JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jahr, J. S.
Right arrow Articles by Driessen, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jahr, J. S.
Right arrow Articles by Driessen, B.

Anesth Analg 2005;100:431-436
© 2005 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000142116.42938.82


TECHNOLOGY, COMPUTING, AND SIMULATION

Lactate Measurement Interference by Hemoglobin-Based Oxygen Carriers (Oxyglobin®, Hemopure®, and HemolinkTM)

Jonathan S. Jahr, MD, Stephen Osgood, MD, Stephen J. Rothenberg, PhD, Qiao-Ling Li, MD, PhD, Anthony W. Butch, PhD, Robert Gunther, PhD, Anthony Cheung, PhD, and Bernd Driessen, DVM, PhD

Departments of Anesthesiology and Pathology and Laboratory Medicine, David Geffen School of Medicine at UCLA, Los Angeles, California, and Department of Anesthesiology, Charles R. Drew University of Medicine and Science, Martin Luther King, Jr./Drew Medical Center, Los Angeles, California; Johns Hopkins University School of Medicine, Baltimore, Maryland; National Institute of Public Health, Cuernavaca, Mexico; Departments of Surgery and Medical Pathology, UC Davis School of Medicine; and Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, Pennsylvania

Address correspondence and reprint requests to Jonathan S. Jahr, MD, Department of Anesthesiology, David Geffen School of Medicine at UCLA, PO Box 951778, Los Angeles, CA, 90095-1778. Address e-mail to jsjahr{at}mednet.ucla.edu.


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 References
 
We sought to determine whether hemoglobin-based oxygen carriers (HBOCs), hemoglobin glutamer-200 [bovine] (HBOC-200, Oxyglobin®), hemoglobin glutamer-250 [bovine] (HBOC-201, Hemopure®), and hemoglobin raffimer (HemolinkTM) interfere with the accuracy of lactate measurements. Combinations of concentrated L-lactate solution, HBOC, and blood or plasma with added PlasmaLyte-ATM were added to sample tubes to make a linear and constant increase in lactate concentration in consecutive samples. Sample lactate concentrations ranged from 5–110 mg/dL (0.6–12 mm) (physiological reference range: 5–20 mg/dL [0.56–2.2 mm]). Comparisons were made between machine measured lactate concentrations and calculated lactate concentrations. For Hb glutamer-250, the average difference between measured and calculated lactate concentrations was –5.1 mg/dL (–0.57 mm) (LX-20®), with greater underestimation at larger lactate concentrations. For Hb raffimer, the average difference was –2.2 mg/dL (–0.24 mm) (LX-20®). The veterinary product, Hb glutamer-200, was tested on 3 analyzers (LX-20®, YSI 1500, and YSI 2300). The YSI 1500 was the most accurate instrument with the mean difference between measured minus calculated lactate being +1.3 mg/dL versus –2.6 mg/dL (YSI 2300) and –8.4 mg/dL (LX-20®). The clinical implications of this study are that with increasing levels of an HBOC in plasma, lactate interpretation may become inaccurate, especially at larger lactate concentrations, causing underestimation of measured lactate values and possible under-treatment of the patient. Therefore, caution must be exercised when interpreting lactate results when a HBOC is present in plasma.


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 References
 
Hemoglobin-based oxygen carriers (HBOCs) are solutions of cell-free hemoglobin (Hb) that have been developed for treatment of anemia or resuscitation from hemorrhagic shock. They combine oxygen transport with volume-expanding properties and thus may be ideal candidates for resuscitation, superior to traditional plasma expanders (e.g., hydroxyethyl starch solutions) (1–8). The HBOCs used in this study, hemoglobin glutamer-200 [bovine] (HBOC-200, Oxyglobin®), hemoglobin glutamer-250 [bovine] (HBOC-201, Hemopure®; Biopure Corporation, Cambridge, MA), and hemoglobin raffimer (HemolinkTM; Hemosol Inc., Toronto, ON), have not been tested for interference with lactate measurements (9–15). We hypothesized that these three blood substitutes may interfere with the accuracy of lactate determination. It should be noted that the University of California Los Angeles (UCLA) Clinical Laboratory reference ranges of plasma lactate are 5–20 mg/dL (0.56–2.2 mm).

We further hypothesized that one of the reasons for underestimation of accurate lactate levels in the lactate analyzers may be scavenging of hydrogen peroxide, an intermediary, by the cell-free HBOC molecules in the sample. In fact, all Hbs, including modified Hbs in particular, have more of a propensity to react in an enzymatic fashion with peroxide than unmodified Hbs (16–19). Because the analyzers use hydrogen peroxide as a means to detect lactate concentration, this process could be interfered with by HBOCs.

The lactate measurements were made by three clinical lactate analyzers (Synchron LX-20®, Beckman Coulter, Fullerton, CA; YSI 1500 SPORT and YSI 2300 STAT; YSI Inc., Yellow Springs, OH) in combination with three HBOCs, one approved veterinary product (Hb glutamer-200) and two experimental human therapeutics (Hb glutamer-250 and Hb raffimer).


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 References
 
To study three lactate analyzers and three HBOCs, a series of experiments were performed: 1) validating the veterinary HBOC (Hb glutamer-200) with the analyzers used for our published veterinary shock and resuscitation experiments (6–8), the YSI 1500 and YSI 2300 with bovine blood, 2) testing the HBOCs undergoing human trials (Hb glutamer-250 and Hb raffimer) with a currently used clinical lactate analyzer, LX-20®, with human plasma diluted in Plasma-Lyte ATM (Baxter, Deerfield, IL), and 3) an external validation of the LX-20® without HBOCs at clinically increased concentrations of lactate. Despite performing an external validation series on the LX-20® at a wider range of lactate concentrations, all three analyzers continually self-calibrate for lactate in either blood or plasma accurately during routine use.

The correlation between machine-measured lactate and calculated lactate concentrations was studied, testing for interference by HBOCs. Because HBOCs themselves contain lactate in their initial preparation, the calculated final lactate concentration in each test sample was the sum of baseline lactate in human plasma or bovine blood, lactate contained in the HBOC solution itself, and lactate added to the test sample from a known concentrated stock solution.

This series of experiments was conducted at our laboratories at the University of California (UC) Davis using the YSI 1500 and 2300 lactate analyzers. The YSI 1500 and 2300 instruments report lactate concentrations in mm; however we converted all data to mg/dL (mg/dL is the unit clinically reported at UCLA and recorded by the LX-20®). The conversion factor between units for lactic acid is 1.00 mg/dL = 0.111 mm (MW lactic acid = 90.079 Daltons). Lithium L-lactate (Sigma, St. Louis, MO) was dissolved in Plasma-Lyte ATM, a lactate-free, balanced salt solution. From this concentrated stock lactate solution, specific amounts were added to 5 identical sample sets to create a linear and constant increase in lactate concentration in consecutive samples. Final lactate concentrations ranged from 5 to 70 mg/dL. Bovine whole blood was collected from a healthy live animal (these were remainder samples of collected bovine blood for other experiments, not requiring veterinary institutional approval at UC Davis), in gray-top tubes (Becton Dickinson, Franklin Lakes, NJ) and aliquots were added to each of the samples (therefore, a veterinary HBOC was matched with blood from an animal source). Finally, Hb glutamer-200 was added to make each sample set have a different final HBOC concentration (0.13, 1.3, 2.6, 3.6, and 5 mg/dL), with each set still having the identical range of lactate concentrations. We wanted to test to whether larger concentrations of HBOC had a greater interference effect. The final sample volume was 1.5 mL. Single measurements for each sample were performed on both YSI instruments.

IRB exemption at UCLA for the use of remainder sample human plasma for routine lactate concentration measurements was obtained. Discard human plasma samples from the clinical laboratory were pooled (human plasma was donated by the Chemistry Laboratory at UCLA from non-expired lactate samples in gray top tubes). We studied all 3 HBOCs on the LX-20®: Hb glutamer-200, Hb-250 (0.13, 1.3, 2.6, 3.9, and 6.5 g/dL), and Hb raffimer (0.1, 1, 2, 3, and 5 g/dL). Five sample sets were made for each HBOC at the above concentrations in a similar manner as for the YSI series. The difference being the use of human plasma instead of bovine blood (we wanted to match products intended for human use with human plasma) and a slightly larger lactate concentration range. Final calculated lactate concentrations ranged from 10 to 110 mg/dL. Single measurements were performed on the LX-20®.

Lithium L-lactate was dissolved in saline and added to a human plasma pool, obtained from the UCLA Medical Center Clinical Laboratory. Dilutions were made to yield target lactate concentrations of 20, 40, 60, 80, and 100 mg/dL (designed to fit high normal and increased plasma lactate concentrations, the same dilutions used by the UCLA clinical laboratory for periodic validation of their analyzers). Each sample was analyzed in triplicate on the LX® 20 analyzer (see Table 2). This external validation was only designed for the LX-20®, as this is the only clinically used analyzer at UCLA. This additional series was presented to sample wider ranges of lactate without HBOCs present to determine if simply high lactate levels would cause the analyzer to become inaccurate, as the internal automatic calibration on this analyzer does not test at such large lactate concentrations.


View this table:
[in this window]
[in a new window]
 
Table 2. Accuracy of Synchron LX-20® analyzer when testing human plasma samples containing added lactate but no hemoglobin-based oxygen carrier

 

The differences between measured (Y)-minus-calculated (X) lactate were quantified by the mean difference and by the root mean square error (RMSE) defined as RMSE = {surd} ([mean of calculated minus measured difference]2 + [standard deviation of the differences]2)]. The RMSE incorporates both the bias and the variability about the mean difference and therefore indicates the total variability about zero (20). Bland-Altman plots of measured-minus-calculated differences (Y–X, vertical axis) versus the mean of the measured-and-calculated value ((Y+X)/2, horizontal axis) are provided (21,22) with a linear regression analysis added to the plot highlight measurement bias. Correlations between Y versus X (corresponding to the linear regression of X on Y) and the correlations between (Y–X) versus (Y+X)/2 (Bland-Altman correlation) are also reported. If the latter correlation is zero, then there is no trend in the Y–X difference (the bias) with increasing or decreasing lactate magnitude.


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 References
 
The mean difference between measured-minus-calculated lactate for Hb glutamer-200 was +1.3 mg/dL (YSI 1500) (3.4% of the overall mean of measured-and-calculated lactate) and –2.6 mg/dL (YSI 2300) (7.2% of overall mean) (Fig. 1A&B and Table 3). The data points are not differentiated by HBOC concentration, as we did not observe any HBOC–concentration-dependent effects on interference. The RMSE for Hb glutamer-200 is 3.3 mg/dL (YSI 1500) (8.7% of the overall mean) and 3.8 mg/dL (YSI 2300) (10.6% of the overall mean). The Bland-Altman correlation (r) between the measured-minus-calculated difference versus the average of the measured-plus-calculated is r = 0.165 (P = 0.49) (YSI 1500) and r = –0.424 (P = 0.07) (YSI 2300). Adding Hb glutamer-200 resulted in a systematic trend in the difference between measured-minus-calculated lactate for the YSI 2300 but not for the YSI 1500. If there were perfect agreement between measured-and-calculated lactate values, the Bland-Altman correlation would be zero.



View larger version (27K):
[in this window]
[in a new window]
 
Figure 1. Lactate interference by hemoglobin-based oxygen carriers. Bland-Altman plots with linear regression lines for samples containing added lactate, Plasma-Lyte ATM, and hemoglobin glutamer-200, hemoglobin glutamer-250, or hemoglobin raffimer oxygen carriers tested on YSI 1500 SPORT, YSI 2300 STAT, and Synchron LX-20® lactate analyzers. A. YSI 1500 with hemoglobin glutamer-200. B. YSI 2300 with hemoglobin glutamer-200. C. LX-20® with hemoglobin glutamer-200. D. LX-20® with hemoglobin glutamer-250. E. LX-20® with hemoglobin raffimer.

 

View this table:
[in this window]
[in a new window]
 
Table 3. Summary Statistics for Measured (Y) Versus Calculated (X) Lactate

 

The mean difference between measured-minus-calculated lactate for Hb glutamer-200 was –8.4 mg/dL (LX-20®) (13.4% of the overall mean); for Hb glutamer-250 it was –5.1 mg/dL (LX-20®) (11.8% of the overall mean), and for Hb raffimer it was –2.2 mg/dL (LX-20®) (3.7% of overall mean) (Fig. 1C–E and Table 3). Note that data points are not differentiated by HBOC concentration, as there were no significant differences among the different groups. Hb glutamer-200 and Hb glutamer-250 have greater bias than Hb raffimer with measured values systematically less than calculated values, especially at larger lactate concentrations. The RMSE for Hb glutamer-200 was 11.0 mg/dL (LX-20®) (17.6% of the overall mean); for Hb glutamer-250 it was 6.4 mg/dL (LX-20®) (14.9% of the overall mean), and for Hb raffimer it was 4.6 mg/dL (LX-20®) (8.0% of the overall mean). These findings show that Hb glutamer-200 and Hb glutamer-250 cause the LX-20® to consistently underestimate calculated lactates with a larger error at larger concentrations. The difference between measured-minus-calculated lactate varies systematically, not randomly, for Hb glutamer-200 and Hb glutamer-250 but not for Hb raffimer. For Hb raffimer, the Bland-Altman correlation was r = 0.106 (P = 0.67) (LX-20®), indicating no significant trend in the differences. However, for Hb glutamer-200 and Hb glutamer-250, the Bland-Altman correlation was r = –0.742 (P < 0.001) (LX-20®) and r = –0.891 (P < 0.001) (LX-20®), respectively.

For the LX® 20 analyzer measuring the control (no HBOC) samples, the Bland-Altman concordance coefficient (r) was nearly zero, and the mean difference in the Bland-Altman analysis was <1 mg/dL lactate, indicating that the LX-20® was accurate in the absence of HBOC.


    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 References
 
HBOCs are purified solutions of highly polymerized bovine or human Hb. Hb glutamer-200 is Food and Drug Administration (FDA) approved for clinical use in canine anemia (1) and is closely related to Hb glutamer-250 (Table 1), which is approved for human use in South Africa and is currently under FDA review in the United States (US). Hb raffimer has also received FDA clearance for preliminary testing in the US.


View this table:
[in this window]
[in a new window]
 
Table 1. Physical and chemical properties of hemoglobin glutamer-200, hemoglobin glutamer-250, and hemoglobin raffimer

 

When we compared the performance of the LX-20® lactate analyzer in samples containing no HBOC (external validation series), the following was notable: the control data (Table 2) demonstrate that the LX-20® instrument, per se, provides very accurate measurements over a wide range of lactate concentrations.

In samples analyzed on the LX-20® containing the human HBOC, Hb glutamer-250, in concentrations comparable to plasma Hb levels likely to be achieved under clinical conditions of HBOC infusion (approximately 1–2 g/dL), the average difference between measured and calculated lactate concentrations was –5.1 mg/dL (–0.57 mm), with greater underestimation at larger lactate concentrations. In fact, the difference between measured and calculated lactate at a lactate concentration of 75 mg/dL was –12 mg/dL (–1.3 mm). It is important to stress that this discrepancy is clinically important, given the normal reference range for plasma lactate. The average measured-minus-calculated lactate discrepancy represents 33% of the normal physiological lactate reference range. When Hb raffimer is present in plasma being analyzed by the LX-20®, the average difference is –2.2 mg/dL [–0.24 mm] or 14% of the reference range.

The veterinary product, Hb glutamer-200, was tested on all three analyzers. The YSI 1500 proved to be the most accurate instrument, with the mean difference between measured-minus-calculated lactate being +1.3 mg/dL (the only series in which lactate was overestimated) versus –2.8 mg/dL (YSI 2300) and –8.4 mg/dL (LX-20®). Therefore, the YSI 1500 instrument was used to obtain the most accurate measurement of baseline lactate levels in the three HBOC stock preparations used in this study (Table 1).

In both the YSI and LX-20® analyzers, lactate is bound by a substrate specific enzyme, lactate oxidase, which oxidizes lactate producing hydrogen peroxide. In the YSI analyzers, the hydrogen peroxide passes through a cellulose acetate layer to a platinum electrode where the hydrogen peroxide is oxidized. The resulting current is proportional to the concentration of the lactate. In the LX-20® analyzer, hydrogen peroxide subsequently reacts with dichlorobenzenesulfonic acid and 4-aminoantipyrine to form a colored chromophore that absorbs light at 520 nm; the change in absorbance is proportional to the concentration of lactate in a given sample.

Hydrogen peroxide reacts rapidly with the ferrous (HbFe2+) and ferric heme (HbFe3+) moieties of HBOCs (16). In fact, in the presence of excess H2O2, hypervalent ferryl heme (HbFe4+) can be formed. HBOCs contain Hb outside its protective environment created by the red blood cell membrane; hence, unhindered oxidation of its iron center occurs (16). If enough H2O2 is being consumed by this oxidation process, these lactate analyzers will underestimate the actual lactate concentration of the sample. At higher lactate levels we observed greater underestimation of calculated lactate (Fig. 1), presumably as a result of increased generation and consequently increased scavenging of hydrogen peroxide by HBOC molecules. We did not observe HBOC concentration-dependent interference; thus, it is likely that there was adequate HBOC present, even at the smallest concentrations we tested, to cause interference.

Other possible mechanisms of interference in spectrophotometric analyzers by HBOCs have been proposed, including light scattering by HBOC aggregates or particles and altered optical absorbance by the molecular alterations to Hb in HBOCs (13).

Based on the samples tested in this study, our results indicate that calculated lactate levels in the presence of HBOCs are underestimated most of the time when measured by a lactate analyzer. The clinical implications of this study are that with increasing levels of a HBOC in plasma, lactate interpretation may become inaccurate, especially at larger lactate concentrations, causing underestimation of measured lactate values and possible under-treatment of the patient. Therefore, caution must be exercised when interpreting lactate results when a HBOC is present in plasma.

We thank Jeffrey Gornbein, Dr. PH, UCLA Department of Biomathematics, for his statistical support and Jessica Tsukamoto for her technical assistance in the experiments. The authors thank Biopure Corp. and Hemosol Inc. for donating Hemopure® and HemolinkTM for study in our laboratories. Oxyglobin® was purchased at a veterinary pharmacy. We also thank Drs. Egil Steien and Vatche Bezdikian for their valuable assistance in the design and implementation of the study.


    Footnotes
 
Supported by institutional funding from UCLA and UC Davis.

Dr. Jahr has served as principal investigator on two Biopure Corp. and two Hemosol Inc. Clinical Phase II and III trials. He is on the Speakers Bureau for both Biopure Corp. and Hemosol Inc.; however, no funding was received from either manufacturer for this study.

Accepted for publication July 27, 2004.


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 References
 

  1. Jahr JS, Nesargi SB, Lewis K, et al. Blood substitutes and oxygen therapeutics: an overview and current status. Am J Ther 2002;9:437–43.[Medline]
  2. Winslow, RM. Current status of blood substitute research: towards a paradigm. J Int Med 2003;253:508–17.[Web of Science][Medline]
  3. Stowell CP. Hemoglobin-based oxygen carriers. Curr Opin Hematol 2002;9:537–43.[Medline]
  4. Standl T. Haemoglobin-based erythrocyte transfusion substitutes. Expert Opin Biol Ther 2001;1:831–43.[Medline]
  5. Winslow RM. Alternative oxygen therapeutics: products, status of clinical trials, and future prospects. Curr Hematol Rep 2003;2:503–10.[Medline]
  6. Cheung ATW, Jahr JS, Driessen B, et al. Effects of a hemoglobin-based oxygen carrier (HBOC, Hemoglobin glutamer-200 [bovine]) on the microcirculation in a canine hypovolemia model: a non-invasive, computer-assisted intravital microscopy study Anesth Analg 2001;93:832–8.[Abstract/Free Full Text]
  7. Driessen B, Jahr JS, Lurie F, et al. Arterial oxygenation and oxygen delivery after hemoglobin-based oxygen carrier infusion in canine hypovolemic shock: a dose-response study. Crit Care Med 2003;31:1771–9.[Medline]
  8. Driessen B, Jahr JS, Lurie F, et al. Effects of hemoglobin-based oxygen carrier Hemoglobin glutamer-200 (bovine) on intestinal perfusion and oxygenation in a canine hypovolemia model. Br J Anaesth 2001;86:683–92.[Abstract/Free Full Text]
  9. Jahr JS, Lurie F, Gosselin R, et al. Effects of hemoglobin glutamer-250 (bovine) (HBOC-201, Hemopure) on coagulation testing. Am J Ther 2002;9:431–6.[Medline]
  10. Wolthuis A, Peek D, Scholten R, et al. Effect of the hemoglobin-based oxygen carrier HBOC-201 on laboratory instrumentation: cobas integra, chiron blood gas analyzer 840, Sysmex SE-9000 and BCT. Clin Chem Lab Med 1999;37:71–6.[Medline]
  11. Callas DD, Clark TL, Moreira PL, et al. In vitro effects of a novel hemoglobin-based oxygen carrier on routine chemistry, therapeutic drug, coagulation, hematology, and blood bank assays. Clin Chem 1997;43:1744–8.[Abstract/Free Full Text]
  12. Ma Z, Monk TG, Goodnough LT, et al. Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests. Clin Chem 1997;43:1732–7.[Abstract/Free Full Text]
  13. Ali AA, Ali GS, Steinke JM, Shepherd AP. Co-oximetry interference by hemoglobin-based blood substitutes. Anesth Analg 2001;92:863–9.[Abstract/Free Full Text]
  14. Chance JJ, Norris EJ, Kroll MH. Mechanism of interference of a polymerized hemoglobin blood substitute in an alkaline phosphatase method. Clin Chem 2000;46:1331–7.[Abstract/Free Full Text]
  15. Kazmierczak SC, Cartrou PG, Best AE, et al. Multiple regression analysis of interference effects from a hemoglobin-based oxygen carrier solution. Clin Chem Lab Med 1999;37:453–64.[Medline]
  16. Yeh LH, Alayash AI. Redox side reactions of haemoglobin and cell signalling mechanisms. J Int Med 2003;253:518–26.[Web of Science][Medline]
  17. Alayash AI. Oxidative mechanisms of hemoglobin-based blood substitutes. Art Cells Blood Subs Immob Biotech 2001;29:415–25.[Medline]
  18. Alayash AI. Hemoglobin-based blood substitutes and the hazards of blood radicals. Free Radic Res 2000;33:341–8.[Web of Science][Medline]
  19. Alayash AI. Hemoglobin-based blood substitutes: oxygen carriers, pressor agents, or oxidants? Nat Biotechnol 1999;17:545–9.[Web of Science][Medline]
  20. Neter J, Wasserman W, Kutner M, eds. Applied linear statistical models, 2nd ed. Homewood: Richard Irwin Inc., 1985: 395–6.
  21. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307–10.[Web of Science][Medline]
  22. Mantha S, Roizen MF, Fleisher LA, et al. Comparing methods of clinical measurement: reporting standards for Bland-Altman analysis. Anesth Analg 2000;90:593–602.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
JAMAHome page
C. Natanson, S. J. Kern, P. Lurie, S. M. Banks, and S. M. Wolfe
Cell-Free Hemoglobin-Based Blood Substitutes and Risk of Myocardial Infarction and Death: A Meta-analysis
JAMA, May 21, 2008; 299(19): 2304 - 2312.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jahr, J. S.
Right arrow Articles by Driessen, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jahr, J. S.
Right arrow Articles by Driessen, B.


Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2005 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press