CARDIOVASCULAR ANESTHESIA
Optimal Head Rotation for Internal Jugular Vein Cannulation When Relying on External Landmarks
Jeremy A. Lieberman, MD,
Kayode A. Williams, MD, and
Andrew L. Rosenberg, MD
Department of Anesthesiology and Critical Care Medicine, University of Michigan Medical Center, Ann Arbor, Michigan
Address correspondence to Andrew L. Rosenberg, MD, Department of Anesthesiology, University of Michigan Medical Center, Room 1G323 UH, Box 0048, Ann Arbor, MI. Address e-mail to jliberma{at}umich.edu
External anatomic landmarks have traditionally been used to approximate the location of the neck blood vessels to optimize central venous cannulation of the internal jugular vein (IJV) while avoiding the common carotid artery (CCA). Head rotation affects vessel orientation, but most landmark techniques do not specify its optimal degree. We simulated catheter insertion via both an anterior and central approach to the right IJV using an ultrasound probe held in the manner of a syringe and needle in 49 volunteers. Increased head rotation from 0°, 15°, 30°, 45°, and 60° to the left of midline was associated with higher probability of a simulated needle contacting the IJV and the CCA. For both approaches, the risk of CCA contact was <10% for head rotations of 45°. Increased body surface area (BSA) and body mass index (BMI) were associated with more CCA contact at head rotations of 45° or 60°. To optimize IJV contact while reducing the likelihood of inadvertent contact with the CCA, the head should be rotated no more than 30° in patients with high BMI or BSA, but it may be turned to 60° if BMI or BSA is low.
IMPLICATIONS: In a study of 49 volunteers, an ultrasound probe held in the manner of a syringe and needle demonstrated that the optimal head rotation to maximize internal jugular vein cannulation and minimize carotid artery puncture was 30° from midline for obese patients and as much as 60° for non-obese patients.
This article has been cited by other articles:

|
 |

|
 |
 
W S Flournoy and S Mani
Percutaneous external jugular vein catheterization in piglets using a triangulation technique
Lab Anim,
October 1, 2009;
43(4):
344 - 349.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Feller-Kopman
Ultrasound-Guided Internal Jugular Access: A Proposed Standardized Approach and Implications for Training and Practice
Chest,
July 1, 2007;
132(1):
302 - 309.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. E. Arthur, M. R. Castresana, J. W. Paschal, and V. S. Patel
Acute Cerebellar Stroke After Inadvertent Cannulation and Pulmonary Artery Catheter Placement in the Right Vertebral Artery
Anesth. Analg.,
December 1, 2006;
103(6):
1625 - 1626.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. L. Bailey, E. E. Whitaker, L. S. Palmer, and L. G. Glance
The accuracy of the central landmark used for central venous catheterization of the internal jugular vein.
Anesth. Analg.,
May 1, 2006;
102(5):
1327 - 1332.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Z. Jankovic, A. Boon, and R. Prasad
Fatal haemothorax following large-bore percutaneous cannulation before liver transplantation
Br. J. Anaesth.,
October 1, 2005;
95(4):
472 - 476.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|