JOURNAL HOME CME HOME THIS MONTH PAST ISSUES ETOC COLLECTIONS
AUTHORS REVIEWERS EDITORIAL BOARD FEEDBACK RSS HELP
A&A International Anesthesia Research Society
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sinha, S. K.
Right arrow Articles by Weller, R. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sinha, S. K.
Right arrow Articles by Weller, R. S.
Related Collections
Right arrow Anesthetic Techniques
Right arrow Regional Anesthesia
Right arrow Technology

Anesth Analg 2007;105:848-852
© 2007 International Anesthesia Research Society
doi: 10.1213/01.ane.0000271912.84440.01


ANALGESIA

Section Editor:
Terese T. Horlocker

Ultrasound-Guided Interscalene Needle Placement Produces Successful Anesthesia Regardless of Motor Stimulation Above or Below 0.5 mA

Sanjay K. Sinha, MBBS*, Jonathan H. Abrams, MD*, and Robert S. Weller, MD{dagger}

From the *Department of Anesthesiology, Saint Francis Hospital and Medical Center, Hartford, Connecticut; and {dagger}Department of Anesthesiology, Wake Forest University School of Medicine, Winston-Salem, North Carolina.

Address correspondence to Robert S. Weller, MD, Department of Anesthesiology, Wake Forest University School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157-1009. Address e-mail to rweller{at}wfubmc.edu.

Abstract

BACKGROUND: We quantified the motor response after ultrasound (U-S)-guided needle placement for interscalene block (ISB). We then compared block characteristics based on motor response above or below 0.5 mA.

METHODS: Sixty-one patients scheduled for ambulatory shoulder surgery under ISB and general anesthesia were included in this prospective, observational study. Preoperatively, an insulated needle was positioned by U-S in the interscalene groove. The lowest current producing motor response was determined, and 30 mL 0.5% bupivacaine with epinephrine was injected. Motor and sensory block were tested in the upper trunk distribution for 15 min until general anesthesia was induced. Postoperatively, the success of upper trunk block, pain score in the postanesthesia care unit and block duration, and analgesic tablet consumption overnight were recorded. Patients were divided a priori into Group A (current ≤0.5 mA) and Group B (current >0.5 mA), and results were compared between groups.

RESULTS: The observed current range was 0.14–1.7 mA, with current ≤0.5 mA in 42% of patients (Group A). All patients had complete sensorimotor upper trunk block and none required narcotics in the postanesthesia care unit. Block duration (both groups: 17.8 ± 4.9 h, mean ± sd) and home analgesic use were equivalent. Sensory block onset was equivalent between groups, but incomplete motor block at 15 min was more likely in Group B: 37% vs 12% in Group A (P = 0.03).

CONCLUSION: During U-S-guided ISB using nerve stimulation, the observed motor response below or above 0.5 mA had no impact on success or duration of upper trunk block.

Ultrasound (U-S) guidance is being increasingly used for performing peripheral nerve blocks (1,2). Unlike more traditional peripheral nerve block techniques, in which a sensory paresthesia is elicited or motor nerve stimulation is performed, U-S guidance uses an anatomic rather than a neurophysiologic end point for block performance. Anesthesiologists, however, often continue to use nerve stimulation along with U-S guidance for additional confirmation of nerve identification (2).

With motor nerve stimulation, the most commonly accepted end point for evidence that an insulated, stimulating needle is close enough to the target nerve to result in reliable anesthesia is a motor response at or below 0.5 mA (3). When using both U-S and motor nerve stimulation for performing interscalene block (ISB) it has been noted that, despite sonographic evidence of the needle tip in close proximity to the nerves, motor response cannot be consistently achieved at or below 0.5 mA (4). In this situation, the clinician must decide whether to accept the U-S evidence of needle placement in the interscalene space or to reposition the needle to evoke a motor response before injecting local anesthetic (LA). The objective of this study was to evaluate any differences in block characteristics or success based on whether the current observed to evoke a motor response was above or below 0.5 mA after U-S-guided needle placement in the interscalene space.

METHODS

Sixty-one patients scheduled for outpatient shoulder surgery under ISB and general anesthesia (GA) at St. Francis Hospital gave written, informed consent to participate in this IRB-approved study. Exclusion criteria included age <18 years or >70 years, pregnancy, neuropathy, neurologic disease, diabetes, or contraindication to ISB. After application of standard monitors, patients were lightly sedated in an induction area and supplemental oxygen was administered by a nasal cannula. The maximum sedation administered was 2 mg midazolam and 100 µg fentanyl, and verbal responsiveness was maintained throughout the block. The nerves in the interscalene space were identified by U-S (Titan®, SonoSite Inc., Bothell, WA), at approximately the level of the cricoid cartilage in the transverse or short-axis view. The footprint of the linear, 5–10 mHz transducer was then outlined by a marking pen, the skin was prepped and draped in a sterile fashion, and the transducer was enclosed in a sterile sleeve. After skin anesthesia, a 50-mm, 22-guage insulated needle (Stim-A2250, B. Braun Medical, Inc., Bethlehem, PA) was advanced under U-S guidance until the tip of the needle was between the two most lateral nerves in the interscalene space (Fig. 1). These nerve structures are most likely the C5 and C6 roots, or the upper trunk and the C7 root/middle trunk (5). The block needle was advanced in the long axis of the transducer (in plane), so that the shaft and tip of the needle were always in view (Fig. 1). Once the tip of the needle was positioned, the needle was immobilized and nerve stimulation was initiated at 0.1 ms pulse width, 2 Hz, (Stimuplex®, B. Braun Medical Inc., Bethlehem, PA). The current was increased slowly until a brachial plexus motor response was noted in the upper extremity (deltoid, bicep, tricep, brachioradialis) and this current was recorded. Because a variety of motor responses have resulted in successful interscalene anesthesia (6,7), the specific motor response elicited was not recorded for group stratification. Without any further needle movement, and after negative aspiration, 30 mL of bupivacaine 0.5% with epinephrine 1:200,000 was injected incrementally over 2–3 min with intermittent negative aspiration.


Figure 145
View larger version (51K):
[in this window]
[in a new window]

 
Figure 1. Transverse ultrasound image of interscalene needle placement at the cricoid level. Three hypoechoic, round nerve structures are visualized between the anterior and middle scalene muscles. The needle is seen passing through the middle scalene from posterior to anterior, with its tip between the two most lateral nerve structures.

 

The end of bupivacaine injection was denoted time zero, and the onset of sensory and motor blockade was assessed at 5, 10, and 15 min by a participating nurse. This nurse was not blinded to current measurement, but was unaware of the 0.5 mA group determinate. A three-point scale was used to assess sensory and motor block in the upper trunk (C5–6) distribution: normal, partial block, or complete block. Complete upper trunk sensory block was defined as absence of pain with 50 Hz, 30 mA tetanic stimulation in the anatomical snuffbox (MiniStim MS-1, Life-Tech Inc., Stafford, TX). The dermatomal innervation of the snuffbox is typically depicted as C6, although C7 may contribute. Complete upper trunk motor block was defined as the inability to flex the elbow against gravity (biceps—C5–6). The time to perform the block (from preblock scan with skin marking, to the end of injection) was also recorded.

Anesthesia was induced with propofol, tracheal intubation was facilitated by rocuronium, and GA was maintained with desflurane, nitrous oxide, oxygen, and fentanyl without specific limitation. The pre- and intraoperative fentanyl dosages were recorded. After emergence and tracheal extubation, patients were reassessed in the postanesthesia care unit (PACU) for upper trunk block quality and pain level. The sensory and motor blocks were reassessed with the same three-point scale used preoperatively, a 10-point numerical pain score was determined, and PACU fentanyl use was recorded as was surgical duration. Surgeons were asked (post hoc) to categorize the surgical procedures as moderate, moderately severe, or severe with respect to level of surgical trauma and expected nociception.

After discharge, nurses contacted the patient on postoperative day 1 and block duration, home analgesic consumption, patient satisfaction, and any complications were recorded. Block duration was defined as the time to first oral narcotic analgesic, or if none was required, the time to resolution of numbness in the arm. The nurse(s) performing the postoperative sensorimotor examination and the phone follow-up call were not blinded to current measurement, but were unaware of the group designation based on current (see below).

Based on the observed current required to elicit a motor response, patients were divided a priori into Group A (current ≤0.5 mA) and Group B (current >0.5 mA). Differences between groups were evaluated using independent samples t-test for data that had at least interval properties, (e.g., age, body mass index) and {chi}2 test for difference in frequency data (e.g., gender). All relevant comparisons were two-sided and {alpha} was set at 0.05. The home analgesic consumption was converted to hydrocodone equivalents and acetaminophen consumption, and these nonparametric data were analyzed using Mann– Whitney U.

RESULTS

Twenty-five patients, or 42%, had motor threshold current ≤0.5 mA (Group A), whereas 35 (58%) had response current above 0.5 mA (Group B) (Fig. 2). One patient was excluded for protocol violation and another patient experienced a transient paresthesia at final needle positioning; current measurement was performed at that site.


Figure 245
View larger version (18K):
[in this window]
[in a new window]

 
Figure 2. (A) Scattergram of threshold motor response current for each patient. (B) Histogram of frequency of each threshold motor current measurement. Mean (sd) = 0.67 mA (0.36).

 

No differences were noted in group characteristics, including demographics, preoperative and surgical narcotic use, block performance time, and surgical duration and intensity, as rated by the surgeon (Table 1). There was no difference in the progression of complete upper trunk sensory block between the groups: 96% in Group A and 91.4% in Group B had complete sensory block at 15 min (P = 0.46). However, fewer patients had complete upper trunk motor blockade at 15 min in Group B (62.9%) than in Group A (88%) P = 0.03 (Table 2). All patients had complete upper trunk sensory and motor block in the PACU. No patient was given fentanyl in the PACU because visual analog scale pain scores were 0 in all cases.


View this table:
[in this window]
[in a new window]

 
Table 1. Comparison of Group Characteristics

 

View this table:
[in this window]
[in a new window]

 
Table 2. Outcome Comparison between Groups

 

Block duration in Group A, mean 17.8 h (range 10.2–26.7 h), was not different from Group B, mean 17.8 h (range 9.0–27.1 h). In addition, the mean hydrocodone equivalents and acetaminophen consumed postoperatively did not differ between groups (Table 2).

DISCUSSION

U-S needle placement between the two most lateral interscalene nerve structures resulted in successful postoperative upper trunk block regardless of motor response from 0.14 to 1.7 mA. Although the onset of complete upper trunk sensory block was not different between groups, there was a delay in onset of complete upper trunk motor block in patients with current above 0.5 mA. This finding may have been because of the nonhomogenous distribution of motor, sensory, and connective tissue in nerve roots (8,9), such that a needle may have been proximate to one fiber type whereas at some distance from another type (10). Because the current density is inversely related to the distance from needle tip to motor fascicle (11), one might expect a slower onset of motor blockade in patients who required >0.5 mA to evoke a motor response. Other authors have shown that, for both ISB and axillary block, the needle location which produces a sensory paresthesia will not necessarily produce a motor response at a low current and vice versa (12–14). In a study of U-S-guided needle placement and motor response during axillary block, U-S-guided direct nerve contact resulted in motor response above 0.5 mA in 25.5% of cases (15). A higher percentage (58%) of patients in our study had motor response above 0.5 mA, perhaps because the needle was placed between nerve structures and between the fasciae of the anterior and middle scalene muscles rather than directed against a nerve.

A shortcoming of the study is that complete characterization of the onset of block was not performed after 15 min, and the sensory and motor block was only assessed in the C5–6 dermatome and myotome. In a practice setting where patients receive a block for postoperative analgesia and also undergo GA for shoulder surgery, the most important end point was considered to be the adequacy and duration of postoperative upper trunk block, because this may be all that is necessary for shoulder analgesia (16). Also, successful ISB often spares lower trunk anesthesia unpredictably (17). Extrapolation of the results of this study of U-S-guided ISB to production of anesthesia of the entire brachial plexus cannot be made.

An additional shortcoming of the study design is that the PACU nurses recorded outcome data, and they were not blinded to the current determined during block performance. They were not, however, aware of the predetermined group division at 0.5 mA, which should reduce the potential for bias. Finally, the U-S appearance of the spread of LA was not characterized, because needle movement was not allowed after initiating injection; optimizing LA spread by needle movement would have invalidated the current measurement.

In summary, U-S-guided interscalene needle placement without further adjustment for the current amplitude required to elicit a motor response resulted in successful postoperative upper trunk anesthesia in all 60 patients studied. Onset of complete biceps paralysis was delayed in patients with motor response above 0.5 mA, but there was no difference in upper trunk sensory block onset which was complete by 15 min in 93% of patients, and there was no difference in the postoperative success or duration of the ISB.

Footnotes

Accepted for publication May 14, 2007.

Funding was provided solely from intramural departmental funding (both departments).

Presented in part at the 2006 Annual Spring Meeting of the American Society of Regional Anesthesia, April 6–9, 2006, Rancho Mirage, CA.

Reprints will not be available from the author.

REFERENCES

  1. Marhofer P, Greher M, Kapral S. Ultrasound guidance in regional anaesthesia. Br J Anaesth 2005;94:7–17[Abstract/Free Full Text]
  2. Gray AT. Ultrasound-guided regional anesthesia: current state of the art. Anesthesiology 2006;104:368–73[Web of Science][Medline]
  3. Bashein G, Haschke RH, Ready B. Electrical nerve location: numerical and electrophoretic comparison of insulated vs. uninsulated needles. Anesth Analg 1984;63:919–24[Abstract/Free Full Text]
  4. Perlas A, Chan VW, Simons M. Brachial plexus examination and localization using ultrasound and electrical stimulation: a volunteer study. Anesthesiology 2003;99:429–35[Web of Science][Medline]
  5. Martinoli C, Bianchi S, Santacroce E, Pugliese F, Graif M, Derchi LE. Brachial plexus sonography: a technique for assessing the root level. AJR Am J Roentgenol 2002;179:699–702[Abstract/Free Full Text]
  6. Tonidandel WL, Mayfield JB. Successful interscalene block with a nerve stimulator may also result after a pectoralis major motor response. Reg Anesth Pain Med 2002;27:491–3[Web of Science][Medline]
  7. Silverstein WB, Saiyed MU, Brown AR. Interscalene block with a nerve stimulator: a deltoid motor response is a satisfactory endpoint for successful block. Reg Anesth Pain Med 2000;25:356–9[Web of Science][Medline]
  8. Kawai H. Anatomy of the brachial plexus. In: Kawai H, Kawabata H, eds. Brachial plexus palsy. Hackensack, NJ: World Scientific Publishing Co., 2000:1–24
  9. Sunderland S. The intraneural topography of the radial, median, and ulnar nerves. Brain 1945;68:243–98[Free Full Text]
  10. Hogan Q. Finding nerves is not simple. Reg Anesth Pain Med 2003;28:367–71[Web of Science][Medline]
  11. Pither CE, Raj PP, Ford DJ. The use of peripheral nerve stimulators for regional anesthesia: a review of experimental characteristics, technique, and clinical applications. Reg Anesth 1985;10:49–58
  12. Urmey WF, Stanton J. Inability to consistently elicit a motor response following sensory paresthesia during interscalene block administration. Anesthesiology 2002;96:552–4[Web of Science][Medline]
  13. Choyce A, Chan VW, Middleton WJ, Knight PR, Peng P, McCartney CJ. What is the relationship between paresthesia and nerve stimulation for axillary brachial plexus block? Reg Anesth Pain Med 2001;26:100–4[Web of Science][Medline]
  14. Karaca P, Hadzic A, Yufa M, Vloka JD, Brown AR, Visan A, Sanborn K, Santos AC. Painful paresthesiae are infrequent during brachial plexus localization using low-current peripheral nerve stimulation. Reg Anesth Pain Med 2003;28:380–3[Web of Science][Medline]
  15. Perlas A, Niazi A, McCartney C, Chan V, Xu D, Abbas S. The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound. Reg Anesth Pain Med 2006;31:445–50[Web of Science][Medline]
  16. Neal JM, Hebl JR, Gerancher JC, Hogan QH. Brachial plexus anesthesia: essentials of our current understanding. Reg Anesth Pain Med 2002;27:402–28[Web of Science][Medline]
  17. Brown DL, Bridenbaugh LD. The upper extremity: somatic block. In: Cousins MJ, Bridenbaugh PO, eds. Neural blockade in clinical anesthesia and management of pain. 3rd ed. Philadelphia: Lippincott-Raven, 1998:351



This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. S. Liu, V. M. Zayas, M. A. Gordon, J. C. Beathe, D. B. Maalouf, L. Paroli, G. A. Liguori, J. Ortiz, V. Buschiazzo, J. Ngeow, et al.
A Prospective, Randomized, Controlled Trial Comparing Ultrasound Versus Nerve Stimulator Guidance for Interscalene Block for Ambulatory Shoulder Surgery for Postoperative Neurological Symptoms
Anesth. Analg., July 1, 2009; 109(1): 265 - 271.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. J. Fredrickson, C. M. Ball, A. J. Dalgleish, A. W. Stewart, and T. G. Short
A Prospective Randomized Comparison of Ultrasound and Neurostimulation as Needle End Points for Interscalene Catheter Placement
Anesth. Analg., May 1, 2009; 108(5): 1695 - 1700.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sinha, S. K.
Right arrow Articles by Weller, R. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sinha, S. K.
Right arrow Articles by Weller, R. S.
Related Collections
Right arrow Anesthetic Techniques
Right arrow Regional Anesthesia
Right arrow Technology


Lippincott, Williams & Wilkins Anesthesia & Analgesia® is published for the International Anesthesia Research Society® by Lippincott Williams & Wilkins and Stanford University Libraries' HighWire Press®. Copyright 2007 by the International Anesthesia Research Society. Online ISSN: 1526-7598   Print ISSN: 0003-2999 HighWire Press