JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schumann, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schumann, R.
Related Collections
Right arrow Blood
Right arrow Surgery
Right arrow Cardiovascular
Right arrow Economics and Health Care Research

Anesth Analg 2003;97:21-28
© 2003 International Anesthesia Research Society


PEDIATRIC ANESTHESIA

Intraoperative Resource Utilization in Anesthesia for Liver Transplantation in the United States: A Survey

Roman Schumann, MD

Department of Anesthesiology, Division of Liver Transplant Anesthesia, Tufts–New England Medical Center, Boston, Massachusetts

Address correspondence and reprint requests to Roman Schumann, MD, Tufts–New England Medical Center, Department of Anesthesiology, #298, 750 Washington St., Boston, MA 02111. Address e-mail to RSchumann{at}tufts-nemc.org

Among the intraoperative resources expended for liver transplantation, laboratory tests, personnel, high-flow infusion devices, high-tech monitoring equipment, and veno-venous bypass vary from institution to institution. Although of obvious interest to the anesthesia liver transplantation community and others, little is known regarding current utilization of these resources on a national level. To determine the resource utilization among liver transplantation centers in the United States, we conducted a national survey between April and July 2002. Results were stratified according to pediatric versus adult recipient populations and transplantation case volume. Of 99 centers that received the survey by mail, 66 (66.6%) responded. Pediatric liver transplantation programs were distinctly different in personnel, equipment, monitoring, and veno-venous bypass utilization when compared with adult or mixed-age programs. Among laboratory studies, statistically significant trends emerged for fewer intraoperative determinations of the activated clotting time, magnesium, and phosphate with increasing transplantation volume. The results describe national practice patterns and may be useful for programs to compare their approaches and develop clinical pathways. There is wide variation of resource use between centers. The survey results do not consistently correlate with the few recommendations found in the current literature.

IMPLICATIONS: Currently no comprehensive data are available describing the intraoperative use of laboratory tests, personnel, infusion and perfusion equipment, monitoring technology, and veno-venous bypass by liver transplantation programs. These postal survey results provide an overview of utilization of these resources in anesthesia for liver transplantation.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
M. T. Ganter and C. K. Hofer
Coagulation Monitoring: Current Techniques and Clinical Use of Viscoelastic Point-of-Care Coagulation Devices
Anesth. Analg., May 1, 2008; 106(5): 1366 - 1375.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. Y. Findlay, B. Gali, M. T. Keegan, C. M. Burkle, and D. J. Plevak
Vasotrac(R) arterial blood pressure and direct arterial blood pressure monitoring during liver transplantation.
Anesth. Analg., March 1, 2006; 102(3): 690 - 693.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
D. Jackson, A. Botea, Y. Gubenko, E. Delphin, and H. Bennett
Successful intraoperative use of recombinant tissue plasminogen activator during liver transplantation complicated by massive intracardiac/pulmonary thrombosis.
Anesth. Analg., March 1, 2006; 102(3): 724 - 728.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
Z. Jankovic, A. Boon, and R. Prasad
Fatal haemothorax following large-bore percutaneous cannulation before liver transplantation
Br. J. Anaesth., October 1, 2005; 95(4): 472 - 476.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2003 by the International Anesthesia Research Society.