of subjectively detecting an intravascular test dose, but the efficacies of objective hemodynamic and T-wave criteria remain undetermined. Sixty healthy patients were randomly assigned to receive IV midazolam in 1-mg increments until they were lightly sedated, fentanyl 2 µg/kg followed by incremental midazolam until they were similarly sedated, or no sedative (n = 20 each). Then, normal saline 3 mL was administered IV, followed 4 min later by 1.5% lidocaine 3 mL plus epinephrine 15 µg (1:200,000) in all subjects. Heart rate (HR), systolic blood pressure (SBP) measured by a radial arterial catheter, and lead II of the electrocardiogram were continuously recorded for 4 min after the saline and test dose injections. An IV test dose produced significant increases in HR and SBP and decreases in T-wave amplitude in all subjects. However, the mean maximum increase in HR in patients sedated with midazolam plus fentanyl (31 ± 14 bpm [mean ± SD]) was significantly less than in those administered midazolam alone or no sedative (42 ± 12 and 44 ± 10 bpm, respectively; P < 0.05). A sensitivity of 100% was obtained on the basis of the traditional HR criterion (positive if >=20 bpm increase) in patients sedated with midazolam or no sedative, but it was 70% in those with midazolam plus fentanyl (P < 0.05 versus the other two groups). Irrespective of the treatment, sensitivities and specificities of 100% were obtained according to the SBP (positive if >=15 mm Hg increase) and T-wave (positive if >=25% decrease in amplitude) criteria. An increase in SBP and a decrease in T-wave amplitude are more reliable than an HR response for detecting accidental intravascular injection of the epinephrine-containing test dose in subjects sedated with midazolam and fentanyl.

IMPLICATIONS: To determine whether an epidural catheter is in a blood vessel, an epidural test dose containing 15 µg epinephrine is used. We found that an increase in systolic blood pressure and a decrease in T-wave amplitude seem to be more reliable than a heart rate change for detecting inadvertent intravascular injection of an epinephrine-containing test dose in patients sedated with midazolam and fentanyl.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. Guay
The epidural test dose: a review.
Anesth. Analg., March 1, 2006; 102(3): 921 - 929.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. M. Klein, T. Pierce, Y. Rubin, K. C. Nielsen, and S. M. Steele
Successful Resuscitation After Ropivacaine-Induced Ventricular Fibrillation
Anesth. Analg., September 1, 2003; 97(3): 901 - 903.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
K. Ogasawara, M. Tanaka, and T. Nishikawa
Choice of Electrocardiography Lead Does Not Affect the Usefulness of the T-Wave Criterion for Detecting Intravascular Injection of an Epinephrine Test Dose in Anesthetized Children
Anesth. Analg., August 1, 2003; 97(2): 372 - 376.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Tanaka and T. Nishikawa
Does the Choice of Electrocardiography Lead Affect the Efficacy of the T-Wave Criterion for Detecting Intravascular Injection of an Epinephrine Test Dose?
Anesth. Analg., November 1, 2002; 95(5): 1408 - 1411.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2001 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2001 by the International Anesthesia Research Society.