JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Diemunsch, P. A.
Right arrow Articles by Geny, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Diemunsch, P. A.
Right arrow Articles by Geny, B.
Related Collections
Right arrow Anesthetic Techniques
Anesth Analg 2002;94:1014-1018
© 2002 International Anesthesia Research Society


GENERAL ARTICLES

Calibrated Pneumoperitoneal Venting to Prevent N2O Accumulation in the CO2 Pneumoperitoneum During Laparoscopy with Inhaled Anesthesia: An Experimental Study in Pigs

Pierre A. Diemunsch, MD*, Thomas Van Dorsselaer*, Klaus D. Torp, MD*, Roland Schaeffer, MD*, and Bernard Geny, MD, PhD{dagger}

*Département d’Anesthésiologie, I.R.C.A.D., Hôpitaux Universitaires, Strasbourg, France; and {dagger}Institut de Physiologie, Faculté de Médecine, Strasbourg, France

Address correspondence and reprint requests to Pierre A. Diemunsch, MD, I.R.C.A.D., Hôpitaux Universitaires, 1, Place de l’Hôpital, 67000 Strasbourg, France.

Nitrous oxide (N2O) accumulates in the CO2 pneumoperitoneum during laparoscopy when N2O is used as an adjuvant for inhaled anesthesia. This may worsen the consequences of gas embolism and introduce a fire risk. In this study, we quantified the pneumoperitoneal gas venting necessary to prevent significant contamination by inhaled N2O. Four domestic pigs (26–30 kg) were anesthetized and ventilated with 66% N2O in oxygen. A CO2 pneumoperitoneum was insufflated and maintained at a pressure of 12 mm Hg. Each animal underwent three experimental conditions, in random sequence, for 70 min each: 1) no pneumoperitoneal leak, 2) leak of 2 L every 10 min (12 L/h), and 3) leak of 4 L every 10 min (24 L/h). Every 10 min, pneumoperitoneal gas samples were analyzed for fractions (FPn) of N2O and CO2. Without leaks, FPnN2O increased continually and reached 29.58% ± 3.15% at 70 min. With leaks of 2 and 4 L every 10 min (12 and 24 L/h), FPnN2O reached a plateau of <10% after 30 min. We conclude that calibrated pneumoperitoneal venting of 12 or 24 L/h is enough to prevent the constitution of potentially dangerous pneumoperitoneal gas mixtures if venting is constant.

IMPLICATIONS: External venting calibrated at four or eight initial pneumoperitoneal volumes per hour with compensation by fresh CO2 is sufficient to prevent nitrous oxide buildup of more than 10% in the pneumoperitoneum during laparoscopy with inhaled general anesthesia if venting is constant.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2002 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press