JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sukernik, M. R.
Right arrow Articles by Bennett-Guerrero, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sukernik, M. R.
Right arrow Articles by Bennett-Guerrero, E.
Related Collections
Right arrow Heart
Right arrow Monitoring (Cardiac)

Anesth Analg 2002;95:1142-1146
© 2002 International Anesthesia Research Society


CARDIOVASCULAR ANESTHESIA

The Impact of Newly Diagnosed Patent Foramen Ovale in Patients Undergoing Off-Pump Coronary Artery Bypass Grafting: Case Series of Eleven Patients

M. R. Sukernik, MD PhD*, B. Mets, MB ChB, PhD, FRCA*, B. Kachulis, MD*, M. C. Oz, MD{dagger}, and E. Bennett-Guerrero, MD*

Departments of *Anesthesiology and {dagger}Surgery, College of Physicians & Surgeons, Columbia University, New York, New York

Address correspondence and reprint requests to Mikhail R. Sukernik, MD, PhD, Department of Anesthesiology, College of Physicians & Surgeons, Columbia University, 622 West 168th St., New York, NY 10032. Address e-mail to mrs21{at}columbia.edu

The increased use of transesophageal echocardiography (TEE) by anesthesiologists may lead to an increase in the intraoperative detection of previously undiagnosed patent foramen ovale (PFO). The impact of heart manipulation on interatrial shunting through a PFO during off-pump coronary artery bypass graft (CABG) has not been studied. We retrospectively studied 11 patients with PFOs who underwent off-pump CABG. TEE contrast studies and blood gas analyses were performed at baseline, during heart elevation for distal coronary arteries anastomoses, and at the end of the surgery. At baseline, 5 of 11 patients had left-to-right shunting and 2 of 11 had right-to-left shunting. Heart elevation did not result in oxygen desaturation in any patient; however, it caused the disappearance of a right-to-left shunt (n = 1), persistence of this shunt (n = 1), and the development of a new right-to-left shunt (n = 2). Return of the heart to its original position resulted in a return of TEE findings to the baseline state in all patients. This series suggests that off-pump CABG can be performed safely in the majority of patients with PFOs; however, additional investigation is needed to assure that adverse effects do not occur in a subset of patients undergoing off-pump CABG in the presence of a PFO.

IMPLICATIONS: This case series suggests that coronary artery bypass graft surgery can be safely performed in most patients with patent foramen ovale without the use of a cardiopulmonary bypass.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2002 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2002 by the International Anesthesia Research Society.