| ||||||||||||||
|
|
|||||||||||||
From the Department of Anesthesiology and Pain Management University of Texas Southwestern Medical Center at Dallas
Address correspondence to Dr. Paul F. White, Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 753909068. Address email to paul.white{at}utsouthwestern.edu
The use of cerebral monitoring may improve the ability of anesthesiologists to titrate anesthetic drugs. However, there is controversy regarding the impact of the alleged anesthetic-sparing effects of cerebral monitoring on the recovery process and patient outcome. We designed this prospective double-blinded, sham-controlled study to evaluate the impact of intraoperative monitoring with the electroencephalogram bispectral index (BISTM) or auditory evoked potential (AEP) device on the usage of desflurane and the time to discharge from the recovery room, as well as on patient satisfaction with their anesthetic experience and recovery. Ninety healthy patients undergoing laparoscopic general surgery procedures using a standardized anesthetic technique were randomly assigned to one of three monitoring groups: standard clinical practice (control), BIS-guided, or AEP-guided. Both the BIS and AEP monitors were connected to all patients before induction of general anesthesia. In the control group, the anesthesiologists were not permitted to observe the BIS or AEP index values during the intraoperative period. In the BIS-guided group, the volatile anesthetic was titrated to maintain a BIS value in the range of 4555. In the AEP-guided group, the targeted AEP index range was 1520. The BIS and AEP indices, as well as end-tidal desflurane concentration, were recorded at 35 min intervals. Recovery times to awakening, tracheal extubation, fast-track score
12, and postanesthesia care unit (PACU) discharge criteria were recorded at 110 min intervals. In addition, patient satisfaction with anesthesia and quality of recovery were evaluated on 100- and 18-point scales, respectively, at 24 h after surgery. The AEP- and BIS-guided groups were administered significantly smaller average end-tidal desflurane concentrations than the control group (3.8 ± 0.9 and 3.9 ± 0.6 versus 4.7 ± 1.7, respectively) (P < 0.01). Although the emergence times to eye opening, tracheal extubation, and obeying commands were consistently shorter in the AEP and BIS groups (6 ± 4 and 6 ± 5 versus 8 ± 8 min; 6 ± 5 and 6 ± 4 versus 11 ± 10 min; and 8 ± 4 and 7 ± 4 versus 12 ± 9 min, respectively), only the extubation times were significantly different from the control group (P < 0.05). More importantly, the length of the PACU stay was significantly shorter in both the AEP- and BIS-guided groups (79 ± 43 and 80 ± 47 versus 108 ± 58 min, respectively) (P < 0.05). The patients quality of recovery was also significantly higher in the two monitored groups (15 ± 2 versus 13 ± 3 in the control group, P < 0.05). We concluded that cerebral monitoring with either the BIS or AEP devices reduced the maintenance anesthetic (desflurane) requirement, resulting in a shorter length of stay in the PACU and improved quality of recovery after laparoscopic surgery. However, there were no significant outcome differences between the two cerebral monitored groups.
IMPLICATIONS: Compared with standard monitoring practices, use of an auditory evoked potential or bispectral index monitor to titrate the volatile anesthetic led to a significant reduction in the anesthetic requirement. The anesthetic-sparing effect of cerebral monitoring resulted in a shorter postanesthesia care unit stay and improved quality of recovery from the patients perspective.
This article has been cited by other articles:
![]() |
T. Nishiyama The Effects of Auditory Evoked Potential Click Sounds on Bispectral Index and Entropy Anesth. Analg., August 1, 2008; 107(2): 545 - 548. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Avidan, L. Zhang, B. A. Burnside, K. J. Finkel, A. C. Searleman, J. A. Selvidge, L. Saager, M. S. Turner, S. Rao, M. Bottros, et al. Anesthesia Awareness and the Bispectral Index N. Engl. J. Med., March 13, 2008; 358(11): 1097 - 1108. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Aime, N. Verroust, C. Masson-Lefoll, G. Taylor, P.-A. Laloe, N. Liu, and M. Fischler Does Monitoring Bispectral Index or Spectral Entropy Reduce Sevoflurane Use? Anesth. Analg., December 1, 2006; 103(6): 1469 - 1477. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Zohar, I. Luban, P. F. White, E. Ramati, S. Shabat, and B. Fredman Bispectral index monitoring does not improve early recovery of geriatric outpatients undergoing brief surgical procedures: [Le monitorage avec l'index bispectral n'ameliore pas la recuperation precoce des patients ambulatoires ages apres une operation breve] Can J Anesth, January 1, 2006; 53(1): 20 - 25. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. F. White, J. Tang, G. F. Romero, R. H. Wender, R. Naruse, A. Sloninsky, and R. Kariger A Comparison of State and Response Entropy Versus Bispectral Index Values During the Perioperative Period Anesth. Analg., January 1, 2006; 102(1): 160 - 167. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Bruhn, S. Kreuer, P. Bischoff, P. Kessler, G. N. Schmidt, A. Grzesiak, and W. Wilhelm Bispectral index and A-line AAI index as guidance for desflurane-remifentanil anaesthesia compared with a standard practice group: a multicentre study Br. J. Anaesth., January 1, 2005; 94(1): 63 - 69. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. F. White, J. Tang, H. Ma, R. H. Wender, A. Sloninsky, and R. Kariger Is the Patient State Analyzer with the PSArray2 a Cost-Effective Alternative to the Bispectral Index Monitor During the Perioperative Period? Anesth. Analg., November 1, 2004; 99(5): 1429 - 1435. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Sneyd Editorial III: Remembering awareness Br. J. Anaesth., September 1, 2004; 93(3): 324 - 326. [Full Text] [PDF] |
||||
|