Department of Anesthesiology, College of Medicine, Dong-A University, Pusan, Korea
Address correspondence and reprint request to Chan-Jong Chung, MD, Department of Anesthesiology, Dong-A University Hospital, Dongdaesin-dong, Seo-gu, Pusan 602-715, Korea. Address e-mail to cjchung{at}daunet.donga.ac.kr
| Abstract |
|---|
|
|
|---|
Implications: Eighteen milligrams of 0.5% hyperbaric ropivacaine provided effective spinalanesthesia with shorter duration of sensory and motor block, compared with 12mg of 0.5% hyperbaric bupivacaine when administered for cesareandelivery.
| Introduction |
|---|
|
|
|---|
The efficacy and dosage of spinal ropivacaine for cesarean delivery is unknown. Based on several previous studies (7,8) as well as data from a pilot study, we determined that 18 mg of 0.5% hyperbaric ropivacaine was comparable to 12 mg of 0.5% hyperbaric bupivacaine for spinal anesthesia in cesarean delivery.
The purpose of this study was to evaluate the efficacy and safety of spinal anesthesia with 0.5% hyperbaric ropivacaine, compared with 0.5% hyperbaric bupivacaine for elective cesarean delivery.
| Methods |
|---|
|
|
|---|
Per standard hospital protocol, all patients received premedication with glycopyrrolate 0.2 mg and ranitidine 10 mg IM 1 h before the spinal procedure. Lactated Ringers solution 15 mL/kg was infused for 10 min before the initiation of the spinal block. Spinal anesthesia was performed in the right lateral position with a 25-gauge Quincke needle by using a midline approach at the L2-3 or L3-4 interspace. Once free flow of clear cerebrospinal fluid was obtained, the study drug was injected at the rate of approximately 0.2 mL/s. With the spinal needle bevel facing cephalad, the anesthetic solution was injected without barbotage or aspiration. After the injection of the spinal medication, the patients were turned supine with left uterine displacement. Maternal heart rate and arterial blood pressure were measured with an automatic, noninvasive device. Baseline values were defined as blood pressure and heart rate values before the preanesthetic infusion. The values were recorded before the induction, every 2 min before delivery, and then every 5 min until discharge from the recovery room. Arterial oxygen saturation was continuously monitored by using pulse oximetry throughout surgery. Hypotension (defined as systolic blood pressure < 100 mm Hg) was treated with IV ephedrine 10 mg and additional lactated Ringers solution. Maternal bradycardia (defined as heart rate < 60 bpm) was treated with IV atropine 0.5 mg. Nausea or vomiting was treated with IV droperidol 0.5 mg. IV midazolam 2.5 mg was administered only after the delivery if the patients requested to sleep. If pain or discomfort occurred during surgery, IV fentanyl 50 µg was administered. Oxygen was routinely administered via a face mask at the rate of 5 L/min until the end of surgery. Surgery was started when a sensory block at or above the T6 dermatome was established. The condition of the neonate was evaluated by Apgar scores at 1 and 5 min after delivery and by umbilical venous or arterial pH.
The assessments of sensory block to pinprick were performed at 2, 4, 6, 8, 10, and 15 min after the intrathecal injection and then every 15 min until regression to L5. Results of the pinprick test were determined bilaterally at midclavicular level by using a short-beveled 27-gauge needle. Motor block in the lower limb was assessed by using a modified Bromage scale (0 = no paralysis, 1 = unable to raise extended leg, 2 = unable to flex knee, 3 = unable to flex ankle). These assessments were performed immediately after the assessments of sensory block until the return of normal motor function.
The quality of abdominal muscle relaxation was evaluated by the surgeon at the end of the surgery as excellent (no disturbing muscle strain), satisfactory (disturbing, but acceptable muscle strain), or unsatisfactory (unacceptable muscle strain). The overall quality of intraoperative analgesia was judged by the investigator at the end of surgery as excellent (no discomfort or pain), good (mild pain or discomfort, no need for additional analgesics), fair (pain that required additional analgesics), or poor (moderate or severe pain that needed more than fentanyl 100 µg or general anesthesia). Time to the first feeling of pain (complete analgesia) and time to first request of analgesics (effective analgesia) were measured. On postoperative Days 1 and 5, patients were evaluated regarding possible side effects including headache, back pain, and transient neurologic symptoms.
A power analysis was based on data from a pilot study of 15 patients in which the mean duration of motor blockade was measured with ropivacaine and compared with the previous data for bupivacaine (9,10). To detect a 30-min difference in mean duration of motor blockade between the groups for type 1 error of 0.01 and a power of 90%, a group size of 32 patients was necessary.
Data were expressed as mean ± SD, median (range), or frequencies (%), as appropriate. Continuous variables were analyzed by using unpaired t-test. Nominal or ordinal variables were analyzed by using
2 test and Fishers exact test or Mann-Whitney U-test. P < 0.05 was considered statistically significant.
| Results |
|---|
|
|
|---|
|
|
|
|
9 at 5 min, and umbilical arterial or venous pH did not differ between groups (Bupivacaine = 7.24 ± 0.04, 7.31 ± 0.06; Ropivacaine = 7.25 ± 0.06, 7.33 ± 0.05). Hypotension was the most common side effect in both groups. The incidence of hypotension (80% vs 66.9%), mean ephedrine use (11.3 ± 7.3 mg vs 7.7 ± 6.2 mg), and maximal percent decrease in systolic arterial pressure (-27.4 ± 11.1% vs -23.7 ± 11.0%) or heart rate (-21.3 ± 12.4% vs -18.7 ± 10.1%) did not differ between groups. The incidence of bradycardia, dyspnea, nausea or vomiting, and shivering during surgery did not differ between groups (Table 4). None of the patients developed postdural puncture headache or transient neurologic symptoms. Ten patients in the Bupivacaine and eight patients in the Ropivacaine group complained of mild or moderate backache. These backaches did not radiate to other areas, but were localized in the lumbosacral area.
|
| Discussion |
|---|
|
|
|---|
The analgesic spread with isobaric spinal ropivacaine is variable, extending from lumbosacral segments to upper thoracic segments (57). Actually, glucose-free ropivacaine and bupivacaine solutions are not isobaric at body temperature. Like glucose-free bupivacaine 0.5% solutions (baricity at 37°C: 0.9990), glucose-free ropivacaine solutions (baricity at 37°C: 0.9988) will behave as slightly hypobaric at body temperature. Consequently, the injection of glucose-free ropivacaine solutions may result in a higher spread when the patient is kept in the sitting position for at least 2 min after the injection, as has been demonstrated for bupivacaine. Plain spinal bupivacaine for cesarean delivery is unreliable and occasionally produces high spinal block (11,12). Therefore, a hyperbaric solution for spinal anesthesia, especially for cesarean delivery, is considered superior to an isobaric solution. The optimal dosage of spinal ropivacaine for cesarean delivery is unknown. The equipotent ratio between bupivacaine and ropivacaine has been 3:2 with isobaric solution for knee arthroscopy (7) or 2:1 with hyperbaric solution in volunteers (8). Based on previous studies (7,8) and our pilot studies, we determined that 18 mg of 0.5% hyperbaric ropivacaine was comparable to 12 mg of 0.5% hyperbaric bupivacaine for spinal anesthesia in cesarean delivery. Further studies, including a dose-response study, are required to determine the optimal dose, concentration, and baricity of spinal ropivacaine for cesarean delivery.
Ropivacaine is a relatively new local anesthetic that has not been marketed for intrathecal use. In this study, hyperbaric ropivacaine solutions were made with 4 mL of 0.75% ropivacaine (Naropin®) and 2 mL of 20% dextrose. The specific gravity of 0.5% ropivacaine in 6.7% glucose was 1.030 at 23°C. The specific gravity of 0.5% hyperbaric bupivacaine in 8% glucose (Marcaine®) was 1.030 at 23°C.
Epidural ropivacaine is associated with similar duration of sensory block, compared with epidural bupivacaine for cesarean delivery (24). When hyperbaric bupivacaine 8 mg was compared with hyperbaric ropivacaine 12 mg in volunteers, no difference in time to peak sensory level and duration of sensory block was found (8). Our data showed that the time to peak sensory block was later and the duration of sensory block was shorter in patients who received ropivacaine for cesarean delivery. The difference in the time to peak sensory block between groups, however, was not clinically significant.
These results confirm that spinal ropivacaine is less potent than bupivacaine. The lesser lipid solubility of ropivacaine may cause this drug to penetrate the large myelinated A fibers more slowly than the more lipid-soluble bupivacaine (13). A difference in the potency between ropivacaine and bupivacaine has been 20%40% and 50% in epidural (14,15) and spinal (7,8) studies, respectively. Ropivacaine produces less motor blockade at the same dose as bupivacaine because it is less potent. Studies evaluating the use of intrathecal ropivacaine for ambulatory surgery (7,8) have reported that spinal ropivacaine offers no advantages over bupivacaine for use in outpatients. Spinal ropivacaine 12 mg has produced motor blockade equivalent to bupivacaine 8 mg (8). However, in this study, hyperbaric ropivacaine 18 mg produced a significantly shorter duration of motor blockade than hyperbaric bupivacaine 12 mg (P < 0.001). Although the patients satisfaction to recovery of motor block was not assessed clinically and objectively in this study, earlier recovery with spinal ropivacaine may be associated with more patient satisfaction.
In this study, intrathecal ropivacaine produced excellent intraoperative analgesia and abdominal muscle relaxation, indistinguishable from spinal bupivacaine. Small supplementary doses of IV analgesics (fentanyl 50 µg) were administered to three patients in the Ropivacaine group during the last part of the surgery. The duration of sensory block was shorter and the time to first request of analgesics was earlier with ropivacaine than with bupivacaine in this study. Cesarean delivery sometimes takes more than 1.5 hours. If that occurred, spinal ropivacaine might produce a block of inadequate duration. Adding an opioid to hyperbaric ropivacaine would improve the quality of anesthesia, similar to adding an opioid to hyperbaric bupivacaine (10).
The incidence of hypotension is frequent in both groups (80%67%). Mean maximal reduction of maternal systolic pressure or heart rate, mean ephedrine use, and incidence of hypotension did not differ between groups. The hypotension was easily treated with ephedrine and did not cause maternal or fetal sequelae. In this study, the conditions of the neonates were good and similar in both groups. The number of neonates with unsatisfactory Apgar scores or umbilical blood pH values did not differ between groups. Backache is a common complaint during both pregnancy and the postpartum period. In this study, backache occurred in 30% of the patients with bupivacaine and 28% of the patients with ropivacaine. The relatively frequent incidence of backache in our patients was not likely to have been caused by neurotoxic effects of bupivacaine or ropivacaine. These backaches were mild or moderate and were localized only in the lumbosacral area. Kristensen et al. (16) reported that spinal ropivacaine does not affect spinal cord blood flow. As in other studies (58), spinal ropivacaine did not induce any neurologic symptoms in this study.
In conclusion, 18 mg of 0.5% hyperbaric ropivacaine provided similar and effective spinal anesthesia with shorter duration of sensory and motor block, compared with 12 mg of 0.5% hyperbaric bupivacaine for cesarean delivery.
| Acknowledgments |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
P. D. W. Fettes, G. Hocking, M. K. Peterson, J. F. Luck, and J. A. W. Wildsmith Comparison of plain and hyperbaric solutions of ropivacaine for spinal anaesthesia Br. J. Anaesth., January 1, 2005; 94(1): 107 - 111. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kallio, E.-V. T. Snall, C. A. Tuomas, and P. H. Rosenberg Comparison of hyperbaric and plain ropivacaine 15 mg in spinal anaesthesia for lower limb surgery Br. J. Anaesth., November 1, 2004; 93(5): 664 - 669. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kallio, E.-V. T. Snall, M. P. Kero, and P. H. Rosenberg A Comparison of Intrathecal Plain Solutions Containing Ropivacaine 20 or 15 mg Versus Bupivacaine 10 mg Anesth. Analg., September 1, 2004; 99(3): 713 - 717. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. O. Ogun, E. N. Kirgiz, A. Duman, S. Okesli, and C. Akyurek Comparison of intrathecal isobaric bupivacaine-morphine and ropivacaine-morphine for Caesarean delivery{dagger} Br. J. Anaesth., May 1, 2003; 90(5): 659 - 664. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. S. Khaw, W. D. Ngan Kee, M. Wong, F. Ng, and A. Lee Spinal Ropivacaine for Cesarean Delivery: A Comparison of Hyperbaric and Plain Solutions Anesth. Analg., March 1, 2002; 94(3): 680 - 685. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|