Anesth Analg 2002;95:524-530
© 2002 International Anesthesia Research Society
CARDIOVASCULAR ANESTHESIA
Mitral Flow Propagation Velocity Identifies Patients with Abnormal Diastolic Function During Coronary Artery Bypass Graft Surgery
George N. Djaiani, MD DEAA, FRCA,
Brian J. McCreath, MBChB BSc, FRCA,
Lian K. Ti, MD,
Burkhard G. Mackensen, MD,
Mihai Podgoreanu, MD,
Barbara Phillips-Bute, PhD, and
Joseph P. Mathew, MD
Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina
Address correspondence and reprint requests to Joseph P. Mathew, MD, Department of Anesthesiology, PO Box 3094, Duke University Medical Center, Durham, NC 27710. Address e-mail to mathe014{at}mc.duke.edu
Flow propagation velocity (Vp) is a new method of assessing left ventricular (LV) diastolic (D) function that seems to be insensitive to heart rate and preload changes. We hypothesized that Vp <50 cm/s identifies patients with D dysfunction and that Vp provides an assessment of D function when standard Doppler techniques are uninterpretable. We conducted a prospective Doppler echocardiographic assessment of D function in 63 patients undergoing coronary artery bypass graft surgery. Doppler derivatives of mitral inflow and pulmonary vein flow profiles as well as isovolumic relaxation time were compared with Vp before and after cardiopulmonary bypass. A Valsalva maneuver was used to decrease preload. All patients with D dysfunction had Vp <50 cm/s. A Valsalva maneuver did not affect Vp. Vp remained a reliable measure of LV D function when mitral flow profiles could not be determined because of changes in heart rate and rhythm. LV filling patterns did not change significantly after cardiopulmonary bypass. We conclude that Vp is a simple measure of D function during coronary artery bypass graft surgery that correlates with standard, load-dependent Doppler echocardiographic techniques to identify D dysfunction. Vp <50 cm/s identifies abnormal D function in this patient population.
IMPLICATIONS: Mitral propagation velocity (Vp) is a simple, reproducible measure of diastolic function during coronary artery bypass graft surgery that correlates with standard Doppler echocardiographic techniques to identify dysfunction in the setting of a rapid heart rate or variable preload. Vp <50 cm/s identifies abnormal diastolic function in this patient population.
This article has been cited by other articles:

|
 |

|
 |
 
Y. Shi, A. Y. Denault, P. Couture, A. Butnaru, M. Carrier, and J.-C. Tardif
Biventricular diastolic filling patterns after coronary artery bypass graft surgery
J. Thorac. Cardiovasc. Surg.,
May 1, 2006;
131(5):
1080 - 1086.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. W.L. De Boeck, J. K. Oh, P. M. Vandervoort, J. A. Vierendeels, R. P.L.M. van der Aa, and M.-J. M. Cramer
Colour M-mode velocity propagation: a glance at intra-ventricular pressure gradients and early diastolic ventricular performance
Eur J Heart Fail,
January 1, 2005;
7(1):
19 - 28.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. A. Fox, V. Formanek, A. Friedrich, and S. K. Shernan
Intraoperative Echocardiography
Card. Surg. Adult,
January 1, 2003;
2(2003):
283 - 314.
[Full Text]
|
 |
|
|