JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Robertson, F. A.
Right arrow Articles by Hoffman, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Robertson, F. A.
Right arrow Articles by Hoffman, G. M.
Related Collections
Right arrow Equipment
Right arrow Monitoring (Non-cardiac)
Right arrow Pediatrics

Anesth Analg 2004;98:617-622
© 2004 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000101601.43781.15


PEDIATRIC ANESTHESIA

Clinical Evaluation of the Effects of Signal Integrity and Saturation on Data Availability and Accuracy of Masimo SET® and Nellcor N-395 Oximeters in Children

Frederick A. Robertson, MD, and George M. Hoffman, MD Section Editor

From the Department of Pediatric Anesthesiology, Children’s Hospital of Wisconsin, and the Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, Wisconsin

Address correspondence to Frederick A. Robertson, MD, Children’s Hospital of Wisconsin, PO Box 1997, Milwaukee, WI 53201. Address email to frobertson{at}wi.rr.com

Pulse oximetry manufacturers have introduced technologies that claim improved detection of hypoxemic events. Because improvements in signal processing and data rejection algorithms may differentially affect data reporting, we compared the data reporting and signal heuristic performance and agreement among the Nellcor N-395, Masimo SET®, and GE Solar 8000 oximeters under a spectrum of conditions of signal integrity and arterial oxygen saturations. A blinded side-by-side comparison of technologies was performed in 27 patients, and data were analyzed for time of data availability, measures of agreement and signal heuristics, and warnings stratified by signal integrity and SpO2. The Solar 8000 had less total data dropout than either of the new technologies. Masimo’s LoSIQ (signal quality) heuristic rejected less data than Nellcor’s MOT/PS (motion/pulse search) flag. When no signal heuristic was displayed, there was little difference in precision and bias between the two newer technologies; however, agreement between devices deteriorated in the presence of SIQ, MOT, or hypoxemia. Both newer devices flagged questionable data, but their use of different rejection algorithms resulted in different probabilities of presenting data. Therefore, with poor SIQ or during hypoxemia, the Nellcor N-395 and Masimo oximeters are not clinically equivalent to each other or to the older Solar 8000 oximeter.

IMPLICATIONS: We compared new pulse oximeters from Nellcor and Masimo and found that, with good signal conditions, both new devices performed similarly to older technology. Overall, Masimo reported less data as questionable than Nellcor. With poor signal conditions or during hypoxemia, the new devices are not clinically equivalent to each other or to the older technology.




This article has been cited by other articles:


Home page
PediatricsHome page
A. Castillo, A. Sola, H. Baquero, F. Neira, R. Alvis, R. Deulofeut, and A. Critz
Pulse Oxygen Saturation Levels and Arterial Oxygen Tension Values in Newborns Receiving Oxygen Therapy in the Neonatal Intensive Care Unit: Is 85% to 93% an Acceptable Range?
Pediatrics, May 1, 2008; 121(5): 882 - 889.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2004 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2004 by the International Anesthesia Research Society.