JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsui, B. C. H.
Right arrow Articles by Seal, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsui, B. C. H.
Right arrow Articles by Seal, R.
Related Collections
Right arrow Pediatrics
Right arrow Regional Anesthesia

Anesth Analg 2004;99:694-696
© 2004 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000130617.79600.05


PEDIATRIC ANESTHESIA

Threshold Current for an Insulated Epidural Needle in Pediatric Patients

Ban C. H. Tsui, MD MSc, FRCPC, Alese Wagner, BSc, Dominic Cave, MBBS FRCPC, and Rob Seal, MD FRCPC

Department of Anesthesiology and Pain Medicine, University of Alberta, Edmonton, Alberta, Canada

Address correspondence and reprint requests to Ban C. H. Tsui, MSC, MD, FRCP(C), Department of Anesthesiology and Pain Medicine, University of Alberta Hospitals, 3B2.32 Walter Mackenzie Health Science Centre, 8440-112 St., Edmonton, Alberta, Canada T6G 2B7. Address e-mail to btsui{at}ualberta.ca

We designed this study to determine the threshold current for nerve stimulation of an insulated needle in the epidural space. The intended dermatome was identified using the bony landmarks of the spine. An 18-gauge insulated Tuohy needle was inserted perpendicularly to the skin and advanced until "loss of resistance" was felt. A nerve stimulator was then connected to the insulated needle. Twenty patients were studied using an insulated Tuohy needle and one patient was studied using a noninsulated Tuohy needle. Muscle twitch was elicited with a current of 11.1 ± 3.1 mA (mean ± SD) in all patients in which an insulated needle was used. Muscle twitches were within 2 myotomes of the intended level (based on bony landmarks). Muscle twitch was not elicited with a noninsulated needle. After catheter threading, positive stimulation tests were elicited via epidural catheters in all patients (4.9 ± 2.3 mA). Postoperative radiograph confirmed all catheter placements within 2 myotomes of the muscle twitches. Electrical stimulation may be a useful adjuvant tool to loss of resistance for confirming proper thoracic epidural needle placement. The threshold current criteria for an insulated needle (6–17 mA) would be higher than the original Tsui test criteria described for an epidural catheter (1–10 mA) in the epidural space.

IMPLICATIONS: Electrical stimulation may be a useful adjuvant tool for confirming proper thoracic epidural needle placement. The threshold current for an insulated needle is higher than the original Tsui test criteria described for an epidural catheter in the epidural space.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
B. C. H. Tsui
Epidural stimulation test criteria.
Anesth. Analg., September 1, 2006; 103(3): 775 - 776.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. Y. Chan, J. C. De La Cuadra Fontaine, J. Doan, and D. Q. Tran
Stimulating cervical epidural catheter.
Anesth. Analg., June 1, 2006; 102(6): 1910 - 1910.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C. H. Tsui
Is It Time to Perform All Thoracic Epidural Placements Under Fluoroscopy?
Anesth. Analg., May 1, 2006; 102(5): 1586 - 1586.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
B. C.H. Tsui
Verifying spinal needle location in the presence of a "dry tap".
Can J Anesth, April 1, 2006; 53(4): 424 - 425.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C. H. Tsui, D. Emery, R. R. E. Uwiera, and B. Finucane
The Use of Electrical Stimulation to Monitor Epidural Needle Advancement in a Porcine Model
Anesth. Analg., June 1, 2005; 100(6): 1611 - 1613.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. C.H. Tsui, A. M. Wagner, K. Cunningham, S. Perry, S. Desai, and R. Seal
Threshold Current of an Insulated Needle in the Intrathecal Space in Pediatric Patients
Anesth. Analg., March 1, 2005; 100(3): 662 - 665.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2004 by the International Anesthesia Research Society.