Anesth Analg 2006;102:1863-1864
© 2006 International Anesthesia Research Society
doi: 10.1213/01.ane.0000216037.69269.60
REGIONAL ANESTHESIA
Cauda Equina Syndrome and Profound Hearing Loss After Spinal Anesthesia with Isobaric Bupivacaine
Traore Moussa, MD,
Diallo Abdoulaye, MD,
Coulibaly Youssouf,
Guinto Cheick Oumar,
Timbo Samba Karim, and
Thomas Jeannette Traore
Department of Neurology, Department of Anesthesiology and Reanimation, Department of Otorhinolaryngology, Department of Ophthalmology, Point G Hospital, Medical School, Bamako, Mali
Address correspondence and reprint requests to Moussa Traore, Sr, MD, Medical school, Point G Hospital, Bamako, Mali 1805. Address e-mail to mtraore{at}mrtcbko.org.
 |
Abstract
|
|---|
A 33-yr-old man undergoing anorectal surgery developed cauda equina syndrome and bilateral profound hearing loss after single-injection spinal anesthesia with isobaric bupivacaine. There was no pain on needle placement. Neurologic assessment found impaired sensation to pinprick in the perineal region, lower extremity paralysis, and bowel and bladder incontinence. In addition, he developed a bilateral profound hearing loss involving the low frequencies, with the left side more affected than the right side. Although hearing impairment can occur with cerebrospinal fluid leakage, the etiology of cauda equina syndrome is uncertain. The simultaneous occurrence of these events has not been previously reported.
 |
Introduction
|
|---|
Serious neurologic deficits such as cauda equina syndrome and profound hearing loss after spinal anesthesia are relatively rare (17). We report the case of a patient who simultaneously developed cauda equina syndrome and profound hearing loss after uneventful spinal anesthesia with isobaric bupivacaine.
 |
Case Report
|
|---|
A 33-yr-old man in good health with no preexisting neurologic deficits presented for anorectal surgery under spinal anesthesia. Skin was cleansed with spinal polyvidone iodized at 5% (LTD/UK expiration 06/2006). With the patient in the sitting position, 2.5 mL of isobaric bupivacaine 0.5% (Multi M: expiration date 10/2006) was administered via a 22-gauge needle (Spinocan; Braun) at the L3-4 level. Clear cerebrospinal fluid was obtained on the first attempt without any blood or paresthesia. The equipment and drugs were prepackaged sterile kits and had been stored at 4°C. The patient was placed in the lithotomy position and in the Trendelenburg position. He reported transient attacks of vertigo lasting a few minutes immediately after bupivacaine administration. Within 10 min, the sensory level was noted to be T10 and complete lower extremity motor block was achieved. Surgical blood loss was not significant. Successful surgery was performed within 90 min. Six hours after administration of the spinal anesthetic, the patient was noted to have bilateral sensorimotor deficits of the lower extremity and impaired sensation to pinpricks in the perianal region. Urinary and fecal incontinence were also observed. A myelogram and a computed tomography scan performed the next day showed imaging within normal limits. Lumbosacral magnetic resonance imaging was not performed because this technology was not available. Cauda equina syndrome was diagnosed.
In addition to cauda equina syndrome, the patient experienced bilateral hearing loss. Audiometric testing was performed 3 mo and 6 mo after the spinal anesthetic using a diagnostic audiometer AF 12. The aural deficit was assessed by audiometry, and pure tone thresholds were recorded in frequencies 125 Hz to 8 kHz. Hearing loss was defined as a loss at 3 or more frequencies of 10 db. The hearing loss was bilateral and affected the low speech frequencies and the left side more than the right. The audiogram revealed worsening of 10 db pure tone average at the 0.5, 1, 2, 3, 4, 5, and 6 Hz hearing thresholds. These findings are consistent with a cochlear pathology induced by the lumbar puncture for spinal anesthesia.
Lower extremity weakness was still present 21 mo postoperatively, and the patient required catheterization and was unable to have a bowel movement spontaneously. In addition, the profound hearing loss persisted.
 |
Discussion
|
|---|
We describe a case of cauda equina syndrome characterized by urinary and fecal incontinence, perianal sensory loss and lower extremity weakness after routine spinal anesthesia with 0.5% isobaric bupivacaine. The patient simultaneously developed a persistent hearing loss. Although these major complications rarely occur after spinal anesthesia, our patient developed both (811).
The exact etiology of hearing loss after spinal anesthesia is unknown (12,13). However, some studies suggest that hearing loss can result whenever cerebrospinal fluid leakage occurs (14,15). Decreasing of perilymphatic pressure leads to acute endolymphatic hydrops (5), a histologic marker for Ménières syndrome (16). This syndrome is characterized by spontaneous attacks of vertigo, sensory hearing loss, aural fullness, and tinnitus (17). These symptoms were noted in the present case. Hearing loss after spinal anesthesia is typically related to needle size and is more frequent in young patients. In the present case, the patient was 33 years old and a 22-gauge needle was used (4,6,18).
The potential etiologies of cauda equina syndrome include direct or indirect trauma, lithotomy position, infection, and spinal cord compression (19). The lithotomy position by producing maldistribution of local anesthetic is a risk factor for cauda equina syndrome (20,21). In our case, no cause of spinal cord or nerve root compression was observed on the computed tomographic scan. Injections into the cord can readily produce bilateral deficits. Such cases are generally but not always associated with paresthesias at the time of lumbar puncture. In the present case no paresthesias were elicited with needle placement (22,23). However, the possibility of direct trauma cannot be excluded. In our case, the thoracic sensory level block was bilateral and reached T10 within 10 min after spinal anesthesia with 2.5 mL of isobaric bupivacaine; thus, maldistribution seems unlikely. Thus the explanation for cauda equina syndrome is uncertain and consequently speculative. Magnetic resonance imaging, which may have been helpful in assessing the potential etiologies, was not available.
In summary, we report two rare and serious complications of spinal anesthesia in the same patient after uneventful block performance.
 |
Footnotes
|
|---|
Accepted for publication January 26, 2006.
 |
References
|
|---|
- Kubina P, Gupta A, Oscarsson A, et al. Two cases of cauda equina syndrome following spinal-epidural anesthesia. Reg Anesth 1997;22:44750.[Web of Science][Medline]
- Ifuku Y, Iwagaki T, Irie J, et al. Cauda equina syndrome following intrathecal dibucaine. Masui 2004;53:3968.[Medline]
- Aromaa U, Lahdensuu M, Cozanitis DA. Severe complications associated with epidural and spinal anaesthesias in Finland 19871993: a study based on patient insurance claims. Acta Anaesthesiol Scand 1997;41:44552.[Web of Science][Medline]
- Naessens M, Kuhweide R, Ampe W. Hearing loss following lumbar puncture: Case report and literature study. Acta Otorhinolaryngol Belg 1994;48:3515.[Medline]
- Hussain SS, Heard CM, Bembridge JL. Hearing loss following spinal anaesthesia with bupivacaine. Clin Otolaryngol 1996;21:44954.[Medline]
- Kilickan L, Gurkan Y, Ozkarakas H. Permanent sensorineural hearing loss following spinal anesthesia. Acta Anaesthesiol Scand 2002;46:11557.[Medline]
- Moen V, Dahlgren N, Irestedt L. Severe neurological complications after central neuraxial blockades in Sweden 19901999. Anesthesiology 2004;101:9509.[Web of Science][Medline]
- Fog J, Wang LP, Sundberg A, Mucchiano C. Hearing loss after spinal anesthesia is related to needle size. Anesth Analg 1990;70:51722.[Abstract/Free Full Text]
- Loo CC, Irested L. Cauda equina syndrome after spinal anaesthesia with hyperbaric 5% lignocaine: a review of six cases of cauda equina syndrome reported to the Swedish Pharmaceutical Insurance 1993-1997. Acta Anaesthesiol Scand 1999;43:3719.[Web of Science][Medline]
- Navarro JL, Soria A, Herrera P, Montero R. Cauda equina syndrome after intradural anesthesia with bupivacaine. Rev Esp Anestesiol Reanim 2001;48:3379.[Medline]
- Lopez-Soriano F, Lajarin B, Verdu JM, et al. Cauda equina hemisyndrome after intradural anesthesia with bupivacaine for hip surgery. Rev Esp Anestesiol Reanim 2002;49:4946.[Medline]
- Gultekin S, Yilmaz N, Ceyhan A, et al. The effect of different anaesthetic agents in hearing loss following spinal anaesthesia. Eur J Anaesthesiol 1998;15:613.[Medline]
- Kilickan L, Gurkan Y, Aydin O, et al. The effect of combined spinal-epidural (CSE) anaesthesia and size of spinal needle on postoperative hearing loss after elective caesarean section. Clin Otolaryngol Allied Sci 2003;28:26772.
- Irvin SM.. Sensorineural hearing loss after select procedures. J Perianesth Nurs 2002;17:8998.[Medline]
- Cosar A, Yetiser S, Sizlan A, et al. Hearing impairment associated with spinal anesthesia. Acta Otolaryngol 2004;124:115964.[Medline]
- Merchant SN, Adams JC, Nadol JB Jr. Pathophysiology of Ménières syndrome: are symptoms caused by endolymphatic hydrops? Otol Neurotol 2005;26:7481.[Medline]
- Minor LB, Schessel DA, Carey JP. Menieres disease. Curr Opin Neurol 2004;17:916.[Web of Science][Medline]
- Gültekin S, Özcan S. Does hearing loss after spinal anesthesia differ between young and elderly patients? Anesth Analg 2002;94:131820.[Abstract/Free Full Text]
- Pleym H, Spigset O. Peripheralneurologic deficits in relation to subarachnoid or epidural administration of local anesthetics for surgery: a survey of 21 cases. Acta Anaesthesiol Scand 1997;41:453460.[Web of Science][Medline]
- Yorozu T, Matsumoto M, Hayashi S, et al. Dibucaine for spinal anesthesia is a probable risk for cauda equina syndrome [in Japanese]. Masui 2002;51:11514.[Medline]
- Biboulet P, Capdevila X, Aubas P, et al. Causes and prediction of maldistribution during continuous spinal anesthesia with isobaric or hyperbaric bupivacaine. Anesthesiology 1998;88:148794.[Web of Science][Medline]
- Tripathi M, Nath SS, Gupta RK. Paraplegia after intracord injection during attempted epidural steroid injection in an awake-patient. Anesth Analg 2005;101:120911.[Abstract/Free Full Text]
- Tsui BC, Armstrong K. Can direct spinal cord injury occur without paresthesia? A report of delayed spinal cord injury after epidural placement in an awake patient. Anesth Analg 2005;101:12124.[Abstract/Free Full Text]
|