JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dunning, M. B.
Right arrow Articles by Woehlck, H. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dunning, M. B., III
Right arrow Articles by Woehlck, H. J.

Anesth Analg 2005;100:1541-1542
© 2005 International Anesthesia Research Society
doi: 10.1213/01.ANE.0000149047.06813.41


LETTER TO THE EDITOR

Measurement of Isoflurane and Desflurane Degradation

Marshall B. Dunning, III, PhD, MS, and Harvey J. Woehlck, MD

Division of Pulmonary/Critical Care Medicine; mdunning{at}mcw.edu (Dunning) Department of Anesthesiology; Medical College of Wisconsin; Milwaukee, WI (Woehlck)

To the Editor:

Laster et al. (1) suggest that only small amounts of isoflurane and desflurane are degraded in their studies of anesthetic absorbent fires. The monitoring device used for anesthetic concentrations was a monochromatic infrared monitor (RGM 5250, Ohmeda, Louisville, CO), which is prone to interference because the infrared absorbance is measured at a single wavelength. The reported anesthetic concentration is based on a user-entered calibration factor for each anesthetic. Because trifluoromethane (CHF3) is produced during the breakdown of isoflurane and desflurane (2), and interferes with anesthetic drug monitoring (3), CHF3 may cause falsely elevated reported concentrations of the selected anesthetic. Calculations (not shown) based on our study (3) demonstrate that the RGM 5250 monitor reports approximately 0.9% isoflurane or 1.2% desflurane for each 1% CHF3. The breakdown of 1 mole isoflurane or desflurane produces 0.23 and 0.84 moles of CHF3, respectively. Therefore, the reported concentration of isoflurane is falsely elevated by about 21% and desflurane by about 98% of the degraded amount due to the interference of CHF3. Thus, little if any change in reported desflurane concentration can result. Although the ratio of the amount of CHF3 produced for each mole of anesthetic degraded depends somewhat on reaction temperature (4), it is probable that little, if any, decrease in the concentration of desflurane can be detected by the RGM 5250 monitor because of the interference of CHF3. Figure 5 in Laster et al.’s article (1) may indicate little to no desflurane degradation as a result, and the discrepancy at the initial measurement may be due to temperature dependence, since the absorbent is under 25°C at that time.

References

  1. Laster M, Roth P, Eger EI II. Fires from the interaction of anesthetics with desiccated absorbent. Anesth Analg 2004;99:769–74.[Abstract/Free Full Text]
  2. Eger EI II, Strum D. The absorption and degradation of isoflurane and I-653 by dry soda lime at various temperatures. Anesth Analg 1987;66:1312–5.[Abstract/Free Full Text]
  3. Woehlck HJ, Dunning MB III, et al. The response of anesthetic agent monitors to trifluoromethane warns of the presence of carbon monoxide from anesthetic breakdown. J Clin Monit 1997;13:149–55.[ISI][Medline]
  4. Woehlck HJ, Dunning M III, Nithipatikom K, et al. Mass spectrometry provides warning of carbon monoxide exposure via trifluoromethane. Anesthesiology 1996;84:1489–93.[ISI][Medline]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dunning, M. B.
Right arrow Articles by Woehlck, H. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dunning, M. B., III
Right arrow Articles by Woehlck, H. J.


Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins with the assistance of Stanford University Libraries' HighWire Press®. Copyright 2006 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press