JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lieberman, J. A.
Right arrow Articles by Rosenberg, A. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lieberman, J. A.
Right arrow Articles by Rosenberg, A. L.
Related Collections
Right arrow Anesthetic Techniques
Right arrow Monitoring (Cardiac)

Anesth Analg 2004;99:982-988
© 2004 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000132908.77111.CA


CARDIOVASCULAR ANESTHESIA

Optimal Head Rotation for Internal Jugular Vein Cannulation When Relying on External Landmarks

Jeremy A. Lieberman, MD, Kayode A. Williams, MD, and Andrew L. Rosenberg, MD

Department of Anesthesiology and Critical Care Medicine, University of Michigan Medical Center, Ann Arbor, Michigan

Address correspondence to Andrew L. Rosenberg, MD, Department of Anesthesiology, University of Michigan Medical Center, Room 1G323 UH, Box 0048, Ann Arbor, MI. Address e-mail to jliberma{at}umich.edu

External anatomic landmarks have traditionally been used to approximate the location of the neck blood vessels to optimize central venous cannulation of the internal jugular vein (IJV) while avoiding the common carotid artery (CCA). Head rotation affects vessel orientation, but most landmark techniques do not specify its optimal degree. We simulated catheter insertion via both an anterior and central approach to the right IJV using an ultrasound probe held in the manner of a syringe and needle in 49 volunteers. Increased head rotation from 0°, 15°, 30°, 45°, and 60° to the left of midline was associated with higher probability of a simulated needle contacting the IJV and the CCA. For both approaches, the risk of CCA contact was <10% for head rotations of ≤45°. Increased body surface area (BSA) and body mass index (BMI) were associated with more CCA contact at head rotations of 45° or 60°. To optimize IJV contact while reducing the likelihood of inadvertent contact with the CCA, the head should be rotated no more than 30° in patients with high BMI or BSA, but it may be turned to 60° if BMI or BSA is low.

IMPLICATIONS: In a study of 49 volunteers, an ultrasound probe held in the manner of a syringe and needle demonstrated that the optimal head rotation to maximize internal jugular vein cannulation and minimize carotid artery puncture was 30° from midline for obese patients and as much as 60° for non-obese patients.




This article has been cited by other articles:


Home page
Lab AnimHome page
W S Flournoy and S Mani
Percutaneous external jugular vein catheterization in piglets using a triangulation technique
Lab Anim, October 1, 2009; 43(4): 344 - 349.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. Feller-Kopman
Ultrasound-Guided Internal Jugular Access: A Proposed Standardized Approach and Implications for Training and Practice
Chest, July 1, 2007; 132(1): 302 - 309.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. E. Arthur, M. R. Castresana, J. W. Paschal, and V. S. Patel
Acute Cerebellar Stroke After Inadvertent Cannulation and Pulmonary Artery Catheter Placement in the Right Vertebral Artery
Anesth. Analg., December 1, 2006; 103(6): 1625 - 1626.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. L. Bailey, E. E. Whitaker, L. S. Palmer, and L. G. Glance
The accuracy of the central landmark used for central venous catheterization of the internal jugular vein.
Anesth. Analg., May 1, 2006; 102(5): 1327 - 1332.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
Z. Jankovic, A. Boon, and R. Prasad
Fatal haemothorax following large-bore percutaneous cannulation before liver transplantation
Br. J. Anaesth., October 1, 2005; 95(4): 472 - 476.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
Minerva
BMJ, December 11, 2004; 329(7479): E335 - E335.
[Full Text] [PDF]


Home page
BMJHome page
Minerva
BMJ, October 2, 2004; 329(7469): 808 - 808.
[Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2004 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2004 by the International Anesthesia Research Society.