| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Beat-to-beat assessment of spontaneously occurring fluctuations in heart rate and arterial blood pressure allows noninvasive determination of cardiovagal function, but little is known regarding the effects of general anesthesia on spontaneous baroreflex (SBR) indices. We examined (a) concentration-dependent effects of sevoflurane on SBR indices, heart rate variability (HRV), and blood pressure variability and (b) correlation and agreement between pharmacological baroreflex gains and SBR indices during sevoflurane anesthesia. Continuous electrocardiogram and invasive arterial blood pressure were monitored in nine healthy volunteers before, during, and for 3 h after sevoflurane anesthesia, during which end-tidal sevoflurane was maintained at 0.7%, 1.4%, and 2.0% in random sequences. We derived three SBR indices (sequence method, -index, and low-frequency transfer function) and compared them with pressor and depressor test gains by the pharmacological method. HRV and blood pressure variability were analyzed at a fixed respiratory rate (12 breaths/min) in awake and anesthetized conditions. Except for low-frequency transfer function, SBR indices were depressed by sevoflurane and remained depressed for 30 min after emergence from anesthesia, compared with the conscious baseline value. Spontaneous sequence indices and high- and low-frequency powers of HRV demonstrated concentration-dependent depression. Pharmacological gains and SBR indices during anesthesia generally correlated well, but Bland-Altman analysis revealed that SBR indices had limits of agreement as large as the baroreflex gain itself. These data suggest that spontaneous indices are inadequate estimates of, and are inconsistent with, the pharmacological baroreflex gain during sevoflurane anesthesia.
Arterial baroreflex function is an important short-term regulatory system for maintaining cardiovascular stability and consists of two important limbs, including the sympathetic baroreflex and cardiovagal reflex systems (1,2). Impairment of cardiovagal reflex responses has been associated with some physiological or pathologic conditions, such as aging and hypertension (3,4). More importantly, its clinical application has been highlighted by the increased incidence of cardiac dysrhythmias and decreased survival after myocardial infarction in patients with diminished cardiovagal baroreflex function (5). The first widely used technique to determine baroreflex control of heart rate (HR) was the Oxford method, by which R-R intervals (RRI) were related to increased or decreased arterial blood pressure (BP) by IV injections of vasoactive drugs (6). This simple method, however, has practical limitations, such as a limited number of observations, possible alterations of baroreceptor transduction by vasoactive drugs, artificially induced pressor and depressor transients, and changes in cardiac filling pressure, which may influence the net gain estimate by loading or unloading cardiopulmonary receptors (7). Other investigators have used spontaneous fluctuations of BP and RRI to calculate spontaneous baroreflex (SBR) gains within naturally occurring BP excursions (8). One of the most frequently used spontaneous indices is a sequence method, which uses spontaneous sequences of three or more consecutive beats in which BP progressively increases and RRI progressively lengthens (up-sequence) or in which BP progressively decreases and RRI progressively shortens (down-sequence). For each sequence, the regression between the BP values and the RRI values of the following cardiac cycle is calculated, and the mean of the slopes of the regression lines is regarded as a gain. The spontaneous sequence gain correlates well with that assessed by the drug-induced technique under resting and various experimental conditions, including cardiac autonomic blockade (2,9). Although many studies on baroreflex function have been performed under general anesthesia in both humans and animals, little is known regarding the effects of general anesthesia on SBR indices. Moreover, dose- or concentration-dependent effects of general anesthetics have never been addressed (10,11). Potent volatile anesthetics cause concentration-dependent depressions in pharmacological baroreflex gains and continue to exert depressive effects after emergence from general anesthesia in humans (12,13). Because of the significant correlations between pharmacological gains and SBR indices in conscious humans (2,9), we hypothesized that (a) SBR indices would be similarly depressed in a concentration-dependent manner during, and remain depressed after, general anesthesia with a volatile anesthetic such as sevoflurane and that (b) baroreflex gains by various spontaneous methods would correlate with, and be surrogates for, pharmacological gains during sevoflurane anesthesia. In addition, spectral analyses of HR (HR variability; HRV) and BP (BP variability; BPV) were applied in each session of baroreflex determinations in an attempt to interpret the effects of general anesthesia on autonomic modulations of RRI (14).
Ten healthy, nonsmoking volunteers were recruited. All subjects were free of cardiovascular or autonomic disorders and abstained from caffeine-containing beverages and alcohol for at least 24 h before the study. None of the subjects had taken any regular medication during 1 yr before the study. All procedures were approved by the human research committee of Akita University School of Medicine, and written informed consent was obtained from each subject. All volunteers arrived at the laboratory after a 10-h fast without premedication. They were placed in the supine position, and a 22-gauge IV catheter was inserted, with a local anesthetic, into a peripheral vein for the administration of balanced salt solution containing 5% dextrose at 2 mL · kg1 · h1 throughout the experiment. Fluid temperature was maintained at approximately 30°C. Determinations of BP and RRI were made from a radial arterial catheter and an electrocardiography (ECG) lead of the highest signal/noise ratio (Viridia CMS 2000TM; Hewlett-Packard, Boeblingen, Germany), respectively. All subjects received whole-body forced-air warming to maintain baseline tympanic temperature, which was monitored throughout the study. The ambient temperature was set to 25°C30°C to avoid postanesthesia shivering. Subjects were allowed to rest in the supine position for at least 20 min in a quiet environment before the study.
Baseline determinations of HRV, BPV, and baroreflex gains by the pharmacological and SBR methods were made. Then, general anesthesia was induced with 5% sevoflurane (inspiratory) in air (5 L/min) and oxygen (1 L/min), and a laryngeal mask airway was inserted to secure the airway, without any other adjuvant, including muscle relaxant or opioid. The lungs were mechanically ventilated (tidal volume, 710 mL/kg at a respiratory rate of 12 breaths/min). Anesthesia was maintained with 0.7%, 1.4%, and 2% end-tidal sevoflurane in air and oxygen (fraction of inspired oxygen, 0.34), and end-tidal CO2 tension was maintained at 35 mm Hg throughout the anesthesia period. Breath-by-breath end-tidal sevoflurane concentration and CO2 tension were measured by a gas analyzer (Capnomac Ultima SV; Datex, Helsinki, Finland), which was calibrated before each use. The order of sevoflurane concentration was randomized to avoid any effect of the testing sequence. To ensure anesthetic equilibration, end-tidal sevoflurane concentration was maintained constant at each level for 20 min by frequently adjusting inspiratory sevoflurane concentrations before baroreflex indices, HRV, and BPV were determined. After approximately 3 h of general anesthesia, sevoflurane was discontinued. After confirming the return of adequate spontaneous respiration and responses to verbal commands, the laryngeal mask airway was removed. The subjects breathed supplemental oxygen 2 L/min via a face mask to ensure oxygen saturation To assess pharmacological baroreflex gains and to correlate these with SBR indices, pressor and depressor tests were performed by using IV injections of phenylephrine (150300 µg) and nitroprusside (150300 µg) to increase and decrease systolic BP (SBP) by 1530 mm Hg, respectively. Pressor and depressor tests were performed at conscious baseline and during 0.7% and 2% end-tidal sevoflurane anesthesia. The doses were chosen on the basis of our previous studies with healthy young individuals (13,15). A period of stabilization >10 min between the pressor and depressor tests allowed HR and SBP to return to the pretest values ±5%. All measurements of pharmacological baroreflex gains were made in triplicate and the results were averaged to provide a single data set in each subject. To determine SBR indices, 10-min recordings of RRI and SBP were made. Recordings of ECG and SBP for spectral analyses during the conscious baseline period and on emergence from anesthesia were made while subjects breathed in step with an auditory signal (metronome) at 12 breaths/min. All subjects were trained and familiarized with paced breathing the day before the study. During sevoflurane anesthesia, the respiratory rate was also fixed at 12 breaths/min to avoid confounding effects of respiratory variables on HRV (16). BP and RRI were determined beat by beat, digitized, stored at a sampling rate of 250 Hz in a computer, and subsequently analyzed offline. A custom program developed to process the digitized data with a 16-bit analog-digital converter (AD7120; ATM Communications, Tokyo, Japan) detected R-waves to determine RRI from ECG signals. The recordings were also observed on an oscilloscope during transfer for elimination of nonsinus or artifactual signals. Digital files were thus generated; each column consisted of SBP, diastolic BP, mean BP generated by electronic integration of the arterial wave form, and RRI values for every cardiac cycle. These files were used for calculations of baroreflex gains and for power spectral analyses.
Pharmacological baroreflex gain was determined by least-square regression analysis between SBP and RRI, when each RRI was plotted as a function of the preceding SBP (6,9,13). Three spontaneous indices were obtained: the spontaneous sequence method, the Methods for spectral analyses of HR and BP have been explained previously in detail (19,20). For each study period, a time series of 512 consecutive RRI and SBP data free of artifacts were selected. A fast Fourier transformation was applied to the tachogram to calculate the amplitude of variations of RRI and SBP as a function of frequency (power spectral density: RRI and SBP powers [units of milliseconds squared and millimeters of mercury squared, respectively] as a function of frequency [hertz]). The RRI and SBP powers were the integrated area under the power spectral density plots as an index of the frequency-specific degree of RRI and SBP variability. Spectral power was determined over the LF (0.040.15 Hz) and HF (0.150.4 Hz) ranges. The LF/HF ratio was calculated for HRV (21). All the statistical analyses were performed by an investigator blinded to the treatment of subjects. Power analysis based on previous baroreflex studies revealed that at least 9 subjects would provide a power more than 0.8 (P = 0.05) for a 40% difference in temporal changes in baroreflex gains (13,15). Hemodynamic and baroreflex data were first analyzed by one-way analysis of variance for repeated measurements. If a significant difference was detected with respect to time, this was followed by a paired Students t-test with Bonferronis correction as a post hoc test to compare hemodynamic and baroreflex data with baseline values and between sessions. Log transformation was used before performing one-way analysis of variance if data were not distributed normally, such as HF and LF power. Correlations and agreements between pharmacological and SBR indices were analyzed by Pearsons correlation coefficient and Bland-Altman plots, respectively (22). All data are presented as mean ± sd, and P < 0.05 was considered statistically significant.
One subject was excluded because of difficulty in placing the laryngeal mask airway. The mean age, weight, and height of the remaining nine volunteers were 25 ± 3 yr, 62.4 ± 5.2 kg, and 170 ± 3 cm, respectively. All of them were male. Compared with the conscious baseline value, SBP decreased significantly in a concentration-dependent manner during sevoflurane anesthesia and returned to the baseline value after emergence from anesthesia (Table 1). A significant increase in HR was seen 30 min after emergence from anesthesia compared with the awake baseline value. Compared with HR during 0.7% sevoflurane, significantly greater HR values were seen at 1.4% and 2.0% sevoflurane. The tympanic temperature in each individual was maintained within 0.2°C higher or lower than the conscious baseline value throughout the study.
Baroreflex gains assessed by the sequence method demonstrated concentration-dependent, significant decreases during sevoflurane anesthesia and remained depressed for 30 min after emergence (Fig. 1). Significant depressions of
Power spectral analysis of RRI revealed that both HF and LF were concentration-dependently depressed during sevoflurane anesthesia (Fig. 3). During the recovery period, HF power remained significantly depressed at 30 min and returned to the conscious baseline value from 60 to 180 min after emergence. LF power was similarly depressed in a concentration-dependent manner during sevoflurane anesthesia. After anesthesia, however, LF power rapidly recovered and was significantly more than the baseline value at the 120- and 180-min recovery periods. As a result, the LF/HF ratio remained unaltered during and for 60 min after sevoflurane anesthesia but was significantly more than the awake value from 120 to 180 min after emergence from anesthesia (data not shown). Conversely, the HF power of BPV was significantly increased during sevoflurane anesthesia without a concentration-dependent effect, whereas the LF power of BPV was significantly depressed by sevoflurane. Both HF and LF powers recovered rapidly after emergence from anesthesia (Fig. 4).
In general, there were highly significant positive correlations among various baroreflex indices during sevoflurane anesthesia, with the exception of the LF transfer function index (Table 2). The least-square regressions of these spontaneous indices against the pharmacological gains are shown in Figure 5. Because of the significant relations, the agreement was further analyzed by Bland-Altman plots (22), as shown in Figure 6. In each Bland-Altman plot, however, the limits of agreement (mean ± 1.96 sd) were as large as or exceeded the baroreflex gain itself, and 95% confidence intervals of the limits showed wide variations (Table 3), thus indicating weak agreement.
A major finding of our study is that spontaneous sequence gain is depressed by sevoflurane in a concentration-dependent manner and remains depressed during the immediate postanesthesia period (Fig. 1). A few previous investigations reported depressions of SBR indices by general anesthesia in humans. Van Vlymen and Parlow (11) found depressions of spontaneous sequence gains during propofol/fentanyl anesthesia, whereas Huang et al. (10) documented decreases in sequence gains by various concentrations of sevoflurane during minor surgery. Furthermore, depressions of spontaneous sequence gain and HF gain of cross-spectral analysis have been reported (23). However, none of those studies controlled depth of anesthesia, determined the dose-response relationship between anesthetics and SBR indices, or reported relation/agreement between pharmacological gains and spontaneous indices. The concentration-dependent depressions in spontaneous sequence gains and their recovery characteristics by sevoflurane in our study are remarkably similar to changes in pharmacological gains by volatile anesthetics, including sevoflurane (13). These results imply that the depth of anesthesia should be strictly controlled when a spontaneous sequence method is used to quantify cardiovagal baroreflex function. Except for the LF transfer function index, our results are in accordance with several previous reports (2,9) in which highly significant correlations were demonstrated between spontaneous indices and pharmacological baroreflex gains (Table 2). However, no previous study has further analyzed agreement between any spontaneous index and pharmacological gain. A more recent study by Lipman et al. (24) demonstrated poor agreement between pharmacological and spontaneous sequence gains in conscious humans. They also showed that carotid distensibility, a critical determinant of baroreflex sensitivity, was directly related to the pharmacological gain, but not to spontaneous indices. Their results, together with the present results, suggest that spontaneous indices may simply reflect beat-to-beat synchronous fluctuations of BP and RRI associated with respiratory-related changes in the intrathoracic pressure, but not arterial baroreflex function. Therefore, the lack of agreement shown by the Bland-Altman analysis in our study (Fig. 6, Table 3) does not support the utility of any spontaneous index as a surrogate for pharmacological gain during general anesthesia. Rather, spontaneous indices may be useful simply for qualitative assessments of beat-to-beat vagal modulation of HR. We have simultaneously performed frequency-domain analysis of RRI as one of the autonomic indices, because fluctuations of RRI reflect the beat-to-beat dynamic response of the autonomic nervous system to various physiological perturbations (21). The HF component of the HRV spectrum is considered to represent predominantly vagal modulation of the cardiac cycle, LF is thought to be under the influence of both the parasympathetic and sympathetic nervous systems, and the LF/HF ratio may reflect sympathetic predominance (21,25). Consistent with a previous report in which isoflurane concentration-dependently reduced the powers of both the HF and LF components without altering the LF/HF ratio (26), our results suggest that efferent autonomic nervous activity was diminished concentration dependently, but the relative balance of cardiac sympathetic and parasympathetic activities appeared to be maintained during sevoflurane anesthesia (Fig. 3). With respect to recovery characteristics, our results also agree with a report by Donchin et al. (27) in which the HF component remained depressed for 2030 minutes after 2 minimum alveolar anesthetic concentration of isoflurane and 70% nitrous oxide anesthesia. The recovery profile of spontaneous sequence baroreflex response in our study is similar to that of HF power after emergence from anesthesia. These results, together with previous reports, suggest that depressed SBR response and HF power during and after sevoflurane anesthesia are closely linked with impaired beat-to-beat vagal modulation of the cardiac cycle. In contrast, the HF power of BPV showed neither a depression nor a concentration-dependent effect by sevoflurane and returned to the baseline value immediately after discontinuance of sevoflurane and positive pressure ventilation (Fig. 4). Although vagally mediated changes in cardiac output may play a role in determining the HF power of BPV, the HF power of BPV is not substantially modified in patients with a denervated, transplanted heart (28). Therefore, the absence of concentration-dependent alterations of HF power of BPV in our study is more likely to reflect mechanical effects of positive pressure ventilation on pressure gradients of large thoracic vessels and functions of the heart rather than vagal influences.
Our study also demonstrated that the immediate recovery phase
The results of our study should be interpreted with some caution. First, a significant difference was not detected in up-sequence indices between end-tidal sevoflurane 0.7% and 1.4% and down-sequence indices between end-tidal sevoflurane 1.4% and 2.0%. In addition, a concentration-dependent depression in the
In conclusion, our results demonstrated that the spontaneous sequence baroreflex response was depressed in a concentration-dependent manner during, and remained depressed for 30 minutes after, sevoflurane anesthesia in humans. Spontaneous sequence gains and the
Accepted for publication October 6, 2004.
This article has been cited by other articles:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|