JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mittnacht, A. J. C.
Right arrow Articles by Reich, D. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mittnacht, A. J. C.
Right arrow Articles by Reich, D. L.

Anesth Analg 2007;105:549-550
© 2007 International Anesthesia Research Society
doi: 10.1213/01.ane.0000265695.72785.9d


LETTER TO THE EDITOR

Section Editor:
Lawrence Saidman

Methylene Blue Administration Is Associated with Decreased Cerebral Oximetry Values

Alexander J. C. Mittnacht, MD, Gregory W. Fischer, MD, and David L. Reich, MD

Department of Anesthesiology; Mount Sinai Medical Center; New York, New York; alexander.mittnacht{at}msnyuhealth.org

To the Editor:

Methylene blue is administered to patients undergoing open heart surgery for treatment of a vasoplegic syndrome, which is characterized by high cardiac output, low systemic vascular resistance (SVR), and low systemic perfusion pressures, and is resistant to large doses of vasoconstrictors. As described in a recent publication, we administered methylene blue as an IV loading dose (2 mg/kg over 20 min), followed by continuous infusion (0.5 mg · kg–1 · h–1) when the attending cardiac anesthesiologist determined that a refractory case of vasoplegia is present (1). Concomitant with the initiation of the methylene blue loading dose, we noted that cerebral oximetry values (INVOS®, Somanetics, Troy, MI) declined markedly in all patients despite significant improvement in systemic perfusion pressure. The image below illustrates this phenomenon in two patients by replicating the INVOS monitor display.

In both patients, methylene blue was administered due to a vasoplegic syndrome that was unresponsive to high doses of vasoconstrictors (norepinephrine >0.4 mcg · kg–1 · min–1, vasopressin >8 U/h). In Patient 1, methylene blue was administered during cardiopulmonary bypass. Following the loading dose, the cerebral oximetry value declined by almost 70% to values in the low teens where it remained for the rest of the case, while the vasoconstrictor dosages were reduced significantly and mean arterial pressure (MAP) was adequate (50–60 mm Hg on cardiopulmonary bypass). In Patient 2, a vasoplegic syndrome was diagnosed upon separation from cardiopulmonary bypass. Coincident with the methylene blue bolus administration, the cerebral oximeter reading declined to values in the low 20 s. Transfusion of packed red blood cells to increase hemoglobin oxygen carrying capacity was associated with partial recovery of cerebral oximetry values; however, the values remained 30%–40% lower than the baseline before methylene blue administration. Both patients were discharged with no apparent neurological sequelae.

The absorption of light as it traverses tissues is affected by dye administration, so it is reasonable to expect that methylene blue administration should interfere with cerebral oximetry. Nevertheless, this phenomenon has not been described when methylene blue is administered to patients whose cerebral oxygenation is being monitored with near infrared spectroscopy (NIRS). Methylene blue has a dose- and time-dependent effect on plasma light absorbance, with a spectral absorption peak at 668 nm, resulting in falsely low pulse oximetry readings (2). The INVOS device uses two near-infrared wavelengths (730 and 805 nm) and measures the spectral absorbance of blood in brain tissue. Regional oxygen saturation is calculated as the ratio of oxyhemoglobin to total hemoglobin; however, the values must be interpreted according to the relative amounts of arterial and venous blood in brain tissue (typically 75% venous and 25% arterial). The manufacturer notes in the device manual that the administration of any dye can affect the measurement. There is no mention of the specific effects of methylene blue, however.

In contrast to the present report, we are aware of one other report where methylene blue was not noted to affect cerebral oximetry measurement (3). The exact NIRS device used is not mentioned in that brief communication. On the basis of our observations with the INVOS device, we caution clinicians to be aware of the potential for methylene blue to affect cerebral oximetry measurements.


Figure 174
View larger version (32K):
[in this window]
[in a new window]

 
Figure 1. Cerebral oximetry monitor displays for two patients. The arrows indicate the point in time when methylene blue was administered as an IV bolus.

 
REFERENCES

  1. Levin RL, Degrange MA, Bruno GF, DelMazo CD, Taborda DJ, Griotti JJ, Boullon FJ. Methylene blue reduces mortality and morbidity in vasoplegic patients after cardiac surgery. Ann Thorac Surg 2004;77:496–9[Abstract/Free Full Text]
  2. Sidi A, Paulus DA, Rush W, Gravenstein N, Davis RF. Methylene blue and indocyanine green artifactually lower pulse oximetry readings of oxygen saturation. Studies in dogs. J Clin Monit 1987;3:249–56[Web of Science][Medline]
  3. Tayler K, Holtby H. Methylene blue revisited: management of hypotension in a pediatric patient with bacterial endocarditis. J Thorac Cardiovasc Surg 2005;130:566[Free Full Text]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mittnacht, A. J. C.
Right arrow Articles by Reich, D. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mittnacht, A. J. C.
Right arrow Articles by Reich, D. L.


Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2007 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press