JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (Publish Ahead of Print[PDF])
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Masui, K.
Right arrow Articles by Struys, M. M. R. F.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Masui, K.
Right arrow Articles by Struys, M. M. R. F.

Anesth Analg 2009;0:ANE.0b013e3181bdcf5b
© 2009 International Anesthesia Research Society
doi: 10.1213/ANE.0b013e3181bdcf5b

The Performance of Compartmental and Physiologically Based Recirculatory Pharmacokinetic Models for Propofol: A Comparison Using Bolus, Continuous, and Target-Controlled Infusion Data

Kenichi Masui, MD, PhD*,{dagger}, Richard N. Upton, BSc, PhD{ddagger}, Anthony G. Doufas, MD, PhD§, Johan F. Coetzee, BSc, MB, ChB, MMed(Anes.), FCA(SA), Dip.Dat., PhD||, Tomiei Kazama, MD, PhD*, Eric P. Mortier, MD, DSc{dagger}, and Michel M. R. F. Struys, MD, PhD,{dagger}

From the *Department of Anesthesiology, National Defense Medical College, Tokorozawa, Japan; {dagger}Department of Anesthesia, Ghent University, Gent, Belgium; {ddagger}Department of Anaesthesia and Intensive Care, Royal Adelaide Hospital, University of Adelaide, Adelaide, Australia; §Department of Anesthesiology, Stanford University School of Medicine, Stanford, California; ||Department of Anesthesiology and Critical Care, Stellenbosch University Faculty of Health Sciences, Republic of South Africa; and ¶Department of Anesthesia, University Medical Center Groningen, Groningen, University of Groningen, The Netherlands.

Address correspondence to Michel M.R.F Struys, MD, PhD, Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands. Address e-mail to m.m.r.f.struys{at}anest.umcg.nl.

Abstract

Background: With the growing use of pharmacokinetic (PK)-driven drug delivery and/or drug advisory displays, identifying the PK model that best characterizes propofol plasma concentration (Cp) across a variety of dosing conditions would be useful. We tested the accuracy of 3 compartmental models and 1 physiologically based recirculatory PK model for propofol to predict the time course of propofol Cp using concentration-time data originated from studies that used different infusion schemes.

Methods: Three compartmental PK models for propofol, called the "Marsh," the "Schnider," and the "Schüttler" models, and 1 physiologically based recirculatory model called the "Upton" model, were used to simulate the time course of propofol Cp. To test the accuracy of the models, we used published measured plasma concentration data that originated from studies of manual (bolus and short infusion) and computer-controlled (target-controlled infusion [TCI] and long infusion) propofol dosing schemes. Measured/predicted (M/P) propofol Cp plots were constructed for each dataset. Bias and inaccuracy of each model were assessed by median prediction error (MDPE) and median absolute prediction error (MDAPE), respectively.

Results: The M/P propofol Cp in the 4 PK models revealed bias in all 3 compartmental models during the bolus and short infusion regimens. In the long infusion, a worse M/P propofol Cp at higher concentration was seen for the Marsh and the Schüttler models than for the 2 other models. Less biased M/P propofol Cp was found for all models during TCI. In the bolus group, after 1 min, a clear overprediction was seen for all 3 compartmental models for the entire 5 min; however, this initial error resolved after 4 min in the Schnider model. The Upton model did not predict propofol Cp accurately (major overprediction) during the first minute. During the bolus and short infusion, the Marsh model demonstrated worse MDPE and MDAPE compared with the 3 other models. During short infusion, MDAPE for the Schnider and Schüttler models was better than the Upton and the Marsh models. All models showed similar MDPE and MDAPE during TCI simulations. During long infusion, the Marsh and the Schüttler models underestimated the higher plasma concentrations.

Conclusion: When combining the performance during various infusion regimens, it seems that the Schnider model, although still not perfect, is the recommended model to be used for TCI and advisory displays.







Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2009 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press
Copyright © 2009 by the International Anesthesia Research Society.