JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swaminathan, M.
Right arrow Articles by Mathew, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swaminathan, M.
Right arrow Articles by Mathew, J. P.
Related Collections
Right arrow Heart
Right arrow Monitoring (Cardiac)

Anesth Analg 2003;97:642-647
© 2003 International Anesthesia Research Society


CARDIOVASCULAR ANESTHESIA

An Assessment of Two Different Methods of Left Ventricular Ejection Time Measurement by Transesophageal Echocardiography

Madhav Swaminathan, MD, Barbara G. Phillips-Bute, PhD, and Joseph P. Mathew, MD

Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina

Address correspondence and reprint requests to Madhav Swaminathan, MD, Department of Anesthesiology, Box 3094, Duke University Medical Center, Durham, NC 27710. Address e-mail to swami001{at}mc.duke.edu

Left ventricular ejection time (LVET) is an important component in evaluating left ventricular performance. This measurement is usually made by measuring the timing of the transaortic valve flow velocity by continuous-wave Doppler. Although M-mode has also been used for measuring LVET, it has not been compared with the Doppler method. We tested the hypothesis that the M-mode-measured duration of aortic valve opening is comparable to Doppler-derived measurement of LVET by transesophageal echocardiography (TEE). Measurements were made in 31 patients undergoing nonaortic valve cardiac surgery. The timing of transaortic flow by continuous-wave Doppler was compared with the M-mode-derived timing of aortic valve opening. There was close correlation (Pearson correlation coefficient, r = 0.86; P < 0.0001) between M-mode and Doppler measurements. There was no significant difference between the two techniques by linearity tests (P > 0.1). Bland-Altman analysis showed no significant bias. We confirmed the hypothesis that M-mode-derived measurement of LVET is comparable to Doppler-derived measurement of LVET. M-mode may be an acceptable alternative to the Doppler method, especially when transvalvular velocity gradients cannot be readily obtained. M-mode is a simple, yet often underused, method of evaluating LVET during TEE.

IMPLICATIONS: Left ventricular ejection time is an important component of cardiac function assessment. Using transesophageal echocardiography, we found that the M-mode modality is comparable to Doppler assessment in determining ejection time and is a useful alternative when Doppler velocity gradients cannot be easily obtained.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2003 by the International Anesthesia Research Society.