| ||||||||||||||
|
|
|||||||||||||



*Department of Anesthesiology, UMDNJ-Robert Wood Johnson Medical School, New Brunswick, New Jersey;
Department of Anesthesiology, College of Physicians and Surgeons of Columbia University, New York, New York; and
Department of Anesthesiology, Weill Medical College of Cornell University, New York, New York
Address correspondence to Shaul Cohen, MD, Chief of Obstetric Anesthesia, Department of Anesthesia, UMDNJ-Robert Wood Johnson Medical School, CAB, Suite 3100, 125 Paterson Street, New Brunswick, NJ 08903. Address e-mail to cohensh{at}umdnj.edu
| Abstract |
|---|
|
|
|---|
IMPLICATIONS: Fentanyl administered epidurally to parturients after cesarean delivery has a primarily spinal mechanism of action and this effect is enhanced by very small dose epidural bupivacaine and epinephrine.
| Introduction |
|---|
|
|
|---|
We tested the hypotheses that epidural fentanyl in postsurgical obstetric patients also acts primarily by a spinal mechanism and that the opioid sparing effect that we have seen (3,12) when very small dose local anesthetic plus epinephrine is administered epidurally together with fentanyl requires an interaction of these drugs at the spinal level. We compared the use of fentanyl administered by patient-controlled analgesia (PCA) epidurally or IV with or without bupivacaine and epinephrine infused at a constant rate into the epidural space. In addition, we compared the effects of these treatments on neurobehavioral scores of breast-fed neonates and determined plasma and colostrum fentanyl concentrations in a subset of patients from each group.
| Materials and Methods |
|---|
|
|
|---|
After the patients received an IV infusion of 1.52 L of lactated Ringers solution, continuous lumbar epidural anesthesia to achieve a T46 sensory level was established by injecting 3 mL followed by 18 mL of lidocaine 2%, fentanyl 5 µg/mL, and epinephrine 5 µg/mL via a closed end Braun 19-gauge catheter (B. Braun Medical Inc., Bethlehem, PA) placed at the L34 interspace. The catheter was directed cephalad 5 cm into the epidural space. All patients had a urethral catheter placed. During surgery, the patients were maintained supine with left uterine displacement and monitored continuously with an automated blood pressure cuff, electrocardiogram, and pulse oximeter. Oxygen was supplied by face mask at 6 L/min until the baby was delivered. No additional opioids were administered before the delivery of the baby. After delivery, oxytocin 0.02 U/mL was infused for a duration of 68 h.
On arrival in the postanesthesia care unit (PACU), patients were randomly allocated in a double-blinded fashion to four equal groups according to a previously generated table of random numbers. Groups I-BeFe (epidural bupivacaine and epidural fentanyl) and II-BeFi (epidural bupivacaine and intravenous fentanyl) received a continuous 12 mL/h epidural infusion of bupivacaine (0.015%) with epinephrine (1 µg/mL) for 48 h. Groups III-SeFi (epidural saline and intravenous fentanyl) and IV-SeFe (epidural saline and epidural fentanyl) received a 12 mL/h epidural saline infusion for 48 h. Fentanyl (20 µg/mL) was administered via a portable PCA-device (Abbott Pain Management Provider; Abbott Laboratories, North Chicago, IL) either into the epidural infusion (Groups I-BeFe and IV-SeFe) or IV (Groups II-BeFi and III-SeFi). The epidural bupivacaine and saline solutions were prepared in 800-mL coded bags and the fentanyl solutions were prepared in 100-mL bags. The fentanyl-PCA device was connected to both the IV catheter and the epidural catheter by means of a hidden three-way stopcock. Neither the investigator involved in the management and assessment of the patient nor the patient was aware of which epidural infusion solution was being given or the route of administration of the fentanyl solution. Each patient received an initial fentanyl infusion of 2 mL/h (20 µg/mL) and was allowed self-administered PCA boluses of 1 mL (20 µg/mL) with a 10-min lockout time; 6 boluses were allowed in 1 h.
Every 4 h, or sooner if requested, an investigator evaluated the patient for side effects, complications, and quality of analgesia. Pain intensity at rest was assessed by using a 10-point linear visual analog scale (VAS; 0 = no pain, 10 = the worst pain imaginable). If necessary to provide satisfactory analgesia, the investigator increased the infusion rate of fentanyl by 0.5 mL/h and administered additional 13 mL boluses in an attempt to achieve a pain score of <3. A decision to decrease the hourly dose was made jointly by the patient and the investigator. If no PCA requests had been made and no rescue doses had been needed during the preceding 4-h interval, the investigator offered to reduce the infusion rate by 0.5 mL/h. If the patient refused, the hourly dose was not reduced. The patients were assessed for incidence of any pruritus, facial pruritus (as indication of rostral opioid spread), sedation, nausea, vomiting, backache, urinary retention, and uncomfortable uterine cramping. The severity of pruritus and sedation was assessed using a 10-point scale (0 = none, 10 = worst imaginable). At the patients request, severe pruritus or severe sedation was treated by administering increments of IV naloxone 0.04 mg until relief was achieved. Nausea and vomiting were treated by administering IV metoclopramide 10 mg. Time to resume a liquid diet, as well as the time to pass flatus, duration of urethral catheterization, and duration of hospitalization were recorded. The incidence of side effects indicates the number of patients in whom the side effect occurred regardless of duration or the number of time intervals during which it occurred. Motor block was assessed using a score modified from that described by Bromage (13), (1 = complete block, unable to move feet or knees; 6 = able to perform partial knee bend while standing).
Patients received no additional systemic opioids, nonsteroidal analgesics or sedatives during treatment. Each patient had IV access throughout. Blood pressure, pulse, respiratory rate and adequacy of respiration were monitored every 12 h by a nurse during the treatment. Twelve hours after surgery, if patients demonstrated normal leg strength (Modified Bromage score at least 5), an attempt was made to let the patient ambulate. Heart rate and blood pressure were measured by nurses before and 2 min after the start of each ambulation to assess orthostatic hypotension, defined as a decrease in systolic blood pressure 20% from baseline, and bradycardia, defined as a heart rate less than 60 bpm. Symptoms of dizziness, nausea, or vomiting were also recorded. Nurses were instructed not to allow any patient with evidence of hypotension, bradycardia, or dizziness to ambulate. Overall satisfaction with treatment was assessed at the termination of treatment by using a 10-point VAS (0 = no satisfaction, 10 = best satisfaction). Breast-fed neonates were assessed at 1 h and 48 h of life by a pediatric nurse practitioner blinded to the solution administered, using the Neurologic and Adaptive Capacity Score (14).
Concentration of fentanyl was measured in samples of blood and/or colostrum obtained from patients arbitrarily selected from each group. Blood was drawn from an antecubital vein of the arm contralateral to the one with an IV line at 0, 24, and 48 h of the epidural infusion. Colostrum samples were collected at 24 and 48 h of the epidural infusion and shortly before discharge from the hospital. Colostrum samples and (after centrifuging blood) plasma samples were stored at -20°C until analysis. Plasma and colostrum concentrations of fentanyl were determined using a radioimmunoassay kit (Diagnostic Products Corporation, Los Angeles, CA) for both plasma and colostrum. The assay has a limit of detection of 0.1 ng/mL and intra- and interassay coefficients of variation were 3.3%4.0% and 4.9%6.7% respectively.
Statistical Analysis
Data are presented as mean ± SD except for side effects, which are expressed as incidence. Data measured over time were analyzed by repeated-measures analysis of variance and overall differences between groups were assessed by contrasts. Data expressed as an average or sum of all values obtained during the 48 h of the study were analyzed by analysis of variance with a Bonferroni/Dunn post hoc test. Categorical variables were analyzed by using Fishers exact test or
2 as appropriate. Data from the few patients who did not complete the study were excluded from analyses that required summation of data over time, but were otherwise included throughout their period of participation. Data that were not normally distributed were log transformed before analysis. A P value of <0.05 was considered significant.
| Results |
|---|
|
|
|---|
The mean fentanyl infusion rate during successive intervals of the 48-h study was less among patients in Group I-BeFe (Fig. 1, P < 0.001) than among patients in the other three groups and less among patients in Group IV-SeFe compared with those in Group II-BeFi and Group III-SeFi (P < 0.001). The mean infused dose and total dose of fentanyl during the 48 h of the study were less among patients in Group I-BeFe (Table 1, P < 0.02) compared with all other patients and were more among patients in Groups II-BeFi and III-SeFi than among those in Group IV-SeFe (Table 1, P < 0.05). Total PCA attempts during the 48 h study were more among patients in Group III-SeFi than Groups I-BeFe and II-BeFi (Table 1, P < 0.05). However, actual doses delivered from the PCA device did not differ among the groups.
|
|
|
|
For breast-fed babies, there were no differences among treatment groups with respect to mean neonatal adaptive or neurologic capacity or cumulative scores at either 1 or 48 h of life. The cumulative scores at 1 and 48 h were 37.3 ± 2.3 and 39.2 ± 0.8, 38.2 ± 1.5, and 39.4 ± 1.4, 37.6 ± 1.8 and 39.5 ± 0.8, 37.8 ± 1.7, and 38.8 ± 1.5 for Group I (n = 9), II (n = 8), III (n = 13), and IV (n = 11) respectively.
Plasma concentrations of fentanyl are shown in Table 3. Fentanyl plasma concentrations were larger in patients receiving fentanyl IV (Group II-BeFi and Group III-SeFi) than among patients receiving fentanyl epidurally (Group I-BeFe and Group IV-SeFe, P < 0.001) at 24 and 48 h of the study. It was not possible to analyze statistically the data for concentration of fentanyl in colostrum because parturients were not able to repeatedly express sufficient colostrum for analysis. Fentanyl concentrations in colostrum ranged from not detectable to 5.5 ng/mL. The greatest observed values were as follows: Group I, 1.8 ng/mL; Group II, 4.8 ng/mL; Group III, 5.5 ng/mL; and Group IV, 3.1 ng/mL.
|
| Discussion |
|---|
|
|
|---|
We had anticipated that 20 µg/mL fentanyl administered IV at an initial infusion rate of 40 µg/h and augmented by patient 20 µg PCA dose or investigator 2060 µg additional administered boluses would provide satisfactory analgesia and still permit us to differentiate the efficacy of analgesia in the four groups. However, this dose was barely satisfactory for the IV fentanyl groups (Groups II-BeFi and III-SeFi). Although the mean pain score for these groups was near our target score of <3, these groups reported scores as high as 5 or 6 during the early hours of the study before adjustments of flow rate were made. Despite this, no patient in any group dropped out of the study because of inadequate pain relief. Increasing the IV fentanyl infusion rate or adding rescue doses did not improve patient satisfaction. Much to the contrary, faster infusion rates were associated with more opioid-related side effects.
A local anesthetic-sparing effect of fentanyl used for labor pain was demonstrated in two recent studies using fentanyl administered as constant amounts epidurally or IV and bupivacaine administered into the epidural space as the variably administered solution (10,11). Both groups of investigators concluded that epidural fentanyl used in a nonsurgical obstetric population acted primarily by a spinal mechanism. Our results extend these conclusions to an obstetric population recovering from cesarean surgery and show that administration of fentanyl and bupivacaine together in the epidural space is associated with an opioid-sparing effect that is not observed in the presence of the same amount of epidural bupivacaine when fentanyl is administered IV. We further show that these effects persist for at least 48 h and are associated with less sedation and lower fentanyl plasma levels.
Although we have limited our conclusions with respect to the primary mechanism of action of epidural fentanyl to the population studied, they may be generally applicable. Studies comparing epidural and IV infusions of fentanyl for postoperative pain in nonobstetric as well as obstetric patients have found no differences between the two routes of administration with regard to serum fentanyl concentrations, side effects, or quality of analgesia and have concluded that the mechanism of epidural fentanyl analgesia was mostly related to its systemic absorption and a supraspinal effect. Some of these studies administered the fentanyl necessary for adequate analgesia using initial epidural infusion rates of 27 mL/h (57,9). We believe that, in contrast to our study, these studies used diluent volumes of epidural fentanyl that were too small. The epidural efficacy of fentanyl is dependent on the use of an adequate dilutional volume (18,19). We believe that to compensate for inadequate dermatomal spread, these studies used concentrations of fentanyl large enough to result in systemic absorption sufficient to produce analgesia by a supraspinal mechanism. Other studies used adequate diluent volumes but differed from our study in using substantially larger concentrations of fentanyl than we used (4,8). The administration of large amounts of fentanyl epidurally, regardless of diluent volume, will result in systemic absorption of sufficient drug to produce therapeutic blood levels and thereby obscure the differences between epidural and systemic administration or between various epidural diluent volumes and systemic administration. In our study we used the smallest amount of fentanyl that we knew from our prior clinical experience would provide adequate comfort for our patients. The administration into the epidural space of IV-size doses of fentanyl negates the advantages of using this route.
In conclusion, our data support the growing body of evidence that epidural fentanyl analgesia occurs primarily by a spinal mechanism and our data further show that the enhancement of fentanyls efficacy by very small dose epidural bupivacaine and epinephrine requires an interaction of these drugs at the spinal level.
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
J. Gadsden, S. Hart, and A. C. Santos Post-Cesarean Delivery Analgesia Anesth. Analg., November 1, 2005; 101(5S_Suppl): S62 - 69. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Ginosar, E. T. Riley, and M. S. Angst The Site of Action of Epidural Fentanyl in Humans: The Difference Between Infusion and Bolus Administration Anesth. Analg., November 1, 2003; 97(5): 1428 - 1438. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Ginosar, M. O. Columb, S. E. Cohen, E. Mirikatani, M. S. Tingle, E. F. Ratner, M. S. Angst, and E. T. Riley The Site of Action of Epidural Fentanyl Infusions in the Presence of Local Anesthetics: A Minimum Local Analgesic Concentration Infusion Study in Nulliparous Labor Anesth. Analg., November 1, 2003; 97(5): 1439 - 1445. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Joris, E. A. Jacob, D. I. Sessler, J.-F. J. Deleuse, A. Kaba, and M. L. Lamy Spinal Mechanisms Contribute to Analgesia Produced by Epidural Sufentanil Combined with Bupivacaine for Postoperative Analgesia Anesth. Analg., November 1, 2003; 97(5): 1446 - 1451. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nitahara, M. Matsunaga, K. Katori, H. Yotsui, H. Higuchi, and K. Higa Effect of continuous low-dose intravenous diltiazem on epidural fentanyl analgesia after lower abdominal surgery Br. J. Anaesth., April 1, 2003; 90(4): 507 - 509. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|