JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Morimoto, Y.
Right arrow Articles by Sakabe, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morimoto, Y.
Right arrow Articles by Sakabe, T.
Related Collections
Right arrow Neuroanesthesia
Right arrow Monitoring (Non-cardiac)
Right arrow Technology
Right arrow Pharmacology

Anesth Analg 2004;98:1336-1340
© 2004 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000105867.17108.B6


TECHNOLOGY, COMPUTING, AND SIMULATION

The Relationship Between Bispectral Index and Electroencephalographic Parameters During Isoflurane Anesthesia

Yasuhiro Morimoto, MD*, Satoshi Hagihira, MD{dagger}, Yumika Koizumi, MD*, Kazuyoshi Ishida, MD*, Mishiya Matsumoto, MD*, and Takefumi Sakabe, MD*

*Department of Anesthesiology-Resuscitology, Yamaguchi University School of Medicine, Yamaguchi, Japan; and {dagger}Department of Anesthesiology, Osaka Prefectural Habikino Hospital, Osaka, Japan

Address correspondence and reprint requests to Yasuhiro Morimoto, MD, Department of Anesthesiology-Resuscitology, Yamaguchi University School of Medicine, 1-1-1 Minami-Kogushi Ube, Yamaguchi, 755-8505, Japan. Address e-mail to naa01346{at}nifty.ne.jp

Bispectral index (BIS) integrates various electroencephalographic (EEG) parameters into a single variable. However, the exact algorithm used to synthesize the parameters to BIS values is not known. The relationship between BIS and EEG parameters was evaluated during nitrous oxide/isoflurane anesthesia. Twenty patients scheduled for elective ophthalmic surgery were enrolled in the study. After EEG recording with a BIS monitor (A-1050) was begun, general anesthesia was induced and maintained with 0.5%–2% isoflurane and 66% nitrous oxide. Using software we developed, we continuously recorded BIS, spectral edge frequency 95% (SEF95), and EEG parameters such as relative beta ratio (BetaRatio), relative synchrony of fast and slow wave (SynchFastSlow), and burst suppression ratio. BetaRatio was linearly correlated with BIS (r = 0.90; P < 0.01; n = 253) at BIS more than 60. At a BIS range of 30 to 80, SynchFastSlow (r = 0.60; P < 0.01; n = 3314) and SEF95 (r = 0.75; P < 0.01; n = 3339) were linearly correlated with BIS. The correlation between BIS and SEF95 was significantly better than the correlation between BIS and SynchFastSlow (P < 0.01). At BIS less than 30, the burst suppression ratio was inversely linearly correlated with BIS (r = 0.76; P < 0.01; n = 65). At BIS less than 80, burst-compensated SEF95 was linearly correlated with BIS (r = 0.78; P < 0.01; n = 3404). In the range of BIS from 60 to 100, BIS can be calculated from BetaRatio. At surgical levels of anesthesia, BIS and SynchFastSlow (a parameter derived from bispectral analysis) or burst-compensated SEF95 (derived from power spectral analysis) are well correlated. However, our results show that SynchFastSlow has no advantage over SEF95 in calculation of BIS.

IMPLICATIONS: The relationship between bispectral index (BIS) and electroencephalographic parameters was evaluated during nitrous oxide/isoflurane anesthesia. At surgical levels of anesthesia, BIS and the relative synchrony of fast and slow wave (a parameter derived from bispectral analysis) or burst-compensated spectral edge frequency 95% (a parameter derived from power spectral analysis) are well correlated.




This article has been cited by other articles:


Home page
NEJMHome page
M. S. Avidan, L. Zhang, B. A. Burnside, K. J. Finkel, A. C. Searleman, J. A. Selvidge, L. Saager, M. S. Turner, S. Rao, M. Bottros, et al.
Anesthesia Awareness and the Bispectral Index
N. Engl. J. Med., March 13, 2008; 358(11): 1097 - 1108.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
Y. Morimoto, S. Hagihira, S. Yamashita, Y. Iida, M. Matsumoto, S. Tsuruta, and T. Sakabe
Changes in electroencephalographic bicoherence during sevoflurane anesthesia combined with intravenous fentanyl.
Anesth. Analg., September 1, 2006; 103(3): 641 - 645.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
V. Fodale, C. Pratico, M. Tescione, S. Tanania, T. Lucanto, and L. B. Santamaria
Tramadol does not modify the Bispectral Index during anaesthesia with sevoflurane and remifentanil
Br. J. Anaesth., August 1, 2005; 95(2): 212 - 215.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
H. Heller, R. Hatami, P. Mullin, R. R. Sciacca, A. G. Khandji, M. Hamberger, R. Emerson, and E. J. Heyer
Bilateral Bispectral Index Monitoring During Suppression of Unilateral Hemispheric Function
Anesth. Analg., July 1, 2005; 101(1): 235 - 341.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
Y. Morimoto, A. Matsumoto, Y. Koizumi, T. Gohara, T. Sakabe, and S. Hagihira
Changes in the Bispectral Index During Intraabdominal Irrigation in Patients Anesthetized with Nitrous Oxide and Sevoflurane
Anesth. Analg., May 1, 2005; 100(5): 1370 - 1374.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
Y. Morimoto, Y. Monden, K. Ohtake, T. Sakabe, and S. Hagihira
The Detection of Cerebral Hypoperfusion with Bispectral Index Monitoring During General Anesthesia
Anesth. Analg., January 1, 2005; 100(1): 158 - 161.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2004 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2004 by the International Anesthesia Research Society.