JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by White, P. F.
Right arrow Articles by Kariger, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by White, P. F.
Right arrow Articles by Kariger, R.
Related Collections
Right arrow Monitoring (Non-cardiac)
Right arrow Pharmacology

Anesth Analg 2004;99:1429-1435
© 2004 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000132784.57622.CC


TECHNOLOGY, COMPUTING, AND SIMULATION

Is the Patient State Analyzer with the PSArray2 a Cost-Effective Alternative to the Bispectral Index Monitor During the Perioperative Period?

Paul F. White, PhD MD, FANZCA*, Jun Tang, MD*, Hong Ma, MD*, Ronald H. Wender, MD{dagger}, Alexander Sloninsky, MD{dagger}, and Robert Kariger, MD{dagger}

*Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center, Dallas, Texas; and {dagger}Department of Anesthesiology, Cedars-Sinai Medical Center, Los Angeles, California

Address correspondence and reprint requests to Paul F. White, PhD, MD, FANZCA, Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center at Dallas, 5323 Harry Hines Blvd., F2.208, Dallas, TX 75390-9068. Address e-mail to paul.white{at}utsouthwestern.edu

New disposable electrodes, the PSArrayTM2 and XP sensorTM, have been developed for the patient state analyzer (PSA) and the bispectral index (BIS) monitors, respectively. We designed this clinical study to compare the sensitivity and specificity of the patient state index (PSI) with the BIS during the perioperative period when the new electrode sensors were used. Twenty-two consenting patients scheduled for elective laparoscopic procedures were enrolled in this prospective study. The elapsed time to apply electrodes and obtain a baseline index value was recorded, as were the comparative PSI and BIS values at specific time intervals during the induction, maintenance, and emergence periods in patients who were administered a standardized general anesthetic. In addition, the changes in these indices were recorded after a bolus dose of propofol (20 mg IV) or a 2% increase or decrease in the inspired concentration of desflurane during the maintenance period. The total elapsed time to obtain an index value was similar with both devices (66 ± 32 s versus 72 ± 41 s for the PSA and BIS, respectively). By using logistic regression models, both the BIS and PSI were found to be equally effective as predictors of unconsciousness (i.e., failure to respond to verbal stimuli). The PSI also correlated with the BIS during both the induction of (R = 0.85) and the emergence from (R = 0.74) general anesthesia. The area under the receiver operating characteristic curve for detection of consciousness also indicated a similar performance with the PSI (0.98 ± 0.05) and the BIS (0.97 ± 0.05). During the maintenance period, the PSI values tended to be lower than the BIS value; however, the responses to changes in propofol and desflurane were similar. Finally, the PSI (versus BIS) values showed less interference from the electrocautery unit during the operation (31% versus 73%, respectively). Although the list price of the PSArray2 disposable electrode strip ($24.95) was higher than that of the BIS XP sensor ($17.50), the average sale price ($14.95) was identical for both electrode systems. Therefore, we conclude that the PSA monitor with the PSArray2 is a cost-effective alternative to the BIS monitor with the XP sensor for evaluating consciousness during the induction of and emergence from general anesthesia, as well as for titrating propofol and desflurane during the maintenance period.

IMPLICATIONS: The new disposable electrode configuration, PSArray2, for the patient state analyzer would appear to be a cost-effective alternative to the electroencephalogram-based bispectral index monitor for assessing the level of consciousness during the induction of and emergence from anesthesia, as well as for titrating intravenous (propofol) and volatile (desflurane) anesthetics during the maintenance period.




This article has been cited by other articles:


Home page
Mayo Clin Proc.Home page
C. J. Chisholm, J. Zurica, D. Mironov, R. R. Sciacca, E. Ornstein, and E. J. Heyer
Comparison of Electrophysiologic Monitors With Clinical Assessment of Level of Sedation
Mayo Clin. Proc., January 1, 2006; 81(1): 46 - 52.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
P. F. White, J. Tang, G. F. Romero, R. H. Wender, R. Naruse, A. Sloninsky, and R. Kariger
A Comparison of State and Response Entropy Versus Bispectral Index Values During the Perioperative Period
Anesth. Analg., January 1, 2006; 102(1): 160 - 167.
[Abstract] [Full Text] [PDF]




Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2004 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press