JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tung, A.
Right arrow Articles by Morgan, S. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tung, A.
Right arrow Articles by Morgan, S. E.
Related Collections
Right arrow Critical Care
Right arrow Airway

Anesth Analg 2002;95:192-197
© 2002 International Anesthesia Research Society


CRITICAL CARE AND TRAUMA

Modeling the Effect of Progressive Endotracheal Tube Occlusion on Tidal Volume in Pressure-Control Mode

Avery Tung, MD*, and Sherwin E. Morgan, RRT{dagger}

Departments of *Anesthesia and Critical Care and {dagger}Respiratory Therapy, University of Chicago, Chicago, Illinois

Address correspondence and reprint requests to Avery Tung, MD, Department of Anesthesia and Critical Care, The University of Chicago, Chicago, IL 60637. Address e-mail to atung@ airway.uchicago.edu.

A recognized hazard of prolonged endotracheal intubation is progressive airway occlusion resulting from deposition of secretions on the inner surface of the endotracheal tube (ETT). When volume-controlled ventilation is used, progressive ETT occlusion may be detected by monitoring the difference between peak and plateau airway pressures. In pressure-controlled modes, however, inspiratory airway pressures are preset and thus cannot act as a warning indicator. Instead, changes in delivered tidal volumes may aid the diagnosis of ETT occlusion. To determine whether tidal volume monitoring effectively de-tects progressive ETT occlusion, we mathematically modeled the response of a ventilator operating in pressure-controlled mode to increasing airway resistance. To corroborate our model, we then bench-tested the Siemens 300 and Puritan-Bennett 7200 ventilators by using a test lung and a series of ETTs ranging in size from 9.0 to 3.5 mm inner diameter to simulate progressive occlusion. We found that when pressure-controlled mode was used, progressive ETT occlusion did not reduce delivered tidal volumes until occlusion was nearly complete. We conclude that prolonged use of pressure-controlled mode may allow significant ETT obstruction to build up undetected, risking complete ETT occlusion and complicating the perioperative care of patients ventilated with this mode.

IMPLICATIONS: Although increasing airway pressures during volume-controlled ventilation allow early recognition of endotracheal tube (ETT) obstruction, airway pressures with pressure-controlled ventilation are fixed. We found during tests of two intensive care unit ventilators that although ETT obstruction reduces delivered tidal volumes during pressure-controlled ventilation, reductions do not occur until occlusion is advanced.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
R. K. Visaria and D. R. Westenskow
Model-Based Detection of Endobronchial Intubation
Anesth. Analg., October 1, 2006; 103(4): 888 - 893.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
R. Kawati, L. Vimlati, J. Guttmann, G. Hedenstierna, U. Sjostrand, S. Schumann, and M. Lichtwarck-Aschoff
Change in expiratory flow detects partial endotracheal tube obstruction in pressure-controlled ventilation.
Anesth. Analg., September 1, 2006; 103(3): 650 - 657.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2002 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press