JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dimitriou, V.
Right arrow Articles by Brimacombe, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dimitriou, V.
Right arrow Articles by Brimacombe, J.
Related Collections
Right arrow Airway

Anesth Analg 2003;96:1214-1217
© 2003 International Anesthesia Research Society


GENERAL ARTICLES

A Comparison of the PAxpressTM and Face Mask Plus Guedel Airway by Inexperienced Personnel After Mannequin-Only Training

V. Dimitriou, MD DEAA*, G. S. Voyagis, MD{dagger}, C. Iatrou, MD*, and J. Brimacombe, MB ChB, FRCA, MD{ddagger}

*Department of Anaesthesia, University of Thrace; {dagger}Department of Anaesthesia, Sotiria Hospital, Greece; and {ddagger}Department of Anaesthesia and Intensive Care, University of Queensland and James Cook University, Cairns Base Hospital, Australia

Address correspondence and reprint requests to J. Brimacombe, MD, Department of Anesthesia and Intensive Care, Cairns Base Hospital, The Esplanade, Cairns 4870, Australia. Address e-mail to jbrimacombe{at}austarnet.com.au

The PAxpressTM (PAX) is a new extraglottic airway device consisting of an anatomically curved tube, an inflatable circular cuff in the midsection, a noninflatable gilled conical cuff at the distal end, and an anterior-facing, rectangular hooded vent between the two cuffs. We compared the ability of nurses with no previous airway management experience to ventilate the lungs of 45 ASA physical status I and II anesthetized, paralyzed patients using either the PAX or face mask and Guedel airway (FM/GA) after mannequin-only training. Nurses were asked to ventilate the patient to an expired target tidal volume of 7 mL/kg and then to the maximum tidal volume achievable. The FM/GA was used first and the then the PAX. The target tidal volume was achieved in all patients with both devices. There were no differences in the time taken (PAX, 41 ± 15 s; FM/GA, 39 ± 25 s) or the number of insertion attempts to achieve the target tidal volume. There were no differences in the frequency of esophageal leaks at the target (PAX, 9%; FM/GA, 4%) and maximum tidal volume (PAX, 51%; FM/GA, 49%). The maximal tidal volume (1261 ± 306 versus 958 ± 220 mL; P < 0.0001) and peak airway pressure (37 ± 5 versus 28 ± 6 cm H2O; P < 0.0001) was larger for the PAX, but blood was detected more frequently (22% versus 0%; P = 0.001). We conclude that ventilation to a target tidal volume of 7 mL/kg in anesthetized, paralyzed adults is equally successful for the PAX and FM/GA by inexperienced nurses after mannequin-only training. However, the maximal tidal volume and peak airway pressure is larger and airway trauma more common with the PAX.

IMPLICATIONS: Ventilation to a target tidal volume of 7 mL/kg in anesthetized, paralyzed adults is equally successful for the PAxpressTM (PAX) and Face Mask/Guedel Airway by inexperienced nurses after mannequin-only training. However, the maximal tidal volume and peak airway pressure is larger and airway trauma more common with the PAX.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2003 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press