Anesth Analg 2004;98:491-496
© 2004 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000097182.21374.DE
OBSTETRIC ANESTHESIA
Sensorimotor Anesthesia and Hypotension After Subarachnoid Block: Combined Spinal-Epidural Versus Single-Shot Spinal Technique
Raymond Wee-Lip Goy, MMed, and
Alex Tiong-Heng Sia, MMed
From the Department of Anesthesia, KK Womens and Childrens Hospital, Singapore
Address correspondence and reprint requests to Raymond W. Goy, Department of Anesthesia, KK Womens and Childrens Hospital, 100 Bukit Timah Road, Singapore 229 899. Address email to raygoywl{at}singnet.com.sg
The extent of the intrathecal compartment depends on the balance between cerebrospinal fluid and subatmospheric epidural pressure. Epidural insertion disrupts this relationship, and the full impact of loss-of-resistance on the qualities of subarachnoid block is unknown. In this study we sought to determine if subarachnoid block, induced by combined spinal-epidural (CSE) using loss-of-resistance to air could render higher sensory anesthesia than single-shot spinal (SSS) when an identical mass of intrathecal anesthetic was injected. Sixty patients, scheduled for minor gynecological procedures, were randomly allocated into three groups all receiving 10 mg of 0.5% hyperbaric bupivacaine. In the SSS group, intrathecal administration was through a 27-gauge Whitacre spinal needle inserted at the L3-4 level. For the CSE group, the epidural space was identified with an 18-gauge Tuohy needle using loss-of-resistance to 4 mL of air. After intrathecal administration, a 20-gauge catheter was left in the epidural space. No further drug or saline was administered through the catheter. The procedure was repeated in group CSE (no-catheter) except without insertion of a catheter. Sensorimotor anesthesia was assessed at regular 2.5-min intervals until T10 was reached. In all aspects, there was no difference between CSE and CSE (no-catheter). Peak sensory level in SSS was lower than CSE and CSE (no-catheter) (median T5 [max T3min T6] versus (T3 [T14] and (T3 [T25]) (P < 0.01). During the first 10 min postblock, dermatomal thoracic block was the lowest in SSS (P < 0.05). Time for regression of sensory level to T10 was also shortest in SSS. Hypotension, ephedrine use and period of motor recovery were more pronounced in CSE and CSE (no-catheter). We conclude that subarachnoid block induced by CSE produces greater sensorimotor anesthesia and prolonged recovery compared with SSS. There is also a more frequent incidence of hypotension and vasoconstrictor use despite using identical doses and baricity of local anesthetic.
IMPLICATIONS: This study confirms that induction of subarachnoid block by a combined-spinal epidural technique produces a greater sensorimotor anesthesia and results in prolonged recovery when compared with a single-shot spinal technique. There is a more frequent incidence of hypotension and vasoconstrictor administration despite identical doses of intrathecally administered local anesthetic.
This article has been cited by other articles:

|
 |

|
 |
 
S. Leo, B. L. Sng, Y. Lim, and A. T. H. Sia
A Randomized Comparison of Low Doses of Hyperbaric Bupivacaine in Combined Spinal-Epidural Anesthesia for Cesarean Delivery
Anesth. Analg.,
November 1, 2009;
109(5):
1600 - 1605.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. J. Horstman, E. T. Riley, and B. Carvalho
A Randomized Trial of Maximum Cephalad Sensory Blockade with Single-Shot Spinal Compared with Combined Spinal-Epidural Techniques for Cesarean Delivery
Anesth. Analg.,
January 1, 2009;
108(1):
240 - 245.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Ithnin, Y. Lim, A. T. Sia, and C. E. Ocampo
Combined Spinal Epidural Causes a Higher Level of Block than Equivalent, Single-Shot Spinal Anesthesia in Elective Cesarean Patients
Anesth. Analg.,
March 1, 2007;
104(3):
746 - 746.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. Lim, W. Teoh, and A. T. Sia
Combined Spinal Epidural Does Not Cause a Higher Sensory Block than Single Shot Spinal Technique for Cesarean Delivery in Laboring Women
Anesth. Analg.,
December 1, 2006;
103(6):
1540 - 1542.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Ithnin, Y. Lim, A. T. Sia, and C. E. Ocampo
Combined Spinal Epidural Causes Higher Level of Block than Equivalent Single-Shot Spinal Anesthesia in Elective Cesarean Patients
Anesth. Analg.,
February 1, 2006;
102(2):
577 - 580.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. W.-L. Goy, Y. Chee-Seng, A. T.-H. Sia, K. Choo-Kok, and S. Liang
The Median Effective Dose of Intrathecal Hyperbaric Bupivacaine Is Larger in the Single-Shot Spinal as Compared with the Combined Spinal-Epidural Technique
Anesth. Analg.,
May 1, 2005;
100(5):
1499 - 1502.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|