JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chu, K.-S.
Right arrow Articles by Wu, J.-R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chu, K.-S.
Right arrow Articles by Wu, J.-R.
Related Collections
Right arrow Equipment
Right arrow Cardiovascular
Right arrow Heart
Right arrow Monitoring (Cardiac)

Anesth Analg 2004;98:910-914
© 2004 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000105865.94157.4C


CARDIOVASCULAR ANESTHESIA

Accurate Central Venous Port-A Catheter Placement: Intravenous Electrocardiography and Surface Landmark Techniques Compared by Using Transesophageal Echocardiography

Koung-Shing Chu, MD*, Jong-Hau Hsu, MD{dagger}, Shie-Shan Wang, MD{ddagger}, Chao-Shun Tang, PhD§, Kuang-I Cheng, MD§, Chien-Kuo Wang, MD||, and Jiunn-Ren Wu, MD{dagger}

*Department of Anesthesiology, Kuo General Hospital, Tainan, Taiwan; and Departments of {dagger}Pediatrics, {ddagger}Surgery, §Anesthesiology, and Medical Imaging, Kaohsiung Medical University, Kaohsiung City, Taiwan

Address correspondence and reprint requests to Kuang-I Cheng, MD, No. 100, Shih-Chuan 1st Rd., Department of Anesthesiology, Kaohsiung Medical University, Kaohsiung, Taiwan, Republic of China. Address e-mail to kuaich{at}kmu.edu.tw

Using transesophageal echocardiography (TEE) to locate the tip of central venous catheters inserted via the right subclavian vein, we compared IV electrocardiography (IV-ECG)-guided catheter tip placement with the conventional surface landmark technique. Sixty patients were randomly assigned into two groups. In Group E, the IV-ECG signal was conducted along an NaHCO3-filled catheter to facilitate catheter placement. In Group S, surface landmarks on the chest wall were used to determine the appropriate catheter length. The goal was to visualize the catheter tip with TEE at the superior edge of the crista terminalis, which is the junction of the superior vena cava (SVC) and right atrium (RA). The catheter tip position was considered to be satisfactory, as the tip was within 1.0 cm of the upper crista terminalis edge. All 30 Group E patients had satisfactory catheter tip placement when the ECG P wave was at its maximum. In contrast, 16 of the 30 patients in Group S had satisfactory tip positions (P < 0.001). All catheters were repositioned under TEE guidance to adjust the tip to the SVC-RA junction. After the catheter tips were confirmed to be located at the SVC-RA junction, the catheter tips were still visualized in the mid portion of RA in 12 of 60 patients on supine chest radiographs. We concluded that IV-ECG guidance to position a catheter resulted in satisfactory catheter tip placement that is in accordance with TEE views. Catheter placement at the SVC-RA junction with the surface landmark technique was unreliable.

IMPLICATIONS: Intravenous electrocardiography guidance to position catheters obtains a satisfactory catheter tip placement that is in accordance with transesophageal echocardiography views. The surface landmark technique does not result in reliable placement at the superior vena cava-right atrium junction.




This article has been cited by other articles:


Home page
Canadian J. AnesthesiaHome page
Y. Jeon, H.-G. Ryu, S.-Z. Yoon, J.-H. Kim, and J.-H. Bahk
Transesophageal echocardiographic evaluation of ECG-guided central venous catheter placement: [Evaluation echocardiographique transoesophagienne de la mise en place d'un catheter veineux central guidee par ECG].
Can J Anesth, October 1, 2006; 53(10): 978 - 983.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
R. H. E. Kerr and R. L. Applegate II
Accurate placement of the right atrial air aspiration catheter: a descriptive study and prospective trial of intravascular electrocardiography.
Anesth. Analg., August 1, 2006; 103(2): 435 - 8, table of contents.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2004 by the International Anesthesia Research Society.